|
COMMERCE BUSINESS DAILY ISSUE OF JUNE 15,1998 PSA#2116National Institutes of Health, National Heart, Lung, and Blood
Institute, Contracts Operations Branch, 6701 Rockledge Drive, Room
6100, MSC 7902, Bethesda, MD 20892 66 -- INSTRUMENTS AND LABORATORY EQUIPMENT SOL NHLBI-PS-98-301 DUE
063098 POC Cecilia D. Moarales, Purchasing Agent, (301)435-0369, Debra
C. Hawkins, Chief, Procurement Section, (301)435-0366 The National
Heart, Lung and Blood Institute (NHLBI) intends to purchase the brand
name only items listed below. The followng six items are manufactured
by Carl Zeiss Inc.: 1) One (1) each, part number 4513039901 Axiovert
S100 TV Microscope stand with TV port pointing downwards (split ratio
100% visual/ 100% Video); objective nosepiece 5X H/DIC, and with
integrated 4X turret with bertrand lens, two free positions must be
available for the optovar inserts 1.6X (451373) and 2.5X (451374). 2)
One (1) each, part number 4513759901 Lateral TV adapter for Axiovert
100/135 with 2-position beam selector for either 100% visual, or 30%
VIS/ 70% video. Integrated beam splitter interchangeable with any
commercially dichroic beam splitter, the required size is 26MM X 36MM
X 1MM. 3) One each, part number 451356 Long working distance condenser
NA 0.30 for axiovert 100/135 -- working distance is 70MM, Max.
Illuminated field = 8MM; for brightfield with adjustable aperture iris
diaphragm, and with annular phase diaphragms PH 2; suitable for
brightfield objectives with NA -/< 0.42, in PH 2 for objectives with
NA up to 0.75. Attachment objective 0.55 (only for brightfield) for
objectives with NA-/< 0.60 (40X magnification). 4) One each, part
number 451383 EPI-Fluorescence equipment FL for axiovert 100/135, with
High intensity FL excitation from 360NM for totally homogeneous object
field illumination with adjustable and centerable field iris diaphragm,
3-position slider with open position, open position with BG38 red
suppression filter, and closed position. Shall accept all zeiss HBO/XBO
and Gak100 illuminator systems. 5) two (2) each, part #3800799540
Halogen Bulb 12V, 100W, for LH 447217. 6) One (1) each, part number
440931 CP-Achromat 10X/0.25PH1, WD=5.1. 7) Two (2) each Mercury burner
HBO 100W DC /L2 manufactured by Ushio. 8) (The following three items
are manufactured by Chroma Technology) One (1) each GFP generic BP
filter set, these filters shall work with both wild types and mutants
EXC 450-490, 498DCLP, EM 500-550. 9) One (1) each, 41002 HTQ
Rhodamine/DII FL set. 10) One (1) each 31000 DAPI/Hoechst/AMCA Fl set.
11) (the following three items are manufactured by Dage MTI) One (1)
each CCD-100S CCD camera system without spot mask, 1/3 inch chip
interline CCD, Resolution 570 TV lines, spectral response 380 -750NM,
Pixiels: 768 X485, lens mount C-Mount, black and white video output,
RS-170 interface, the system includes: CCD camera head, 12 V DC power
supply w/cable, instruction manual and requires BNC-BNC cable and the
following accesories: >RC 100 remote control, >207633-01 1/3"
coupler. 12) One each Hr-90 B/W monitor 9"-700 lines. 13) One (1) each
810080-06 6'BNC to BNC cable. 14) (the following four items are
manufactured by Kinetics) One (1) each 400001-010058 Isolated work
station with 30" X 36" X 1" thick vibradamped steel top, white plastic
top lamination, 3" X 7" slot (1/2" radius corners) centered along
table width (3" dimension centered on the 36" length), and centered 17"
from the edge (7" dimension), shall include fixed shelf under table,
air active table 29" height adjustable, 1" up, 1/2" down. 15) One (1)
each GR-36 /9101 guard rail 36". 16) Two (2) SS-10 sliding shelf 10 x
31" white, laminate (requires guard rail). 17) One (1) each EOS
electric outlet strip with GR. 18) One (1) each Micromax 1300Y
interline camera system, small round camera head with C-mount
electronic shuttering PI 1300*1030 CCD, grade 0, high resolution CCD
(6.7*6.7 UM pixels), High QE (42%) at 520NM for FITC, GFP and FURA2,
thermoelectrically cooled CCD to -10C 1 MHZ/12 BIT A/D converter, Real
time RS-170 video output, standard PCI interface card, dynamic range
of 4096 gray levels (12BIT), Winview software for the PC and IPLAB
drivers, IPLAB spectrum software, forced air cooling shroud
manufactured by Princeton Instruments. 19) (the following two items are
manufactured by Scanalytics) One (1) each, IPL-MAC 3.1 spectrum image
processing and analysis software for Powermac, must include:
Acquisition modules for photometrics PVCAM Princeton Instruments,
Hamamatsu #4742-95, Scion LG3/CG7, PCI powermac internal video,
Photoshop acquire plug ins; system requirements: power PC processor,
MAC OS system 73.0 or later, PCI BUS, Monitor with at least 256 colors
and 800 X 600 resolution #1024X768, and RAM 32MB minimum, = / >
64MB. 20) One (1) each, multiprobe MAC Fish image analysis software,
multi wavelength analysis and visualization software, this requires:
IPL-MAC 2.1 spectrum software. 21) One each, #5171 000.171
micromanipulator system manufactured by Eppendorf. This system must
include the following: one micromanipulator #5171, one Transjector 5246
basic, one Microscope adapter, one box of femtotips, one box of
femtotips II, one cellocate 175UM sterile set, one cellocate 55UM
sterile set. 22) Installation and local training. 23) One (1) Freight
charge (including shipping and handling). The Standard Industrial
Classification (SIC) code is 3821, size standard 500 employees. This is
not a small business set aside. The request for quotation (RFQ) will be
due fifteen (15) calendar days from the publication date of this
synopsis. Quotations will be evaluated on conformance to the
government's specifications, delivery time, price, interchange and
compatibility parts with the existing equipment. The offeror must
provide descriptive literature and detailed specifications as part of
the quotation. The Request for Quotation (RFQ) number NHLBI-PS-98-301
will be available upon the publication of this synopsis. Requests for
a copy of the RFQ must be made in writing and the request may be
submitted by FAX transmission to (301)480-3345. Quotations responses
must be in writing and submitted to the National Heart Lung and Blood
Institute, Contracts Operations Branch, Procurement Section, 6701
Rockledge Drive, Rockledge Center Building 2, Room 6143, Bethesda,
Maryland 20892-7902, Attention: Ms. Cecilia D. Morales. FAX quotations
will be accepted only if dated and signed by an authorized company
representative. All responsible sources may submit a quotation, which
if timely received shall be considered by the agency. (0162) Loren Data Corp. http://www.ld.com (SYN# 0346 19980615\66-0007.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|