COMMERCE BUSINESS DAILY ISSUE OF MARCH 20,1998 PSA#2056Integrated Support Command, 4640 Urquhart Street, New Orleans, LA
70117-4698 43 -- AIR COMPRESSORS SOL DTCG29-98-Q-8CC095 DUE 042098 POC SK1
Charles Dixon/Contracting Officer (504) 942-4080. Provide labor,
material & supervision to complete the following: Provide and install
new air compressor system. Compressor system must provide a working
pressure of 125 PSI @ 400CFM and a minimum of 100HP. Remove and dispose
of existing main & standby compressors and filter dryer. Install 2 new
electric driven rotary type compressor systems capable of meeting the
above delivery requirements under peek dual operation. The system
shall be fully automated in its sensing and starting capabilities. The
system shall be rated to a high end temperature of 115 degrees
fahrenheit ambient operation and the units shall be enclosed to reduce
noise and provide inlet and outlet air. The air dryer shall be rated
at no less than 175 PSI and an inlet flow of no less than 400 cfm with
automatic condensate drain. Installation is at Commander, USCG Air
Station, 8930 Ocean Drive, Corpus Christi, TX 78419-5220. (0077) Loren Data Corp. http://www.ld.com (SYN# 0225 19980320\43-0004.SOL)
43 - Pumps and Compressors Index Page
|
|