COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 20,1998 PSA#2036Supply Department Indian Head Division, Naval Surface Warfare Center,
101 Strauss Ave, Indian Head, MD 20640-5035 43 -- DEALKALYZER SYSTEM SOL N00174-98-Q-0145 DUE 031398 POC Stanley
N. Rye, Jr., Code 1141Q, 301-743-6273 E-MAIL: Click here to contact the
contracting officer via e-mail., StanRyeJr@mail.ih.navy.mil. Item Name
-- Dealkalyzer System Quantity -- Two Vessels Construction -- Tank
Diameter -- 42" -- Design Flow -- 50 GPM @ 7.7 GPM/FT2 Normal --
Straight Side -- 6 FT (72 IN) -- Design -- 100 PSIG ASME Code --
Temperature -- Ambient -- Construction -- Structural Steel Support Legs
and Lifting Lugs -- Manhole -- 14 IN x 18 IN -- Handhole -- One 3 IN
Media Removal Connection Unit Internals -- Interior Lining -- Unlined
-- Underdrain -- Schedule 80 PVC -- Inlet Distributor -- Schedule 80
PVC -- Rgenerant Distributor -- Schedule 80 PVC -- Media -- 36 CU FT EA
Strong Base Anion Resin -- Capacity -- 273 KGR -- Effluent Quality --
5% -- 10% of Influent Alkalinity Instrumentation -- Flowmeters -- One
Influent Flow Indicator with Totalizer for each vessel Unit Externals
-- Automatic Control Valves -- Hydraulically Operated Diaphragm Valves
-- Cast Iron Body -- Buna N Diaphragm and Seals -- Valves are "Y"
Pattern Normally Open with Adjustable Open Stops on the Backwash Outlet
and Rinse Outlet Valves -- 2 IN Service Inlet & Outlet -- 3/4 IN
Backwash Inlet -- 3/4 IN Backwash Outlet -- 1-1/2 IN Rinse Outlet --
1-1/2 IN Brine Inlet -- Gauges -- 2-1/2 IN Dial Service Inlet & Outlet
Pressure Gauges -- Piping -- Schedule 40 Carbon Steel with 125 LB Cast
Iron Fittings -- Coatings -- Red Oxide Primer, 1-2 MILS DFT on Vessel
Exterior -- Regeneration System -- One Brine Tank, Unit Piping,
Pressure Gauge, Level Control Valve, Rate Set Valves and eductor(to be
installed by others) Skid Mounted Assembly -- The two dealkalyzers
with face piping and valve nests will be mounted on a single skid with
one PLC based controller, properly wired and tubed with polyethylene
tubing. Semi-Automatic Operation -- A PLC and Aquamatic stagers are
suppklied to sequence the regeneration steps. A light for "regeneration
required and a push button to start regeneration are provided with with
units automatically returning to service after regeneration is
complete. A contact for customer's horn is also provided. An electrical
interlock to prevent more than one unit regenerating at a time is
included. Includes -- Engineering Drawings and Instruction Manuals --
One Day of Start-up Supervision and Operator Training by a Qualified
Service Engineer. (0049) Loren Data Corp. http://www.ld.com (SYN# 0222 19980220\43-0001.SOL)