COMMERCE BUSINESS DAILY ISSUE OF JANUARY 23,1998 PSA#2017United States Postal Service, Major Facilities Office, 225 North
Humphreys Blvd, Memphis, TN 38166-0300 C -- PENSACOLA, FL, P&DC, AND TALLAHASSEE, FL, P&DF, DESIGN/BUILD
EXPANSIONS SOL 475450-98-A-0029 DUE 030598 POC Rita Williams-Humphrey,
Purchasing Specialist, FAX 901/747-7408 WEB: U. S. Postal Service,
www.usps.gov. E-MAIL: U. S. Postal Service, jraley2001@aol.com. These
projects consist of furnishing manpower, materials, equipment, and
supervision necessary to performed one or two Design/Build Expansions
at the following locations: Processing and Distribution Center (P&DC),
1400 West Jordan Street, Pensacola, FL 32501-9998, and Processing and
Distribution Facility (P&DF), 2800 South Adams Street, Tallahassee, FL
32301-9997, in accordance with plans and specifications. Design/Build
Contractors may submit proposals on one or both projects/locations. One
or two fixed price contract(s) to Design/Build the expansions will be
awarded to one or two contractors whose proposal(s) are most
advantageous to the Postal Service. The expansion for Pensacola P & D
C is as follows: Complete the Design and Construction of a 31,235 gross
sq. ft. building expansion as per the
guidelines/drawings/specifications/applicable codes. Demolition of an
existing retaining wall, and installation of a new retaining wall.
Rework the existing parking/storm drainage/site lighting at the west
end of the site. The facility shall remain fully operational at all
times. Phasing of the work will be necessary. The building expansion
will be a concrete slab, a steel structure, metal insulated deck with
a modified bituman roof, brick veneer and synthetic stucco backed by
concrete block. The expansion for Tallahassee P & D F is as follows:
Complete the Design and Construction of: a 30,077 gross sq. ft.
building expansion as per the
guidelines/drawings/specifications/applicable codes. Demolition of
existing paving/site lighting/platform, removal of trees, and
installation of a new detention pond/paving/platform/canopy, and
reworking the storm drainage/site lighting. The facility shall remain
fully operational at all times. Phasing of the work will be necessary.
The building expansion will be a concrete slab, a steel structure,
metal insulated deck with a modified bituman roof, and synthetic stucco
backed by concrete block. Both facilities are USPS owned and will be
expanded onto USPS owned property. Offerors will be required to submit
both technical and price proposals. Technical submittals will require
evidence of: (1) Experience; (2) Management Plan; (3) Financial
Capability; and (4) Organization. Time of completion for both
facilities is 270 calendar days after notice to proceed, to include
both design and construction. The scopes of work are further defined in
the drawings and specifications. The Total estimated cost for
Pensacola, Florida, is between $2,700,000 and $3,200,000. The Total
estimated cost for Tallahassee, Florida, is between $2,500,000 and
$3,000,000. Return date for the above projects is March 5, 1998. To
view the site at Pensacola, Florida, contractors/suppliers are invited
to call Mr. Howard R. Stillwell, Manager, In-Plant Support, Processing
& Distribution Center, 1400 West Jordan Street, Pensacola, FL
32501-9998, Telephone No. 850/434-9197. To view the site at
Tallahassee, Florida, Contractors/Suppliers are invited to call Mr.
Gerald L. Johnson, Plant Manager, 2800 South Adams Street, Tallahassee,
FL 32301-9996, Telephone No. 850/216/4214. However, formal pre-proposal
Conferences and walk throughs are scheduled as follows: February 5,
1998,at 1:00 p.m. (Conference Room) Pensacola, Florida. February 6,
1998 @ 9:30 a.m., (Conference Room) Tallahassee, Florida. A walk
through will take place immediately after each Conference. If you
desire plans and specifications for one or both of these projects,
please send your request, along with your fee remittance amount of $100
per set, for each location made payable to Rapid Reproductions, to:
Rapid Reproductions, Attn: USPS, 5300 Pleasant View Rd., Memphis, TN
38134-6414, Telephone number 901/388-6268, FAX number 901/385-2670. To
expedite, FAX a copy of check or money order before mailing. If FAX is
received before 1 p.m. on a given day, the plans and specs will be
mailed that day via two/three-day priority mail. If you wish them
overnighted, send an additional $50 for each set or $100 for both
location requested. Both sets cost $100 per set or $200 for both
location. Plans will also be available for your inspection at the
following locations: (1) The PENSACOLA, FLORIDA, LOCATION from Mr.
Howard R. Stillwell, Manager, In-Plant Support, Processing &
Distribution Center, 1400 West Jordan Street, Pensacola, FL 32501-9998,
Telephone No. 850/434-9197. (2) The TALLAHASSEE, FLORIDA LOCATION, from
Mr. Gerald L. Johnson, Plant Manager, 2800 South Adams Street,
Tallahassee, FL 32301-9996, Telephone No. 850/216/4214. (3) Local Plan
Rooms. (4) W. Dodge, Inc. This is a negotiated procurement; therefore,
offers will not be publicly opened. AWARD OF CONTRACT(S) IS SUBJECT TO
APPROVAL OF FUNDS BY THE AREA OFFICE. NOTE: ORDER ONLY VOLUMES 1, 2,
& 3 IF YOU ARE ONLY INTERESTED IN THE PENSACOLA, FL, PROJECT. ORDER
VOLUMES 1, 2, AND 4 IF YOU ARE ONLY INTERESTED IN THE TALLAHASSEE, FL
PROJECT. ORDER ALL FOUR (4) VOLUMES IF YOU ARE INTERESTED IN BOTH
PROJECTS. cbdpens&tallah.doc (q nco des/bld). (0021) Loren Data Corp. http://www.ld.com (SYN# 0035 19980123\C-0004.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|