COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 2,1998 PSA#2023U. S. Army Engineer District, Savannah, P.O. Box 889, Savannah, Georgia
31402-0889 C -- HEAVY DROP RIGGING FACILITY -- FORT BRAGG, NC SOL
DACA21-98-R-0025 POC Diego A. Martinez -- 912/652-5738 (Technical
Questions), Leila Hollis -- 912/652-5105 (Contractual Questions) WEB:
Corps of Engineers, Savannah District, Contracting,
http://www.sas.usace.army.mil. E-MAIL: Leila Hollis,
leila.hollis@sas02.usace.army.mil. 1. CONTRACT INFORMATION: The
Savannah District, U.S. Army Corps of Engineers requires the services
of an Architect-Engineer firm to prepare plans, specifications, design
analysis, and cost estimates for the design of a 120,210 sq. ft. Heavy
Drop Rigging Facility. The A-E will be required to provide concept
design, final design, services during construction and shop drawing
review services. This will be a firm fixed price contract. The contract
is anticipated to be awarded in May 1998 completed in August 1999. The
estimated construction cost range is $20,000,000 to $30,000,000. This
announcement is open to all firms regardless of size. Large Business
offerors must identify subcontracting opportunities with small
business, and small disadvantaged business on SF 255. If selected the
large business offeror will be required to submit a small/small
disadvantaged & women owned subcontracting plan in accordance with FAR
52-219.9 and DFARS 219.704/705 as a part of the Request for Proposal
package. The following subcontracting goals are the minimum acceptable
goals to be included in the subcontracting plan. OF THE SUBCONTRACTED
WORK, 62% TO SMALL BUSINESS: 10% TO SMALL DISADVANTAGED BUSINESS (A
COMPOSITE OF SMALL BUSINESS); 5% TO WOMEN-OWNED BUSINESS (A COMPOSITE
OF SMALL BUSINESS). Large business firms that intend to do any
subcontracting must convey their intent to meet the minimum
subcontracting goals on the SF 255, Block 6. Written justification must
be provided if the minimum goals cannot be provided. For additional
information please contact Ms. Leila Hollis, Contract Specialist, at
912/652-5105. **** 2. PROJECT INFORMATION: The selected firm will be
required to perform the following services: prepare the plans,
specifications, design analysis, and cost estimates for the design of
a 120,210 sq. ft. Heavy Drop Rigging Facility. The project includes ten
rigging lanes with recessed rollers, five 35-ton and four 25-ton
overhead cranes; administrative offices; control center; supply and
storage areas; interior docks with hydraulic lifts; container delivery
system; covered fuel/defuel point with pumps and two 500 gal tanks;
computerized pallet/platform tracking system and concrete hardstand.
Installation of an Intrusion Detection System (IDS) is required.
Supporting facilities include utilities; electric service; fire
protection and alarm systems; paving, walks, curbs and gutters; storm
drainage; information systems; HVAC; site improvements to include
precast concrete and steel vehicular bridge; and demolition. A
Comprehensive Interior Design package is required. Architect-Engineer
services during construction (shop drawing review and field visits) may
be required. For the deliverables at each stage of design we will
require the design drawing files in Integraph DGN format and CAL format
plus plotted hard copies. The AE will also need to create Source View
index for the files. **** 3. SELECTION CRITERIA: See Note 24 for
general A-E selection process. The selection criteria are listed below
in descending order of importance (first by major criteria and then by
each sub-criterion). CRITERIA A-F are primary. Criteria G thru I are
secondary and will only be used as "tie-breakers" among technically
equal firms. *** A. Specialized Experience and technical competence in
(1) Design of Rigging Facilities, (2) Industrial Warehouses (Container
Delivery System, Overhead Crane System & Computerized Pallet/Platform
Tracking System), (3) Design of Hydraulic Lifts, Recessed Roller System
& Capacity Scales. (4) Security Systems (Intruder & Smoke Detection).
(5) Use of CADD and translation into Intergraph DGN format and CAL
format. This should be shown in Block 8 & 10 of SF 255. (6) Use of
MCACES cost estimating *** B. Past performance on DoD and other
contracts with respect to cost control, quality of work and compliance
with performance schedules. *** C. Capacity to accomplish the work in
the stated contract period and to provide the following disciplines:
architectural, structural, civil, electrical engineering, mechanical
engineering, topo survey crew, industrial hygienist (asbestos),
interior designer, cost estimator and a fire protection engineer.
Please disregard the "to be utilized" statement at Block 4 of SF 255
and show the total strength of each discipline. *** D. Professional
Qualifications of key management and professional staff members. The
design team must include a Registered Fire Protection Engineer whose
principle duties are fire protection engineering or a Registered
Architect or Registered Engineer who is a full member in good standing
of the Society of Fire Protection Engineers (SFPE). *** E. Knowledge
of locality as it pertains in design and construction methods of
projects in the geographic area of this contract. **** F. Demonstrated
success in prescribing the use of recovered materials and achieving
waste reduction and energy efficiency in facility design. *** SECONDARY
CRITERIA. *** G. Extent of participation of Small Business (SB)
including (Women Owned Small Business (WOSB)), Small Disadvantaged
Business (SDB), historically black colleges and universities, and
minority institutions in the proposed team, measured as a percentage of
the total estimated effort. *** H. Proximity to the project site. ***
I. Volume of DoD contract awards in the last 12 months as described in
Note 24. **** 4. SUBMISSION REQUIREMENTS: See Note 24 for general
submission requirements. Interested firms must submit ONE (1) copy of
SF 255 (11/92 edition) for prime and ONE (1) copy of SF 254 (11/92) for
prime and all consultants to the following address: US Army Engineer
District, Savannah, ATTN: CESAS-EN-EA (Ms. Smulevitz), 100 W.
Oglethorpe, Savannah, GA 31401-3640, not later than close of business
the 30th day after the date of this announcement. If the 30th day is a
Saturday, Sunday, or Holiday, the deadline is the close of business of
the next business day. NO FAXED SUBMITTALS WILL BE ACCEPTED. FIRMS MUST
INCLUDE PRIME's ACASS NUMBER in BLOCK 3 of SF 255. For ACASS
INFORMATION: call 503/808-4591. No faxed submittals will be accepted.
Cover letters and extraneous materials (Brochures, etc.) are not
desired and will not be considered. PHONE CALLS are DISCOURAGED unless
ABSOLUTELY necessary. PERSONAL VISITS for the purpose of discussing
this announcement WILL NOT BE SCHEDULED. This is NOT a REQUEST for a
PROPOSAL. (0029) Loren Data Corp. http://www.ld.com (SYN# 0021 19980202\C-0009.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|