giffordf@ars.usda.gov. The USDA-ARS in Albany, Ca. has a requirement
for a FPLC system which can perform as follows: The system must perform
separations based on a variety of sample characteristics molecular
weight, net surface charge, hydrophobicity, while retaining biological
activity. It should have large open column 0.05-20mls/min flow rate,
two pump gradient system, control of up to nine motorized valves (one
automatic three position valve must be included) for control of column
selection, buffer selection, flow reversal and multi-dimensional
chromatography. The entire wetted flow path must be inert to halides.
The system must automatically and continuously record for the complete
run the flow rate, auto scaled UV signals, actual and programmed
conductivity of the eluent, eluent ph, and system pressure, accumulated
time of run, all valve positions and changes in position, activity of
fraction collector. Valves must be driven electronically, with no
external air pressure required. The column equilibration feed-back must
be monitored. The controller must allow programs to be time based,
volume based & column volume based. The system must be a two pump
gradient system, with dynamic mixing. A minimum 100 position fraction
collector controllable from the system software must be included.
Control of chart recorder, fraction collector, gradient mixer, air
sensors, and three pumps from the system software. Equipment must be
operational in a cold room at 4C. Post run chromatographic analysis by
software. Documentation of runs should be automatic and complete. The
data must be in a form for export to a spreadsheet. Column definable
pressure limit which stops pump & sets off an alarm. The equipment
listed below will meet our requirement but alternate source will
certainly be considered. Installation and training must be provided by
the vendor at no additional cost. The system quoted should include
spare parts likely to be needed in the first 12 months of operation. 01
Mono HR5/5 Column FPLC High Resolution Ion exchange Column SAX 5x50mm
02 Mono S HR5/5 Column 03 FPLC High resolution ion Exchange column SCX
5/50mm 04 Superdex 200 HR 10/30 05 Hitrap HIC Test kit 5x1ml 06 Phenyl
Superose HR 5/5 FPLC High resolution hydrophobic interaction column
5/50mm 07 SuperLoop 10ml 08 PH Electrode PH/C-900 09 Hiload Pump P-50
10 Motorized Valve PV-900 11 Cell 912 11 300 MHZ Computer and 17"
Monitor "Executive Order 12845 (4/21/93) requires that model(s)
supplied by the vendor must meet EPA Energy Star requirements for
energy efficiency." & *Year 2000 Compliant* 12 HP Inkjet printer 692C
w/cable Requests for proposals will be available after May 20, 1998 &
can be obtained by mailing, faxing or e-mailing your request to the
attention of Fred Gifford as listed in this notice. (0125) Loren Data Corp. http://www.ld.com (SYN# 0280 19980508\66-0001.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|