COMMERCE BUSINESS DAILY ISSUE OF MARCH 25,1998 PSA#2059Department of Veterans Affairs, VA Medical Center (529), ATTN:
Contracting Officer (90C), 325 New Castle Road, Butler, PA 16001-2480 C -- REPLACE MAIN STEAM LINE SOL RFP 529-12-98 DUE 040798 POC Terrence
L. Blair, 724/477-5052 A/E services to furnish fully developed
construction documents, including preliminary plans, technical
specifications, working drawings, cost estimates, and construction
period services for Project #98-120, Replace Main Steam Line, VA
Medical Center, Butler, PA. The project, including working drawings,
specifications, and construction period services will be designed
completely with provisions for phasing the construction portion into
multiple phases in order to accomplish the work based on the
availability of funds. This work includes, but not limited to:
mechanical and site modifications for replacement of main steam line.
The project scope will include, but limited to: the replacement of
approximately 3,500 feet each of 8" high pressure steam line, 1-1/2"
high pressure condensate, and 4" low pressure condensate return lines.
Additionally, replace 9 precast concrete manholes. The existing lines
are a pre-engineered system with fiberglass insulation. Existing
system was installed in 1993 and the insulation has failed and the
manholes are leaking ground water. The existing system shall be
evaluated by the A/E who shall make recommendations to their disposal.
Completion time for A/E design is 90 calendar days. The estimated
construction range is $500,000.00 to $1,000,000.00. Only firms with
prior experience in the design of similar type projects, and those with
the professional capacity to complete this type of work will be
considered. . The following are the evaluation factors in order of
importance for this project: TEAM PROPOSED FOR THIS PROJECT: Specific
experience/qualifications of personnel proposed and technical
competence of the firm with similar projects; PREVIOUS EXPERIENCE OF
PROPOSED TEAM; Project experience on government contracts and previous
experience with similar projects; PROPOSED MANAGEMENT PLAN:
Professional capacity to perform within time limitations and plan for
design and construction services; LOCATION AND FACILITIES OF WORKING
OFFICES: Prime firm and consultants; PROPOSED DESIGN APPROACH FOR THIS
PROJECT: Proposed design philosophy, proposed energy efficiency/waste
reduction, and anticipated problems and potential solutions;
ESTIMATING EFFECTIVENESS: Ten most recently bid projects and compare
actual construction cost; MISCELLANEOUS EXPERIENCE AND CAPABILITIES:
Interior design, CADD and other computer applications, value
engineering and life cycle cost analyses, environmental and historic
preservation considerations, and CPM and fast track construction;
AWARDS: Awards received for design excellence; and LITIGATION:
Litigation involvement over the last 5 years and its outcome The
geographical area of consideration is a 100 mile radius of the VAMC,
Butler, PA. This is not a request for proposal. Those firms which meet
the requirements are invited to submit two copies of Standard Forms
254 and 255 no later than 4/7/98, 4:30 P.M.. SIC Code is 8712. Award is
subject to availability of funds. See Numbered Note 24. (0079) Loren Data Corp. http://www.ld.com (SYN# 0019 19980325\C-0001.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|