COMMERCE BUSINESS DAILY ISSUE OF APRIL 8,1998 PSA#2069Department of Veterans Affairs, VA Puget Sound Health Care System
(663/90C), 1660 S. Columbian Way, Seattle, WA 98108 Z -- FIRE SPRINKLER SYSTEM BUILDING 6 & 85 SOL 663-33-98 DUE 052998
POC Bill Thompson (253) 589-6095 The American Lake Division of the
Puget Sound Health Care System requires the services of a mechanical
contractor to provide all labor, materials, tools, equipment, and
supervision for the supply and installation of a fire sprinkler system
in Building 6 (domiciliary) and Building 85 (various health care
offices) at the American Lake Division Medical Center, 9600 Veterans
Way, Tacoma, WA 98493. The new fire sprinkler systems will be in full
compliance with NFPA 13 requirements. The fire sprinkler system
contractor must be certified in accordance with ASME guidelines for
both the development of shop drawings and the installation of the fire
sprinkler system. The contractor will be responsible for the
development of working drawings for the installation of all risers,
piping, sprinkler heads, tamper switches, and flow switches. The
Building 6 fire sprinkler system covers approximately 24,000 square
feet of interior space on two floors and attic plus a basement area.
The fire sprinkler system shall have 2 flow zones per floor. The
contractor will provide and install approximately 160 sprinkler heads.
In addition, the contractor will provide and install 7 tamper switches
and 7 flow switches and wire all switch devices to the existing fire
alarm panel in Bldg. 6. The existing dry system will remain. The
contract will require the installation of 3 tamper switches to be
installed on the existing dry system. The Building 85 fire sprinkler
system covers approximately 35,000 square feet of interior space on
three floors and attic plus a basement area. The fire sprinkler system
shall have 2 flow zones per floor. The contractor will provide and
install approximately 370 sprinkler heads. In addition, the contractor
will provide and install 9 tamper switches and 9 flow switches and
wire all switch devices to the existing fire alarm panel in Bldg. 85.
The existing dry system will remain. The contract will require the
installation of 3 tamper switches to be installed on the existing dry
system. The contractor will be responsible for all testing and will
submit to the VA documentation of the system's compliance with
applicable NFPA standards. There will be a site inspection on May 14,
1998 at 10AM in Building 17 at the American Lake Division. Completion
time will be 180 calendar days following Notice to Proceed. Estimated
cost range will be from $250,000 to $500,000. The VA anticipates
awarding a firm, fixed contract. Standard Industrial Code is 1711. This
solicitation is not set aside for small business in accordance with the
Small Business Administration Special Demonstration Program.
Construction trades involved are primarily mechanical and electrical.
The solicitation package will be available on or about April 28, 1998.
Interested parties are to submit written solicitation requests to:
Contract Officer (90); VA Medical Center; Puget Sound Health Care
System; American Lake Division; Tacoma, WA 98493. FAX requests will not
be accepted. Bid opening will be May 28, 1998 at 2PM PST in Building
17, Room 110 at the American Lake Division. (0093) Loren Data Corp. http://www.ld.com (SYN# 0111 19980408\Z-0004.SOL)