COMMERCE BUSINESS DAILY ISSUE OF JUNE 18,1998 PSA#2119Commander, Naval Air Warfare Center Weapons Division, Code 210000D, 1
Administration Circle, China Lake, CA 93555-6100 66 -- MASS PROPERTIES MEASURING INSTRUMENT SOL N68936-98-R-0170 DUE
080398 POC Linda Long, Contract Specialist, (760) 939-4232 The Naval
Air Warfare Center Weapons Division, China Lake, CA intends to procure
on a competitive basis (1 ea) Mass Properties Measuring Instrument
which meets the following specifications: (1) Must be capable of
performing a Center of Gravity (CG) measurement along two horizontal
axes in a single setup with better than +/-.001 inch (0.025mm) accuracy
for payloads weighing as little as 4% of machine capacity (6,000 lbs);
(2) Moment of Inertia measurement around a vertical axis with accuracy
better than +/-0.25%; (3) Fully automatic opperation when CG or MOI are
selected on the computer, the entire measurement takes place
automatically; (4) Unbalance moment must be measured directly. Must be
able to have corrections made with the test part mounted and changes
in CG observed immediately; (5) Must utilize an externally pressurized
air bearing system to support the weight of the payload to reduce
wear, and eliminate shock loads; (6) Must NOT utilize a hydraulic pump
system; (6) Must be capable of measuringboth dynamic unbalance and
moment of inertia on a single machine; (8) Must utilize an active
closed-loop rebalance transducer system to detect and compensate for
deflection; (9) The unit must be self calibrating with weights and
distances traceable to NIST; (10) Must come equipped with a dedicated
microcomputer system including monitor and all needed cables, Windows
NT program software; (11) Must be capable of printing a measurement
report and perform the necessary calculation upon the completion of
each test; (12) Mass properties instrument must be classified as
explosion proof, class I and II (SE 9615 option); (13) Price to inlcude
field installation, adjustment and initial testing of the instrument;
(14) Price to include all shipping charges; (15) Must utilize a force
rebalance transducer system. Strain gauge load cells are NOT
acceptable; and (16) Delivery by 30 Sep 98 is highly desired. All
interested and qualified small business sources may submit a proposal
for consideration. Requests for the solicitation must be in writing to
the attention of Linda Long, Contract Specialist, sent either to the
address noted above or telefaxed to (760) 939-7510. See Note(s): 1.
(0167) Loren Data Corp. http://www.ld.com (SYN# 0319 19980618\66-0002.SOL)