COMMERCE BUSINESS DAILY ISSUE OF JANUARY 27,1998 PSA#2019Federal Aviation Administration, 601 E. 12th St., ACE-55, Room 1524,
Kansas City, MO 64106 Y -- ESTABLISHMENT OF QUALIFIED VENDOR LIST (QVL), CONSTRUCTION
PROJECTS #1, CENTRAL REGION (KS, IA, NE, MO) SOL QVL-SIR DUE 020698 POC
Susan Chasteen, (816) 426-7312, Carrie Coffman, (816) 426-2642 WEB: FAA
Central Region Procurement Announcements,
http://www.tc.faa.gov/cen/ace_55_2.htm. E-MAIL: QVL-SIR, Qualified
Vendor List, susan.chasteen@faa.dot.gov. You may request a copy of the
Screening Information Request (SIR) by mail (DOT, Federal Aviation
Administration; ACE-55/QVL SIR; 601 E. 12th Street, Room 1524; Kansas
City, Missouri 64106), by fax (816-426-3103) or by the Internet
(Susan.Chasteen@faa.dot.gov.) The Federal Aviation Administration
(FAA), Central Region, plans to establish a QVL of Prime Contractors
that may be used for the following types of recurring construction
projects: Runway End Identifier Lights (REIL); Visual Approach Slope
Indicator (VASI); Precision Approach Patch Indicator (PAPI); Runway
Visual Range (RVR); Non Directional Beacon (NDB); Distance Measuring
Equipment (DME); Glide Slope (GS); Localizer (LOC); Medium Intensity
Approach Lighting System with Runway Alignment Indicator Lights
(MALSR); Approach Light System with Sequence Flasher (ALSF-2);
Instrument Landing System (ILS); Low-Level Windshear Alert System
(LLWAS); Engine Generator (E/G); Markers, Electrical, Cable Loop, Site
Restoration/Demolition and Facility Restoration. Contractors placed on
the QVL will be expected to perform at least 15% of the on-site
physical work and they will be required to perform work in all four
states covered by the Central Region (Iowa, Nebraska, Kansas and
Missouri) To be considered for the QVL a firm must be able to perform
all of the following types of work through normal business practices:
Clear, grub, grade, excavate and fill project site for new facility.
Furnish competent surveying resources to properly layout the subject
site and provide and vertical control. Install crushed rock access
roads, concrete access roads and surfaced facility plots to the grades
and elevations indicated. Work includes installation of geotextile
membranes and soil sterilants. Install reinforced concrete foundations
and footings for equipment shelters or buildings, transformers,
electrical equipment, LIR poles, elevated steel, manholes and
handholes, etc. as shown per contract drawings. Work includes
embedments and knockouts. Install individual spread footings, pier
footings, grade tie beams, etc. for the various types of foundations.
Install earth electrode grounding system, building grounding, and
lightning protection systems complete with material and hardware. Work
includes interconnections to a shelter or building grounding system.
Install all required cable ladders, cable trays, wireways, conduits,
fitting, motors, transformer, lights, receptacles, miscellaneous
electrical equipment, etc. as required. Trench and install underground
or exposed power, control, signal and fiber optic cables. Work
includes boring under taxiways, splices, handholes, manholes and
termination's. Install government furnished materials and ensure the
equipment and materials are interconnected in a proper working order.
Complete all caulking and sealing of equipment, buildings, wall
penetrations, etc. in order to make watertight and weatherproof.
Install and maintain erosion control measures to protect ditches,
inlets and facility plot layouts. Provide obstruction markingas
required to meet FAA and the local Airport Authority requirements.
Furnish temporary utility connections which may include electrical,
water, and gas. Establish and maintain safety plan work within the
Airport Operations Areas. Implement and maintain a quality control plan
to ensure contract compliance. Conduct all required tests and checks to
verify contract compliance. Restore all site conditions to original
conditions when required. This requirement was previously advertised on
May 6, 1997. Due to a change in requirements, a QVL was not established
at that time. Firms who provided information as a result of the
previous notice do not need to reapply and will have their previous
submittal returned to them to update as required, in accordance with
the revised evaluation criteria that will be provided. (0023) Loren Data Corp. http://www.ld.com (SYN# 0095 19980127\Y-0003.SOL)
Y - Construction of Structures and Facilities Index Page
|
|