COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 24,1998 PSA#2038Regional Contracting Department (Code 201), Fleet and Industrial Supply
Center, Box 300, Pearl Harbor, HI 96860-5300 38 -- DUST COLLECTOR SOL N00604-98-Q-A610 DUE 022698 POC Joeanne
Fletcher-Myles, (808) 474-2397, Ext. 106, Purchasing Agent, Marguerite
Mattson, Contracting Officer. DUST COLLECTOR (AMENDMENT) SOL
N00604-98-Q-A610 DUE 022698. Correction: This action originally
publicized in the CBD dated 2/11/98 was corrected on amendment dated
2/12/98 is hereby corrected as follows: The date set for closing is
hereby extended to 26 Feb 98. The following questions have been posed:
1.How are they going to pick up the collector and fan assembly? 2. Is
a common base required for the collector and fan assembly? 3. Why a
spark proof fan, it is on the clean side of the collector. 4. Item 6)
subparagraph(a) states: be equipped with filter cartridge and element
meeting the following requirements: a) certified by and independent
test laboratory, to a cleaning/filtering efficieny of at least 99.999%
micron particulate. What is the micron particulate size? 5.
Sub-Heading: DC shall...items(14) by the term "have overall
construction housing of at least 7 gage ASTM...Do you mean the
filtering housing (also known as the tube sheet) only? 6. Sub-heading
"DC shall...item (1) "to simplify shipment"—can the support leg
structure and hoppers be supplied loose? ANSWERS ARE AS FOLLOWS: A. The
dust collector and fan assembly shall be picked up by the lugs/lifting
eyes that are being provided in the contract. B. a "common" base is
not required for the dust collector and fan assembly. However, if the
DC is provided in multiple sections, each section must have its own
frame to support it off the ground along with their own lugs/lifting
eyes, nameplate, weight certification, etc. C. A spark resistance fan
is requested in case the filter element/housing internals fails during
operation, nothing is to prevent the steel grit from hitting the fan,
thereby, causing a spark. D. See 2A BELOW. E. Yes, only the filtering
housing is requested to be of at least 7 gage ASTM hot rolled steel.
This does not include any internal/external structural housing
framework/supports. F. No. DC shall be fully assembled and tested prior
to delivery to Pearl Harbor Naval Shipyard. 2. The following was
Omitted when sent to the CBD. A. Add "70" after the first word "NFPA on
page 2 of 6. B. Add "efficient on 0.8 "after"DC shall...6)a).. of at
least 99.999%". C. add "4" after "DC shall...13)...Seismic zone". D.
Change "in para 3.7" under "DC shall..16).."to read noise level
specified under environmental conditions 2)" E. Change "in para 3.7"
under "fan Shall..6).."to read noise level specified under
environmental conditions 1)" 3. Request evaluation factors also include
"evaluation of past performance. All other information publicized in
the original synopsis remains unchanged. (0051) Loren Data Corp. http://www.ld.com (SYN# 0195 19980224\38-0001.SOL)
38 - Construction, Mining, Excavating and Highway Maintenance Equip. Index Page
|
|