Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 1,1998 PSA#2106

Federal Correctional Institution, 27072 Ballston Road, PO Box 8000, Sheridan, OR 97378-8000

56 -- AMENDMENT 0001 TO WIDE FLANGE STEEL I-BEAM TRUSSES FOR WAREHOUSE ADDITION AT FEDERAL CORRECTIONAL INSTITUTION, SHERIDAN, OREGON SOL RFQ 230-0036-8 DUE 060498 POC Christina Berggren (Brown), Contract Specialist (503)843-4442 ext. 263, fax (503)843-7623, email cbrown@bop.gov E-MAIL: Christina Berggren (Brown), Contract Specialist, cbrown@bop.gov. Solicitation RFQ 230-0036-8, posted to the CBD on May 18, 1998, has been amended. Amendment 0001 is issued to the above combined synopsis/solicitation for wide flange steel I-beam trusses for warehouse addition at Federal Correctional Institution, Sheridan, Oregon. This amendment is issued in accordance with FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only amendment of the above solicitation, offers are being requested, and a written amendment will not be issued. This amendment is issued to furnish questions and answers concerning this synopsis/solicitation. QUESTIONS AND ANSWERS: Question No. 1: What is the imposed dead load on the steel beams from the steel Roof Panels, the 18ga Steel Decking, and the 3" Foil Cake Foam Insulation? Answer: Offerors to review drawings and provide engineered steel I-Beam trusses to meet all applicable Federal, Local and State codes and 1994 Uniform Building Codes, etc. Question No. 2: What are the live load, Ground Snow Load, Wind Speed, and Collateral Load requirements? Answer: See answer to Question No. 1. Question No. 3: Would design be done in accordance with the Uniform Building Code 1994 edition? Exposure B or C? Answer: See answer to Question No. 1. Exposure B is applicable. Question No. 4: Finish -- primed or galvanized? Answer: The finish is primed. Question No. 5: What is the size of the Steel I-beams? The A.I.S.C. Manual of Steel Construction lists three W18 sizes with 6" flanges: W18X35, W18X40 & W18X46. Answer: W18X35 is the section weight per foot. Question No. 6: What is the bolt pattern for anchor bolts? Answer: The bolt pattern for anchor bolts is 4" on center. Question No. 7: What is the size of the anchor bolts? Answer: The anchor bolts are 3/4" x 16 galvanized J-bolts. Question No. 8: Are shop drawings required for this project? engineering drawings? Answer: Shop drawings/engineering drawings are required. AMENDMENT ACKNOWLEDGMENT: Offers must acknowledge receipt of this amendment before the hour and date specified in the synopsis/solicitation. Failure of this acknowledgment to accompany the offer may result in rejection of your offer. If as a result of this amendment you desire to change an offer already submitted, such change may be made by letter. The letter must refer to the solicitation and this amendment, and be received before offers are due. The synopsis/solicitation RFQ 230-0036-8 is amended as indicated as above. The hour and date for receipt of offers has not changed. Except as provided herein, all other terms and conditions of RFQ 230-0036-8 remain unchanged and in full force and effect. End of Amendment 0001 to synopsis/solicitation RFQ 230-0036-8. (0147)

Loren Data Corp. http://www.ld.com (SYN# 0334 19980601\56-0005.SOL)


56 - Construction and Building Materials Index Page