Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 23,1998 PSA#2122

DIR OF CONTRACTING WALTER REED AMC, ATTN MCHL Z BLDG T 20, 6825 16TH STREET NW, WASHINGTON DC 20307-5000

65 -- DNA SEQUENCERS, AMPFLSTR PROFILER AND PROFILER PLUS PCR AMPLIFICATION KITS AND AMPLITAQ GOLD SOL DADA15-98-R-0030 DUE 063098 POC Contract Specialist E. CAPERS (202) 782-1285 (Site Code DADA15) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Written proposals are being requested and a written solicitation will not be issued. DADA15-98-R-0030 is issued as a Request For Proposal (RFP). This solicitation documents and incorporates provisions and clauses in effect through Federal Acquisition Circular 90-46. IAW with FAR 6.302-1, Only one Responsible Source and No other Supplies or Services will satisfy agency Requirements. Walter Reed Army Medical Center intends to negotiate on a sole source basis with Perkin and Elmer/ABI for the AmpFLSTR Profiler Plus PCR Amplification Kits and Amplitaq Gold. Standard Industrial Classification is 3826, and the Small Business Size is 500 employees. This requirement is for the purchase of(1) Amplitaq Gold with GeneAmp (5x1000 Units) and PCR buffer and (2) the AMPFLSTR Profiler and Profiler Plus PCR Amplification Kits and Amplitaq Gold. The Kit shall consist of (1) Amplification FLSTR Profiler PCR Amplification Kit (2) Pop 4 Polymer (3) 310 Genetic Analyzer Buffer with EDTA (4) 310 Capillaries 47cm x 50um, Internally uncoated (5) Amplification FLSTR Profiler Plus PCR Amplification Kit (6) Plus Users Manual (7) GeneScan-500 (Rox) Internal lane size standard kit. The STR system must include the following LOCI: (a) locus -- Dye (b) FGA -- 5-FAM(c) VWA -- 5- FAM(d) D3S1358 -- 5-FAM(e) D18S51 -- JOE(f) D21S11 -JOE(g) D8s1179 -JOE(h) Amelogenin -- JOE(i) D7S820 -- NED(j) D13S317 NED (k) D5S818 -- Delivery of the system shall be no later than 10 calendar days after award. The system shall be delivered to the Armed Forces Institute of Pathology Rear building no. 53, Walter Reed Army Medical Center, Main Post, 6825 16th St.,NW; Washington, DC. 20307-5000. FAR Provision 52.212-1, Instruction to offerors -- Commercial Items, applies with the following addenda;paragraphs (h) and (i) of this provision do not apply. The following factors shall be used to evaluate offers: Evaluation will be based (1) Technical (a) Technical capability of the item offered to meet the Government requirement, and (b) Delivery Terms -- ability to meet required delivery schedule and (2) Price. Factors are equal in importance. Offerors shall provide a completed copy of FAR Provision 52.212-3, Offeror Representation and Certifications -Commercial items, and DFARS 252.212-7000, Offeror Representations and Certifications -- Commercial Items with their proposal, with the following addenda: 52.203-2, Certificate of Independent Price Determination. FAR clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items applies including: 52.203-6, 52.203-10, 52.222-26, 52/222-36, 52.222-37, 52.225- 3,52.225-9, 52.225-18, and 52.225-21. DFAR 252.212-7001, Contract Terms and Conditions. Required to Implement Statutes or Executive Orders Applicable to Defense Acquisition of Commercial Items applies including: 252-225-7001, 252-225-7007, 252-225-7036, 252.247-7024. The Defense Priorities and Allocations Systems (DPAS) assigned rating for this procurement is C9B. Walter Reed Army Medical Center intends to award a firm-fixed price contract. Contractor must be able to fulfill the requirments of this notice. All Responsible sources may submit written proposals for consideration by the Government. Written proposals can be mailed or hand delivered to: Walter Reed Army Medical Center, Directorate Of Contracting, Supply and Equipment Branch, 6825 16th St., NW; Bldg T-20, First Floor, Washington, DC 20307-5000 by close of business, 15 business days after published date. Written proposals must include the following information: the solicitation number, company name, point of contact, address, phone number, fax number, business size, DUNS number, CAGE code, unit price, total extended price, payment terms and remittance address. For additional information contact Edna Taylor-Capers (202) 782-1171 or Earl Muse. See number Note 22. (0170)

Loren Data Corp. http://www.ld.com (SYN# 0324 19980623\65-0006.SOL)


65 - Medical, Dental and Veterinary Equipment and Supplies Index Page