Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JANUARY 27,1998 PSA#2019

Procurement Division, Naval Air Station Oceana, Supply Dept. Bldg 730, Virginia Beach, VA 23460-5120

54 -- PREFABRICATED METAL CRYOGENIC BUILDING SOL N60191-98-Q-0004 DUE 021198 POC d. capps 757-433-2361 fax 757-433 WEB: n60191-98-q-0004, cbdnet.gpo.gov/ACCEPT.template. E-MAIL: vwhite@series2000.com, dcapps@livenet.net. DESC: The Naval Air Station Oceana in Virginia Beach, VA is soliciting bids for a preengineered metal cryogenic building. Design building for following loads: Live loads 25 PSF, Wind loads 114 MPH Min, Collateral Loads 5 PSF. Building will have the following dimensions: Width 40', Length 100', Height 12', Bay Spacing 20' 1) Preengineered metal building Catalog Data. 2) Shop drawings for preengineered metal building. 3) Template for anchor bolts. 4) Design data for building including foundation loads, anchor bolts, perlins and gifts and bracing design calculations for the entire building, stamped by a professional engineer. WARRANTIES: PROVIDE WARRANTY FOR WEATHERTIGHTNESS AND WARRANTY FOR PANEL FINISH FOR A PERIOD OF 20 YEARS PREFORMED WALL AND ROOF PANELS: MINIMUM 26 GAUGE GALVALUME SUBSTRATE W/INTEGRAL FASTENERS AND 70% "KYNAR 500" STANDARD COLOR FINISH TO MATCH NAS OCEANA "INTRUDER WHITE" (BUTLER-COTE "STONE WHITE" OR AMERICAN BUILDINGS "LIGHT STONE"). PROVIDE MATCHING GUTTERS, DOWNSPOUTS, HANGARS, STRAPS, GABLE AND EAVE TRIM, AND RAKE FLASHINGS. PROVIDE CLOSURE STRIPS PREMOLDED TO MATCH CONFIGURATION OF THE COVERING. PROVIDE ALL CONNECTORS AND SEALANTS NECESSARY FOR WEATHERTIGHTNESS. PROVIDE VINYL FACED BLANKET TYPE FIBER-GLASS WALL AND ROOF INSULATION. THICKNESS SHALL BE R-11 FOR THE WALLS AND 4-19 FOR THE ROOF. EXTERIOR DOORS, FRAMES, AND HARDWARE: PERSONNEL DOORS: 3'-0"X7'0"X1-3/4", INSULATED 16 GAUGE FLUSH HOLLOW -METAL DOORS AND FRAMES. HARDWARE SHALL BE PROVIDED FOR ALL DOORS TO PROVIDE THE PROPER OPERATION AND TO BE IN COMPLIANCE WITH LOCAL CODES. HARDWARE WILL INCLUDE HINGES, CLOSERS, LOCKSETS, THRESHOLDS, AND DOOR STOPS. -OVERHEAD DOORS: 10'-0" WIDE BY 10'-0" HIGH, INSULATED, MANUALLY OPERATED SECTIONAL OVERHEAD DOORS. THE INSULATION SHALL BE FACTORY INSTALLED POLYURETHANE CORE R-13 OR BETTER. DOORS SHALL BE IN COMPLIANCE WITH LOCAL CODES AND INCLUDE FRAME AND ALL NECESSARY HARDWARE. PROVIDE THREE ROOF CURBS WITH PREENGINEERED BUILDING FOR ROOFTOP EXHAUST FAN. PROVIDE AND INSTALL ROOFTOP EXHAUST FAN. (0022)

Loren Data Corp. http://www.ld.com (SYN# 0194 19980127\54-0001.SOL)


54 - Prefabricated Structures and Scaffolding Index Page