COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 18,1997 PSA#1995NASA/George C. Marshall Space Flight Center, Procurement Office,
Marshall Space Flight Center, AL 35812 66 -- ULTRAVIOLET-VISIBLE-NEAR INFRARED SPECTROPHOTOMETER SOL
8-1-8-10-B7724 DUE 122497 POC June N. Blackwell, Contract Specialist,
Phone (205) 544-0351, Fax (205) 961-0059, Email
june.n.blackwell@msfc.nasa.gov -- Carlos M. Smiley, Contracting
Officer, Phone (205) 544-0355, Fax (205) 544-9080, Email
carlos.smiley@msfc.nasa.gov WEB: Click here for the latest information
about this notice,
http://procurement.nasa.gov/EPS/MSFC/date.html#8-1-8-10-B7724. E-MAIL:
June N. Blackwell, june.n.blackwell@msfc.nasa.gov. In accordance with
Note 22, NASA/MSFC plans to issue a Request for Quotation (RFQ) to
Perkin Elmer; 761 Main Ave., MS 243; Norwalk, CT 06859 for the
following requirement: SPECIFICATIONS: NSN = 6630 1. P/N = Supply
Source = LAMBDA 900 UV-VIS-NIR-SPECTROMETER AND OPERATING SOFTWARE
PERKIN-ELMER CATALOG #BV900NDO. DOUBLE BEAM, DOUBLE MONOCHROMATOR RATIO
RECORDING UV/VIS/NIR SPECTROMETER WITH MICROCOMPUTER ELECTRONICS,
CONTROLLED BY DEC PC OR COMPATIBLE PERSONAL COMPUTER. OPTICAL SYSTEM OF
THE SPECTROMETER -- ALL REFLECTING OPTICAL SYSTEM {SIO2 COATED}, WITH
HOLOGRAPHIC GRATING MONOCHROMATOR WITH 1440 LINES/MM UV/VIS AND 360
LINES/MM IN NIR; LITTROW MOUNTING, SAMPLE THICKNESS COMPENSATED
DETECTOR OPTICS; PREALIGNED TUNGSTEN-HALOGEN AND DEUTERIUM SOURCES,
PHOTOMULTIPLIER R955 FOR HIGH ENERGY IN THE WHOLE UV/VIS WAVELENGTH
RANGE, PELTIER COOLED PBS DETECTOR FOR NIR. WAVELENGTH RANGE-185-3300
NM WITH N2 PURGING DOWN TO 175 NM; STRAY LIGHT -- -<0.00008% T AT
220, 340, & 370 NM MEASURED ACCORDING TO ASTM E-387; 1% ATTENUATOR IN
REFERENCE BEAM. <0.0015% T AT 1690 NM WITH CHC13, 4 CM PATH-LENGTH
. <0.0005% T AT 2365 NM WITH CHC13, 1 CM PATHLENGTH; WAVELENGTH
ACCURACY-+/- 0.08 NM UV/VIS, +/- 0.30 NM NIR; WAVELENGTH
REPRODUCIBILITY -<0.02 NM, UV/VIS RANGE, < 0.08 NM NIR STANDARD,
<0.008 NM UV/VIS & 0.04 NM NIR RANGE, STANDARD DEVIATION FOR 10
MEASUREMENTS; BANDPASS RANGE-0.05 TO 5.00 NM IN 0.01 NM INCREMENTS
UV/VIS, 0.2 TO 20 NM NIR RANGE IN 0.04 NM INCREMENTS, FIX RESOLUTION,
CONSTANT ENERGY OR SLIT PROGRAMMING; PHOTOMETRIC RANGE-+/- 6A;
PHOTOMETRIC LINEARITY-BETTER THAN 1% AT 3 ABSORBANCE MEASURED WITH
ADDITIVE GRAY GLASSES; PHOTOMETRIC ACCURACY-+/- 0.003A OR 0.08% T AT
1A, +/-0.003A OR 0.05% T AT 0.6A, MEASURED WITH NIST FILTER 930D;
PHOTOMETRIC REPRODUCIBILITY -- -<0.0008A STANDARD DEVIATION AT 1A
USING NIST 930D FILTER AT 546.1 NM, 2 NM SLIT AND 2 SEC INTEGRATION.
This procurement is being conducted under the Simplified Acquisition
Procedures (SAP). The SIC code and the smallbusiness size standard for
this procurement are 3826 and 500, respectively. The quoter shall
state in their quotation their size status for this procurement. Any
refereced notes can be viewed at the following URL:
http://genesis.gsfc.nasa.gov/nnotes.htm. The Government intends to
acquire a commercial item using FAR Part 12. Interested firms have
until December 22, 1997, to submit in writing to the identified point
of contact, their qualifications/capabilities. Such
qualifications/capabilities will be used solely for the purpose of
determining whether or not to conduct this procurement on a competitive
basis. Responses received after December 22, 1997, or without the
required information will be considered nonresponsive to the synopsis
and will not be considered. A determination by the Government to not
compete this proposed effort on a full and open competitive basis,
based upon responses to this notice is solely within the discretion of
the Government. Oral communications are acceptable in response to this
notice. All responsible sources may submit an offer which shall be
considered by the agency. An Ombudsman has been appointed. See Internet
Note "B". (0350) Loren Data Corp. http://www.ld.com (SYN# 0289 19971218\66-0013.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|