A -- 5 KW GERNERATOR SET SOL F04606-98-R-9998 DUE 040298 POC For copy, contact the info office indicated., For additional information contact Gray.5ag/Pkl-1/[916]643-0500 This is a sources sought synopsis for a 5 kW, 60 Hz, A/C, portable diesel engine driven generator set. For aditional information contact Lew Gray, PKL-1, (916) 643-0500, fax: (916) 643-6767. Item 0001, NSN 6115, part number and quantities to be determined. The Air Force eventually intends to establish a multiple year requirements type contract for this unit. The generator set shall be rated at 0.8 power factor and shall supply 120 V 1-phase 2 wire and 120/240 1-phase 3 wire AC voltages at 4000 feet. This generator set shall meet the additional performance requirements: (1) __ __ __ __ __ __ __ __ __ __ __ __ Altitude degradation (4000 -- 10000 ft), 3.5% per 1000 ft, (2) Climatic conditions: minus 25 degrees F (-31.7 degrees C) to plus 140 degrees F (+60.0 degrees C), (3) Voltage waveform deviations (max): 6%, (4) Single voltage harmonic: 3%, (5) Voltage modulation (ma) 2.5%, (6) Voltage regulation (max): 3% (7) Short term voltage stability (30 sec):+/- 2% bandwidth, (8) Long term voltage stability (4 hrs): +/- 4% bandwidth, (9) Dip and rise for rated load (max) 20% recovery time: 3 sec, (10) Dip for low power factor load (max) 35% no-load voltage recovery time: 5 sec to 95% of no-load voltage, (11) Voltage adjustment range: 120 V connection: 114- 126 V 120/240 V connection: 228-252 V, (12) Frequency regulation: 3%, (13) Short term frequency stability (30 sec): +/- bandwidth, (14) Long term frequency stability (4 hr): +/- 3% bandwidth, (15) frequency undershoot w/load change (max): 3% recovery time: 3 sec, (16) Frequency overshoot w/load change (max): 4% recovery time: 3 sec, (17) Frequency adjustment range: +/- 3. The following general specifications are required: (18) __ __ __ __ __ __ __ _&llmdash; __ __ __ __ __ __ __ ____ Structure: aluminum housing and tubular frame, (19) Maximum dimensions: 24 inches wide: 36 inches long; 26 inches high, (20) Maximum weight: 350 pounds dry weight (21) Finish: olivedrab green, code 34079, table V Federal-Standard-595, using a VOC compliant coating, (22) Transportability: transportable by airplane in acordance with military standard-1791, M35 or M0880 truck or equivilant in accordance with military manual-8090 for type V mobility, (23) Fuel: multi-fuel capabile: JP-8 turbine fuel primary, alternates: DF-A, DF-B, DF-034 and DF-35 diesel fuel without manual adjustment to generator or drive engine required when operating on alternate fuel (s), (24) Fuel capacity: internal fuel capacity to enable 8- 9 hours operation under full load at 0.8 power factor and capable of refueling without engine shut down, (25) Filters: reusable oil filters, fuel filter and air filtes will be used, (26) Oil: operate a minimum of 30 continuous days under full load without the need of an oil change, ((27 Voltage connections: 120 V, 2 wire, 1-phase; 240 V, 2 wire, 1-phase, (28) Noise level: 70 dba @ 7 meters, (29) Protective devices: short circuit protection which interrupts power output within 5 cycles after being manually activated. Low oil warning light with automatic shutdown device shall be provided, (30) Instrumentation: voltmeter, frequency meter, percent-of-load meter (ammeter) and fuel quantity, (31) Electromagnetic interface:suppressed to military standard-461 limits. The following enviornmental requirements are esential and shall be met: (32) Add on systems may be utilized to extend ambient temperature limits to -65 degrees F (-53.9 degrees C) to 140 degrees F (+60.0 degrees C), (33) Protection from 5.2 inches of rain per hour impinging on the set at angles from vertical up to 15 degrees from vertical in all directions, (34) Protection from winds up to 65 MPH and two inches of ice on all exposed surfaces, (35) Protection from blowing sand with velocities up to 65 MPH with particles up to 1000 microns in diameter and concentrations to 2.19 grams per cubic meters and dust with velocities up to 20 MPH with particles up to 1000 microns in diameter and concentrations to 10 +/- 7 grams per cubic meter, (36) Generator must start and operate without winterization within 5 minutes at ambient temperatures from: -25 degrees F (-31.7 degrees C) to +140 degrees F (60.7 degrees C) at all possible humitity levels, (37) Shock and rough handling: 10 MPH railroad impact, 3 foot drop, and vibration stresses during its service use and shipment by land sea and air, (38) Generator must operate level or inclined no more than 8 degrees from level, (39) The generator set shall meet 1997 EPA requirements for non-road engines, (40) The tubular frame configuration shall allow generator set to be lifted by a four person team. The generator set manufacturer shall be the original equipment manufacturing company. The company must have manufactured and supplied diesel engine generator sets to commercial industries with tracable records within the last five years. The generator set must have a proven reliability and should have a mean time between failures of 500 hours or better. The generator set manufacturer must have a proven tracable logistics support system in place for spare/repair parts, maintenance and service. Original Equipment Manufacturers shall provide data sheet (s) with their model selection that meets our requirements to the contracting officer: Attn. Lew Gray, 5040 Dudley Blvd., McClellan AFB CA 95652-1390. Point of contact for technical or engineering questions is John W. Money, LIEE, (916) 643-3826 x538. THIS IS A SOURCES SOUGHT SYNOPSIS. NO DETAILS ARE AVAILABLE AS TO WHEN OR HOW THIS INQUIRY FOR INFORMATION WILL DEVELOPE INTO AN ACTUAL REQUIREMENT. The approximate required delivery date of the requested information is on or before 10 Feb The approximate issue/response date will be 02 Mar 98. See Note (s) 25. (0010)

Loren Data Corp. http://www.ld.com (SYN# 0016 19980114\A-0016.SOL)


A - Research and Development Index Page