COMMERCE BUSINESS DAILY ISSUE OF MARCH 13,1998 PSA#2051Department of the Army, Headquarters, Military Traffic Management
Office, ATTN: MTTM-T Room 629, 5611 Columbia Pike, Falls Church, VA
22041-5050 81 -- PURCHASE OF CARGO-WORTHY ISO CONTAINERS SOL DAMT01-98-Q-98-056
DUE 031198 POC Sarah Wiley (703) 681-9770 WEB:
http://wileys@baileys-emh5.army.mil,
http://wileys@baileys-emh5.army.mil. E-MAIL:
wileys@baileys-emh5.army.mil, wileys@baileys-emh5.army.mil. The
Government requires the purchase of various types of ISO Cargo
containers and container related equipment as described below. Subject
containers must be delivered as specified in the description provided.
If the RDD provided below can not be met, please provide your earliest
availability for delivery any units that are offered in response to
this request for quotes. NOTE: THIS REQUIREMENT IS SET ASIDE
EXCLUSIVELY FOR PARTICIPATION BY SMALL BUSINESSES. THE SMALL BUSINESS
SIZE STANDARD IS 500 EMPLOYEES FOR SIC 3441. Please provide unit price,
drayage and all other related costs below as applicable. All containers
purchased by the Government must have not less than (NLT) one set of
fork lift pockets. In the case of 40' ISO containers, those not having
forklift pockets may be offered if there exists no availability of 40'
containers having forklift pockets. Such offered units shall be
identified by placing an asterick (*) next to the appropriate CLIN
identified in your proposal. Container(s) offered to the Government
must be in cargo worthy/sea worthy condition. Container(s) must have
current CSC inspection and be wind and water tight. Cargo/sea worthy
condition inspection incorporates the following: 1. ISO -- No
alteration of K-1,K-2, dimensions. 2. WELDS -- No cracked welds on the
welds of prime structural components. 3. PANELS -- Dents, bonds and
bows up to 50mm into the cube. 4. CORNER POSTS -- Dents to 25mm. 5. TOP
SEARAILS -- Dents to 25mm. 6. HEADERS -- Front 25mm, Rear 35mm. 7.
BOTTOM RAILS -- Dents up to 50mm (no limit on flanges). Flange comes up
to webs, except on bottom side rails. 8. FLP SIDES, CROSSMEMBERS
TUNNELS RAILS AND BOLSTERS -- Debris up to 75mm (no limit on flanges)
horizontal cuts in webs to 400mm. Flange cuts up to welds. 9. DOORS --
Operable, light & watertight and sealable. 10. FLOOR GOUGES -- Up to
15mm deep and 150mm wide, 5mm deep over 150mm wide, uneven adjacent
boards/threshold plate up to 5mm. 11. FLOOR SEPARATION -- Up to 10mm at
fastener. 12. RAIN GUTTERS & J BARS -- No interfering with the door.
13. VENTS -- Functioning and watertight or closed off. 14. MARKINGS --
All serial numbers and IS required markings must be legible. TIR and
CSC plates must be present. 15. GENERAL -- No missing door hardware. No
holes into the cube. No cuts except as noted above. No corrosion that
will not pass a hammer test. No hazardous cargo residues or foul odors.
Containers are to be delivered FOB Destination. 98-056 Details are
provided as follows: 9x20' ISO Dry Containers delivered to: (nine
units) McAbee Construction, Inc. 5724 21st Street Tuscaloosa, AL 35403
POC: Harold Parker (205) 349-2212 Required Delivery Date: 18 March
1998 Truckers are required to call 24 hours prior to arrange for
delivery. Acceptance inspection required. (The Government intends to
inspect equipment at the depot of origin. Facility hours of operation
are 0800 -- 1600. Price Proposal: Qty Unit Price Extended Price CLIN
0001 ___ EA $__ __ __ __ $__ __ __ ___ 20' ISO Container(s) CLIN 0002
___ EA $__ __ __ __ $__ __ __ ___ Delivery Depot of origin of units
offered under this proposal. Name:__ __ __ __ __ ___ Street:__ __ __ __
__ ___ City/State/Zip:__ __ __ __ ___ __ __ ____ __ __ __ __ __ __ __
__ __ __ __ __ __ __ ___ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __
__ __ __ ___ Please submit your offer to Sarah Wiley by facsimile NLT
12:00 on 12 March 1998 @ (703) 681-5621 or 9112, or e-mail
(wileys@baileys-emh5.army.mil. (0070) Loren Data Corp. http://www.ld.com (SYN# 0360 19980313\81-0003.SOL)
81 - Containers, Packaging and Packing Supplies Index Page
|
|