Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 23,1997 PSA#1998

Naval Research Laboratory, Attn: Code 3230, 4555 Overlook Avenue, SW, Washington, DC 20375-5326

C -- COMPREHENSIVE ENERGY AND WATER AUDIT FOR ALL NRL OWNED BASE SUPPORT BUILDINGS AT THE NAVAL RESEARCH LABORATORY, WASHINGTON, DC SOL N00173-98-R-MN06 POC Contact, Contract Specialist, Michelle Nicholl,Code 3230.NM, Contracting Officer, Carol Parnell, (202) 767-4597 WEB: click here to download a copy of the RFP, http://heron.nrl.navy.mil/contract/home.htm. The Naval Research Laboratory has a requirement for architectural and engineering servicesnecessary to procure comprehensive energy and water audits that shall involve verification, inspection, testing, evaluation, and analysies of building systems, utility distribution systems, and building envelopes at the Naval Research Laboratory, Washington, D.C. Award is anticipated to be made in March 1998. The period of performance of this contract will be 27 weeks from the date of contract award.The work includes, but is not limited to, the A/E providing all engineering services necessary for the preparation of a comprehensive energy study and water audit for all Naval Research Laboratory owned base support buildings located at the Naval Research Laboratory, Washington D.C. site. The 27 base support buildings contain 391,669 sq. ft.. The A/E shall identify Energy Conservation opportunities (ECOS) and develop these into Energy Conservation Projects (ECPs) for funding including preparing project documentation. Comprehensive Energy and Water procedures shall comply with requirements of Executive Order 12902. It is estimated that the price range for this requirement is between $25,000 to $100,000. A firm fixed price contract is anticipated. Responding firms will be evaluated in the following areas: 1) Professional qualifications necessary for satisfactory performance of required services; 2) Specialized experience and technical competence in the type of work required; 3)Capacity to accomplish the work in the required time; 4) Past performance on contracts with Government agencies and private industry in terms of cost control, quality of work, and compliance with performance schedules; 5) Location in the general geographic area of the project. provided, that application of this criterion leaves an appropriate number of qualified firms, given the nature and size of the project; 6) Demonstrated success in prescribing the use of recovered materials and achieving waste reduction and energy efficiency in facility design; 7) Volume of work previously awarded by Department of Defense. Send SF-254's and SF-255's to Contracting Officer, ATTN: Code 32, Naval Research Laboratory, 4555 Overlook Ave. S.W., Washington DC 20375-5326; Telefax 202-767-5896 or 202-767-6197. All responsible sources may submit SF-254's and SF-255's which shall be considered by the agency. SYNOPSIS MN06 . Note 24 & 26 (0353)

Loren Data Corp. http://www.ld.com (SYN# 0023 19971223\C-0006.SOL)


C - Architect and Engineering Services - Construction Index Page