|
COMMERCE BUSINESS DAILY ISSUE OF MAY 5,1998 PSA#2088U.S. Army CECOM, CECOM Acquisition Center, Fort Monmouth, NJ
07703-5008 59 -- AN/TTC-56(V)1 SINGLE SHELTER SWITCH DUE 060598 POC Jon Vogel
732-532-1486 E-MAIL: Program Manager, vogelj@doim6.monmouth.army.mil.
This office is attempting to identify vendors of capable of providing
the various existing switching equipments delineated below, integrating
them into a downsized shelter configuration (designated AN/TTC-56 (V)1
Single Shelter Switch), and providing the associated technical
services required to deliver, train and install the equipment at their
final field destinations. The U.S. Army Office of the Project Manager,
Warfighter Information Network-Terrestrial, is seeking sources capable
of integrating, shelterizing, testing, and delivering existing,
certified interoperable Tactical Switching Equipment. To PM WIN-T's
knowledge, the only existing switches/equipment that meet these
requirements are specifically, any of GTE Corporation's family of
Compact Digital Switches (CDS), GTE PN: 02-1414102-1, and Switch
Multiplexer Units (SMU), GTE PN:02-275-4030-3, GTE's Single Row Nest
(SRN), GTE PN: 03-2753097-1, the Army family of Line Termination Units
(LTU) CV-4180A(V)1, CV-4180a(V)2, and CV-4180A(V)3, PNs:
SM-E-8192940-2, SM-D-823020-4, and SM-D-823020-5, and all associated
peripherals, cables, and variable card sets associated with these
equipments. The switching equipment must be able to run the Routing TEP
switch software developed by and partly owned by GTE. Additionally, any
proposed alternative to the above listed equipment must be form, fit
and function equivalent. The SSS must conform to the technical
requirements of specification A3252533. The aforementioned Tactical
Switching Equipments provide existing, forward looking, tactical
switching systems which have already been certified by the Executive
Agent for Tactical Switches. As the Government does not own the full
technical documentation and data rights to the aforementioned
equipments, potential qualified vendors must obtain/possess the
technical information and data rights to the GTE CDS and SMU family of
switches, and the Digital Line Termination CCAs necessary to populate
the switches and LTU to meet various terminal interface requirements
of all potential military users. Potential qualified vendors must also
possess and demonstrate an intimate knowledge of both MSE and
AN/TTC-39 family of circuit and message switches. Vendors must possess
and demonstrate the capability to provide technical engineering
support services necessary to field, train and support this equipment.
(0121) Loren Data Corp. http://www.ld.com (SYN# 0212 19980505\59-0009.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|