(MD-33), Attn: ORDSC, Research Triangle Park, NC 27711 66 -- MULTIPARAMETER WATER QUALITY DATA SONDES AND CALIBRATION CABLE
(DRY USE ONLY) SOL MK0187 DUE 062498 POC Phyllis Roberts, Contracting
Officer, (919) 541-3564 or Barbara Stearrett, Team Leader, (919)
541-3113 E-MAIL: Click here to contact the Contracting Officer via,
roberts.phyllis@epamail.epa.gov. The U.S. Environmental Protection
Agency's (EPA), National Health and Environmental Effects Research
Laboratory/Western Ecology Division, Corvallis, Oregon, intends to
award a purchase order on a sole source basis to Endeco/YSI c/o Whitney
Equipment Company, 14636 NE 95th St., Redmond, WA 98052, for the
purchase of two (each) Multiparameter Water Quality Data Sondes and six
(each) of YSI Model 6920 Data Sondes, and one each 10 ft. calibration
cable (dry use only). This equipment will be used to analyze
environmental samples, primarily water samples from rivers, streams,
lakes and groundwater aquifers. Results of these analyses will be used
to create and interpret scientific information and will be published
in peer literature. The EPA believes Endeco/YSI c/o Whitney Equipment
Company is the only source capable of meeting our needs for the
following reasons: The equipment must be compatible with existing EPA
equipment. It is critical to EPA data interpretation that all
measurements are comparable because EPA will be comparing measurements
from different locations and attempting to understand ecological
processes based on these comparisons. Each data sonde requires
additional hardware, such as cables to communicate with the sonde for
calibrating and downloading data. Both the Model 6920 and Model 600 XLM
data sondes use the same peripheral equipment as the units already in
use by the EPA. Salient characteristics of the equipment are as
follows: Model 600XLM includes 2 inch or less external diameter, with
internal battery compartment, data logging and storage capabilities,
field-replaceable probes for temperature, conductivity, low
ionic-strength pH, and dissolved oxygen. Dissolved oxygen probe must
utilize rapid-pulse technology to eliminate the need for stirring.
Specific conductance and dissolved oxygen percent saturation are
available as calculated outputs. Includes bulkhead connector to attach
field cable. RS232 and SDI-12 communication capabilities, probe guard,
and transport and calibration cup. Model 6920 includes internal battery
compartment using size AA bateries, data logging and storage
capabilities, field-replaceable probes for temperature, conductivity,
low ionic-strength pH, turbidity, and dissolved oxygen. The dissolved
oxygen probe must utilize rapid-pulse technology to eliminate the need
for stirring. It is essential that the turbidity probe contain an
automatic wiper to prevent fouling during long-term deployments.
Specific conductance and dissolved oxygen percent saturation are
available as calculated outputs. The new data sondes will be used
together with the data sondes previously purchased for studies of
off-channel habitat on the Willamette River. The rapid-pulse system for
DO measurements provides very stable DO readings for long-term
unattended monitoring. All interested parties must respond within 15
days of the date of this announcement. Interested vendors shall: 1)
include information on the proposed equipment which clearly supports
the requirements outlined above and 2) provide itemized pricing that is
sufficient to make a determination that competition is feasible.
Response to this synopsis must be in writing. Submit response to the US
EPA, Attention: Phyllis Roberts (MD-33), Contracts Management Division,
Research Triangle Park, NC 27711. No telephone or faxed requests will
be honored. See Numbered Note(s) 22 and 26. (0160) Loren Data Corp. http://www.ld.com (SYN# 0343 19980611\66-0011.SOL)