COMMERCE BUSINESS DAILY ISSUE OF JUNE 11,1998 PSA#2114Officer in Charge of Construction, P.O. Box X7, Bldg 1138T1, Marine
Corps Air Ground Combat Center, Twenty Nine Palms, CA 92278-0107 Z -- CROSS CONNECTION PROTECTION, PHASE III (TP-9891MS) SOL
N68711-98-B-1114 DUE 073098 POC Dorothy Brehm/Merry Pilgrim
(760)830-7337 E-MAIL: OICC,MCAGCC,29 PALMS, CA,
dcbrehm@efdswest.navfac.navy.mil. Solicitation Notice -- IFB
N68711-98-B-1114, CORRECT POTABLE WATER TRANSMISSION SYSTEM (TP-9878MS)
-- The work includes furnishing all materials, labor, equipment and
supervision and incidental work for the construction of the following:
a. Replace existing 20-inch and 16-inch butterfly valves with new
butterfly valves at various locations along the two 20-inch
transmission pipelines. b. Replace existing flow meters at Mainside
reservoir with new flow meters and piping. c. Furnish and install new
flow meters, piping modifications and seismic appurtenances at the
Equalization Tank site. d. Furnish and install pressure reducing
stations at various locations on the well transmission pipeline. e.
Furnish and install a new 50,000 gallon welded steel surge tank
including piping, altitude valve, fencing, drain piping, cathodic
protection and all related appurtenances. f. Rehabilitate eleven (11)
existing water wells including, but not limited to, removal of existing
well pumps, motors, piping, electrical and controls; clean, surge and
bail existing well casings; install new submersible well pumps and
motors including piping, flow meters, electrical and controls. g.
Furnish and install a complete SCADA system for the eleven wells and
equalization reservoirs including central station hardware, twelve (12)
remote units, overhead and direct buried fiber optic communication
cable and software -- A Quality Control Program will be required as set
forth in the Contract Specifications. -- NOTE: Bids submitted in
response to this advertisement will be evaluated in compliance with
DFARS Clause 252.219-7008, Notice of Evaluation Preference for Small
Disadvantaged Business Concerns (APR 1996), which is applicable to this
solicitation -- NOTE: Large business concerns are required to submit a
subcontracting plan. -- NOTE: All Federal Contractors must be
registered in the Central Contractor Registration (CCR) database, new
contract awards can only be made to contractors who are registered in
the CCR. CCR Web site: www.acq.osd.mil/ec, request form at
1-800-334-3414. -- Specifications & Drawings available 30 June 1998. --
Site Visit 9:00 AM, local time, 14 July 1998 -- Bid Opening 2:00 PM,
local time 30 July 1998. -- Duration of contract 180 calendar days. --
Estimated Cost Range between $1,000,000 and $5,000,000. -- This
procurement is being issued pursuant to the Small Business
Competitiveness Demonstration Program. -- Sic Code 1711. --
Solicitation packages may be acquired in person from Plan Issue or by
mail -- Telephone requests will not be accepted -- Requests for the
solicitation must be in writing stating solicitation number
N68711-98-B-1114, complete name, address, area code and phone number
and whether bidding as a prime/subcontractor/supplier. -- Mail requests
to OICC, Plan Issue, PO Box X7, MCAGCC, Twentynine Palms, CA 92278-0107
or fax requests to Plan Issue at (760) 830-7436 or EMail requests to
"kmcoe@efdswest.navfac.navy.mil". -- All responsible sources may submit
an offer which will be considered -- Plans and Specifications available
until supply is exhausted. -- Planholders lists will not be faxed.
(0160) Loren Data Corp. http://www.ld.com (SYN# 0167 19980611\Z-0019.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|