COMMERCE BUSINESS DAILY ISSUE OF MARCH 20,1998 PSA#2056Department Of Veterans Affairs Medical Center, 4646 John R, Detroit, MI
48201 J -- CERTIFICATION AND REPAIR OF LANDIS & STENNIS HOODS AND SAFETY
CABINETS SOL RFQ:553-12-98 DUE 041398 POC Barbara A. Lupo, 313-576-3737
Provide to the Department of Veterans Affairs, John D. Dingell Medical
Center, Detroit, Michigan repair of hoods and safety cabinets. The
VAMC Detroit requires that the vendor certifying and repairing fume,
perchloric acid, nuclear and medicine/nuclear iotope hoods and biologic
safety cabinets, be trained in the proper and safe use of the Landis
and Stennis (formerly Landis & Gyr). Insight energy management and HVAC
systems of controls and ahas been certified for use of this sytem,
including possession of all proprietary software from the manufacturer
(Lanis & Stennis) necessary for operating this system and balancing
air flows. This is in addition to the firma (and each of its assigned
personnel) possesing appropriate hood/biologic safety cabinet
manufactuer's certification and other training necessary for proper
testing, balancing and repair of the VAMC's hhods and biologic safety
cabinets. All work must be performed by individuals with documented
manufacturer's training for the indicated equipment, Involved
manufacturers include Baker, Nuaire, Forma, Hamilton, and Labconco.
Proof of training must be documented and included in the quote package.
All parts used for servicing the indicated equipment will be approved
by the appropriate vendor of the hood in question as suitable for use
with this equipment. Because of the integrated assembly itself and
quotes must be for comprehensive service for all system components,
including interfaces to the VAMC's energy management system and it's
controls. Quotes for service for less than all equipment items or for
less than all protions of the systme will not be acceptable. Quotes
will not be entertained from vendors who (1) Do not have ready access
to parts from the appropriate fume hood or biologic safety cabinet hood
manufacturer(s), (2) Do not have the requisite training and
certification from these manufacturers, (3) Who do not have
certification from an approved school or course for hazardous and
biologic cabinet certification or (4) Do not have certified training
and access to parts from Landis and Stennis for their Insight system of
HVAC controls. Numbered note #23 applies. All qualified vendors may
request a quote package in writing address to the contracting officer.
Please include company name, address, telephone number, contact person
and fax number. Request may be faxed to the contracting officer at
313-576-1990. (0077) Loren Data Corp. http://www.ld.com (SYN# 0054 19980320\J-0007.SOL)