COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 11,1997 PSA#1990Department of the Interior, U.S. Geological Survey, 345 Middlefield
Road,Mail Stop 285, Menlo Park, CA 94025-3591 99 -- DRILLING OF TEST HOLE AND INSTALLATION OF MONITORING WELL(S) DUE
011298 POC Richard C. Schwaberow, Contracting Officer, (650) 329-4171,
fax (650) 329-5517 PROCESS TO POINT OF AWARD PENDING AVAILABILITY OF
FUNDS The U.S. Geological Survey (USGS) Menlo Park, California has a
requirement for drilling of test hole and installation of monitoring
well(s) near Fallon, Nevada in Churchill County. The purpose of the
test hole and wells is to obtain geologic, water level and water
chemistry data at different depths in and near the Fallon basalt
aquifer. The upper portion of the hole will be drilled through
approximately 400 feet of basin-fill sediments (gravel, sand, silt and
clay) overlying the basalt aquifer. The lower portion of the hole will
be drilled through the basalt and possibly into an underlying
sedimentary aquifer. The thinkness of basalt aquifer to be drilled is
decribed by three alternative test hold and well designs (contained in
the Statement of Work). The holes and permanent steel casing shall be
of minimum diameter to meet Nevada State Regulations and allow test
hole drilling and installation of monitoring wells, as described by the
Alternatives (contained in the Statement of Work)., constructed of 2
inch diameter, flush-joint threaded Schedule 80 PVC casing and screen
at specified depths and emplacement of gravel pack near screened
intervals and bentonite grout between screened intervals using a tremie
pipe. Listed diameters are suggested minimum nominal values. Nevada
State Regulations require the test hole to be 4 inches greater than the
diameter of a single casing, or the combined diameter of multiple
casings. A Site Visit is scheduled for December 29, 1997, 10:00AM PST.
Prospective bidders must contact the COR Representative Doug Mauren at
(702) 887-7631 to ensure that they will be attending the site visit.
This must be done prior to 5:00pm PST on December 23, 1997. The on-site
driller shall be licensed by the State of Nevada as a well driller. All
work shall conform to applicable state and local requirements. Water
and electrical power are not available at the site. Exact location is
contained in the Statementof Work. Request for quotation and applicable
(FAR) Federal Aquisition Regulations along with the statement of work
(SOW) will be provided to prospective bidders prior to the site visit
by contacting the Contracting Officer prior to 3:00pm, PST, December
19, 1997 (0342) Loren Data Corp. http://www.ld.com (SYN# 0290 19971211\99-0001.SOL)
99 - Miscellaneous Index Page
|
|