|
COMMERCE BUSINESS DAILY ISSUE OF JUNE 11,1998 PSA#2114SOUTHWESTNAVFACENGCOM, 1220 Pacific Highway, San Diego, CA 92132-5187 C -- ARCHITECT AND ENGINEERING SERVICES SOL N68711-98-D-5053 DUE
071398 POC Thomas Christopher Pino, Contract Specialist (619) 532-3263,
Dorothy I. Lestage, Contracting Officer, (619) 532-1301 WEB: Southwest
Division, Naval Facilities Engineering Command,,
tcp@efdswest.navfac.navy.mil. The SOUTHWEST Division, Naval Facilities
Engineering Command, San Diego, CA is currently seeking services of
Architect/Engineer firms to perform engineering studies and designs for
corrosion prevention and cathodic protection, world wide. Services are
corrosion control and cathodic protection designs and studies for
various facilities, world wide. The Scope of Work may also include
preparation of Requests for Proposals(RFP's) for competitive bidding of
Design-Build Construction Contracts, corrosion control and cathodic
protection feasibility studies, design support of in-house design work
being accomplished by the Government, repair and renovation of
corrosion control and cathodic protection systems, field inspection and
written evaluations of existing facilities, testing of existing
facilities, preparation of permit listings and permit applications, and
Construction Contract Support Services. The term of the Contract will
be 365 calendar days from the date of contract award or until the
$2,000,000 feelimit is reached. The estimated start date is January,
1999. The Government will have the option at the end of the initial 365
calendar days of the Contract to extend the Contract for an additional
365 calendar days or until an additional $2,000,000 in fees have been
awarded. The A-E Selection Criteria will include the following (in
order of importance): (1) Recent Specialized Experience of the Firm
(including consultants) in the evaluation and design of corrosion
control and cathodic protection systems, experience in the application
of Federal, State, County and City environmental regulations,
conducting site engineering investigations and preparation of
Design-Build Requests for Proposals. Do not list more than a total of
ten (10) representative projects in Block 8 of SF 255. Indicate the
consultants from the proposed team, if any, that participated in each
project. (2) Professional Qualifications of the staff to be assigned to
this project in the evaluation and design of corrosion control and
cathodic protection systems, experience in the application of Federal,
Stated, County, and City environmental regulations, conducting site
engineering investigations and preparation of Design-Build Requests for
Proposals. List only the team members who will actually perform major
tasks under this Contract. Qualifications described should reflect each
individual's potential contributions to the projects. (3) Past
Performance on corrosion control and cathodic protection contracts with
Government agencies and private industry in terms of cost control,
quality of work and compliance with performance schedules. Indicate by
briefly describing internal quality assurance and cost control
procedures and indicate team members who are responsible for monitoring
these processes. List recent awards, commendations and other
performance evaluations (do not submit copies). (4) Location in the
general geographic area of SOUTHWESTDIV, provided that the application
of this criterion leaves an appropriate number of firms given the
nature and size of this project. (5) Capacity to accomplish the work in
the required time. Indicate the firms present workload and the
availability of the project team (including consultants) for the
specified contract performance period and indicate specialized
equipment available and prior security clearances. (6) Demonstrated
success in prescribing the use of recovered materials and achieving
waste reduction and energy efficiency in facility design. (7) List the
Small or Disadvantaged or Woman Owned business firms used as primary
consultants or as subconsultants. If a large business concern is
selected for this contract, they will be required to submit a
subcontracting plan that should reflect a minimum of 5% Small
Disadvantaged Business of the amount to be subcontracted out. Those
firms which meet the requirements described in this announcement and
wish to be considered, must submit one copy each of a SF 254 and a SF
255 for the firm and a SF 254 for each consultant listed in block 6 of
the firm's SF 255. One copyof the submittal package is to be received
in this office no later than 3:00 P.M. Pacific Time on the due date
indicated above. Should the due date fall on a weekend or holiday, the
submittal package will be due the first workday thereafter. Submittals
received after this date and time will not be considered. Additional
information requested of applying firms: indicate solicitation number
in block 2b, CEC Contractor Establishment Code) and/or DUINS number (if
any) in block 3a and discuss why the firm is especially qualified based
on the selection criteria in block 10 of the SF 255. For firms applying
with multiple offices, indicate the office which completed each of the
projects listed in block 8 and list which office is under contract for
any contracts listed in block 9. Use block 10 of the SF 255 to provide
any additional information desired. Personal interviews may not be
scheduled prior to selection of the most highly qualified firm. SF
255's shall not exceed 30 printed pages (double sided is two
pages/organizational charts and photographs excluded, exception:
photographs with text will be considered as a page). All information
must be included on the SF 255 (cover letter, other attachments and
pages in excess of the 30 page limit may not be included in the
evaluation process). Firms not providing the requested information in
the format (i.e. listing more than a total of 10 projects in block 8,
not providing a brief description of the quality control plan, not
listing which office of multiple office firms completed projects listed
in block 8, etc.) directed by this synopsis may be negatively evaluated
under selection criteria (3). Firms which design or prepare
specifications for a construction contract or procurement of supplies
cannot provide the construction or supplies. This limitation also
applies to subsidiaries and affiliates of the firm. This is not a
request for proposal. Telegraphic and facsimile SF 255's will not be
accepted. Site visits will not be arranged during the submittal period.
(0160) Loren Data Corp. http://www.ld.com (SYN# 0018 19980611\C-0002.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|