Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 3,1998 PSA#2066

SSPORTS Environmental Det, Code 110RH, PO Box 2135, Vallejo, CA 94592-0135

46 -- OIL WATER SEPARATOR SYSTEMS SOL N62678-98-Q-1057 DUE 041698 POC Roger Helbig, Contracting Officer, (707) 562-3484, fax (707) 562-3275 WEB: none, none. E-MAIL: Roger Helbig, Contracting Officer SSPORTS Environmental Det., helbigr@psns.navy.mil. Seven (7) each oil water separators to treat flows of rinsate consisting of tapwater, and typical non-emulsified oils, greases and small amounts of sediment from vehicle and equipment washing facilities, and storm water runoff from the paved areas of these facilities. Design parameters include: Inlet flow rate: 100gpm. Influent temperature: 40-150 oF. Specific gravity range of petroleum products to betreated/separated: 0.68-0.95. Performance: Maximum influent TPH: 1900mg/l; Maximum TPH discharge in water effluent: 10mg/l. Physical dimensions: inlet/outlet flange size :6" dia, 150#, sch 40 FF, bolted flanges. Overall length: less than 12.0ft. Nominal separator diameter: 4.5ft or less. Nominal 1000 gal capacity, minimum 400 gal oil spill/storage capacity. Other Features: Hinged manway access covers to oil and sludge chamber to be a minimum of 24" ID, with extensions to position top of access cover 4" to 6" above the ground surface, based on inverts of inlet and outlet piping below ground surface (bgs), dimensions in inches, as follows: Separator 1: Inlet 58" bgs, Outlet 64"bgs; Separator 2 : Inlet 47"bgs, Outlet 53"bgs; Separator 3 : Inlet 18"bgs, Outlet 23"bgs; Separator 4 : Inlet 50"bgs, Outlet 56"bgs; Separators 5 & 6 : Inlet 38" bgs, Outlet 38" bgs; Separator 7 :Inlet 29" bgs, Outlet 34"bgs. Each separator shall have an oil level sensor alarm with NEMA IV enclosures, be of double wall construction with a between wall, interstitial leak detection sensor, be designed for underground installation. have an external anticorrosion coating/cathodic protection unless the vendor uses an external separator structure of fiberglass or other material that is not subject to corrosion, have 2" IPS vent lines to atmosphere for each internal chamber where gases or vapors could accumulate. have a 4" IPS oil pump out line with extension to within 4" to 6" of the ground surface, have a manufacturers identification plate with model number, date of manufacture, nominal capacity, and other customary information, The identification plate shall be fabricated from a durable material and stamped, engraved or embossed with the required information, and shall be resistant to degradation from corrosion, and weathering, and shall be attached to the exterior of the separator or component part at a location which will be clearly visible after installation without the need to excavate or enter the separator. Documentation traceable to and describing the manufacturer's warranties for materials and fabrication shall be furnished. A copy of the manufacturer's installation/operation/manual for the model offered shall be provided. Each separator shall be furnished with a reinforced concrete hold down pad with attachment hardware and a minimum of two hold down straps sufficient for securing the unit and resisting the buoyant effect of groundwater. Further details of the hold down pad and straps, follow. The hold down pad and strap design shall assume a ground water level of two feet below the surface of the ground, the hold down strap attachment hardware shall be of sufficient strength to be used for attaching lifting hardware to be used during installation and positioning of the pad in the excavation, and the pad design shall be examined and approved by a registered professional engineer having the required knowledge and experience in the design of this component and its intended use. The manual or separately furnished documentation shall provide sufficient information to support ordering of any component part(s) of the unit that may require periodic replacement including seals, instrumentation, etc. that may be subject to wear or degradation in service. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The request for quotation number is N62678-98-Q-1057. Solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-04 and Defense Acquisition Circular 91-13. The Standard Industrial Classification Code for this procurement is 3589, 500 employees. The award will be a firm fixed price purchase order and will be awarded using Simplified Acquisition Procedures. Quotations are being solicited on a full and open competition basis. Shipping terms will be FOB destination Travis AFB, Fairfield, California 94533. FAR Clauses/Provisions 52.203-3 Gratuities, 52.212-1 Instructions to Offerors -- Commercial Items, 52.212-3, Offeror Representations and Certifications -- Commercial items. 52.212-4 Contract Terms and Conditions -- Commercial Items, 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items (incorporating FAR 52.222-35 Affirmative Action for Special Disabled and Vietnam Era Veterans, 52.222-36 Affirmative Action for Handicapped Workers, 52.222-37 Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era, 52.225-3 Buy American Act-Supplies, 52.225-21 Buy American Act-North American Free Trade Agreement Implementation Act-Balance of Payments Program, -- Commercial) Items apply to this acquisition. Offerors responding to this announcement must provide the information contained in 52.212-1, Instruction to Offerors -- Commercial items and must include a completed copy of provision 52.212-3, Offeror Representations and Certifications -- Commercial items. Note, that full descriptive manufacturer's literature and an itemized quotation showing each separately priced system component are required in order to properly evaluate quotations for award. The Contractor shall extend to the Government the full coverage of any standard commercial warranty normally offered in a similar sale, provided such warranty is available at no additional cost to the government. The offeror should also provide its Commercial and Government Entity (CAGE) code, Contractor Establishment code (DUNS Number) and Tax Identification Number. If a change occurs in this requirement, only those offerors that respond to this announcement within the required time frame will be provided any changes/ amendments and considered for future discussions and/or award. The written quotes and the above required information must be received at this office on or before 16 April,1998 at 4:00 PM Pacific time. Submit quotations to SSPORTS Environmental Detachment. Code 110RH Bldg 229, PO Box 2135, Vallejo, CA 94592-0135. Facsimile quotes are acceptable (707-562-3275). All responsible sources may submit an offer which will be considered by the agency. (0091)

Loren Data Corp. http://www.ld.com (SYN# 0223 19980403\46-0001.SOL)


46 - Water Purification and Sewage Treatment Equipment Index Page