COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 20,1998 PSA#2036Contracting Division, Bldg 1116, Camp Lejeune NC 28547 41 -- CHILLERS SOL M6700198Q0011 DUE 030698 POC Point of Contact:
Contract Specialist, Martha Banks, 910 451 3011 E-MAIL: USMC
Contracting Division, Camp Lejeune NC, smtp[banksm@clb.usmc.mil].
CHILLERS 100 TON, 2 each. Complete Reciprocating Package Chillers, Air
Cooled, to produce a minimun of 99.3 tons @ 95 degree Ambient temp, 60
hz, 460 volts, 3 PH Required. Each system to consist of hermatic
reciprocating compressors, condenser section, complete control system
and all components necessary for safe and controlled unit operation.
Performance shall be in accordance with ARI Standard 590. Coils shall
be protected with wire grills or louvers. Coils shall be seamless
copper tubes mechanically bonded into rippled plate type fins.. A
subcooling coil shall be an integral part of the main condenser coil.
The refrigerant circuit shall include (2) two liquid line shutoff
valves, refrigerant filter drier, sight glass with moisture indicator
liquid line selenoid valve, thermal expansion valve, and insulated
suction line. Units shall have a centrally located control panel,
weatherproof, with all necessary components to operate system. Chiller
shall be compable for stable operation to a minimun of 30% of full
load without hot gas bypass. Delivery to be 60 days after receipt of
award. FOB Destination delivery to Marine Corps Base, Camp Lejeune, NC
28547. Awards will be based on price and best value. This is a
combined synopsis/solicitation for commercial items prepared in
accordance with the format in subpart 12.6. This announcement is issued
as a request for quotations and constitutes the only solicitation;
quotations are being requested. The following Federal Acquisition
Regulation FAR 52. 212-1, 52.212-3, 52.212-4, 52.219-6, DFARS
252-212-7000, DFAR 252.212-7001, DFARS 252.225-7001, and DFARS
252.225-7000 . The offeror is required to provide their Contractor's
DUNS code and commercial and Government entity (CAGE) code with their
offer. The CAGE code entered must be for that name and street address
provided by the Contractor. Offerors responding to this announcement
shall submit their offers in accordance with 52.212-1 and shall include
completed copies of provisions 52.212-3 and 252.212-7000. Submit name,
addresses and telephone numbers of Three (3) concerns with whom you
have done business, also submit descriptive literature for the item on
which you are quoting. All responsible sources may submit an offer
which will be considered. See Note 1 . (0049) Loren Data Corp. http://www.ld.com (SYN# 0221 19980220\41-0003.SOL)
41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page
|
|