|
COMMERCE BUSINESS DAILY ISSUE OF JUNE 23,1998 PSA#2122SPAWARSYSCEN, Charleston, PO Box 190022, North Charleston, SC 294=
19-9022 81 -- TRANSIT CASES -- POTENTIAL SOURCES SOUGHT SOL N65236-98-R-0457
DUE 062698 POC Peggy McCracken, Code 1116PM, (803)974-5936, =
"mccrackp@spawar.navy.mil"; Contracting Officer, C. O. Walsh E-MAIL:
SPARWARSYSCEN Charleston, mccrackp@spawar.navy.mil. SPAWARSYSCEN
Charleston is conducting a market survey to determine = the = existence
and interest of possible sources who possess the capability of =
producing and configuring five different types of transit cases for a
tot= al = maximum quantity of 2900 with the following capabilities: I.
STANDARD = CHARACTERISTICS. Cases will be used to transport fragile
equipment by mil= itary = forces while in combat and combat simulated
situations. The construction= of the case must be of a durability
rating that will safeguard equipment while b= eing = transported
through all types of terrain and climates by any and all mode= s of =
transportation utilized by the U.S. Armed Forces. Ultimate space
utiliza= tion, = to lessen the exterior footprint, is necessary. This
will include storag= e in = lids when possible. All cases will be
Forest Green with a matte or flat = finish. Non-shiny finishes are
required on ALL metal surfaces. Cases must be wat= er = resistant to
keep interior and components dry under sustained wet weather= =
conditions. II. SPECIFIC CASE CONFIGURATIONS. (A) CASE A: Case A will
be= = capable of accepting a standard 3/8" diameter padlock. The case
will be = engineered to house the following equipment and all equipment
must be = operational from the case: IBM ThinkPad 770 (14.1" screen),
IBM "Select a= base" = port replicator, HP Deskjet 340CV Printer, Storm
Pagescan USB scanner, Io= mega = Ditto Max (Model #10662), Logitech
Trackman Marble, trackball, Uniterrupt= able = power supply (specific
model TBD) or power protection strip. Additionally=, the = location and
placement of the laptop, within the case, must allow access = to and =
use of the following list of peripheral items; Graystone Peripherals,
TA-= 50 = PCMCIA Extender Card, Removable HDD (IBM), Removable CD ROM
(IBM), Remova= ble FDD (IBM), SCSI Adapter Card (PCMCIA, Adaptec
1460B), Intel Etherexpress Pro/= 100 = Mobile adapter, Model #
MBLA1600, CMS Easy -Plug/Easy-Go 520MB PCMCIA HDD= =2E = Size: The
smallest footprint available, that willaccommodate necessary =
equipment and allow for proper airflow, is desired. The following is
the = maximum size allowed: Length: 24", Width: 30", Height: 14";
Weight: 30 lbs. (Not = including computer hardware, peripherals, and
power supply). Access: = Top-opening, suitcase style, hinged. Material:
Shell -- Non-metallic, syn= thetic, molded. Hardware: Handle "A" --
Handles will be of sufficient strength t= o lift = and support case
fully integrated with components. Black in color. Locati= on: 1 = ea.
on front and right sides; Handle "B" -- Retractable to overall dimensi=
ons of = case. Mounted on case bottom. Extends to right. To be used in
conjunct= ion = with the wheels in "pullcart" fashion. Black in color.
Wheels -- Fixed a= xle, 2 = ea. bottom left. Black in color. Hinges --
Sufficient strength to hold one= and = one half times the weight of
identified equipment, manuals, documentation=, etc. = in lid. Black or
forest green in color. Open Lock Mechanism -- Locks lid = open in ~
110o. Hinges and Open Lock Mechanism will allow easy lid removal witho=
ut the = use of tools. Latches -- 2 ea. front -- minimum, 1 ea. right
and left side = = minimum. Black or green in color. Environmental:
Pressure Relief = Valve -- Manual, push button. Adequate to relieve
pressure from case interi= or = during air transportation. Able to
withstand temperature range of -10o t= o +150o F. Water proof/
resistance -- Interior and all exterior connections to rema= in dry =
under sustained wet weather conditions. External Connections: Access --
Th= readed, screw down waterproof cover. Connectors recessed a minimum
of 1". Power -- = 1 ea. = Receives equipment end of standard 3-prong
computer power cable. Network-= -- -1 ea. = RJ-45 receptacle. Interior
Enclosure: The enclosure will be shock mounte= d. = Shock mounts will
be rated to adequately support enclosure and hardware = components.
Quantity will be 4 each and attached from case to enclosure a= t =
corners or sides. Enclosure -- Supports hardware components (identified
abo= ve). = Supported solely by shock mounts. Non-ferrous metallic.
Flat black or mat= te = finish on all surfaces. Laptop Support-open top
platform supports laptop = and = port replicator. Platform moves in a
forward and reverse direction by use= of = slides and other mechanical
means of platform movement, to allow access t= o = interior-mounted
hardware components. In forward and locked position, lap= top =
platform extends over the forward edge of the open case. Platform
assembl= y = remains attached to the enclosure in all positions. Port
replicator will = be hard mounted to laptop platform. Printer, Scanner,
Ditto Max, and power source= will = be hard mounted in bottom of
enclosure and permit proper paper flow and a= ccess = to all controls,
connections, print cartridges, etc. Allows complete = uninterrupted
operation without removal. Use of hook and loop tape and fo= am =
materials is not desired. NOTE: Enclosure mounting design shall allow
com= puter = and peripheral device dimensions to vary +/- 5% in total
volumetric area.= Lid = Storage Area -- Durable and flexible, briefcase
style system of = pouches/compartments mounted to the case lid. All
pouches/compartments wi= ll be = secured with a zipper, loop and hook
tape, snaps, etc. Separate storage f= or the = following: IBM FDD, HDD,
CD ROM Drive -- 1 ea, PCMCIA Cards -- 3 ea, 3 =BD" = Diskettes -- 1 bx,
CD ROM Disks -- 6 ea, Ditto cartridge -- 2 ea, IBM laptop ba= ttery, =
printer paper (Std) -- =BC Ream, Technical Manuals -- 1 ea 2" Binder,
and Mis= c Office = Supplies -- 48 in3 (approx). Electronics: Power
bricks and cords -- Separat= e power bricks and excess cord containment
compartments built into the bottom of = the = enclosure. Flat or black
matte in color. Non-ferrous metallic material. L= ocated = adjacent to
the power supply. Power cables -- all power cables are to run f= rom =
equipment to power supply via the containment compartment. Routing
shall = be on = the surface of theenclosure. Cutouts through the
enclosure base will per= mit the use of removable and reusable cable
restraint devices. Port replicator po= wer = cable routing will be with
the data cables. Data cables -- all data cables= will = be routed from
the printer, scanner and tape backup drive to the front of= the =
case, and data cables will further be routed along the bottom of the
lapt= op = support to the Port replicator. External connections -- all
external conne= ctions = will be made via the external weather-tight
access. These connections are= = defined as follows: Standard 3-prong
110 VAC plug receptacle passes power= to = 3-prong male computer cable
receptacle under access cover. Network conne= ction = consists of
RJ-45 coupler designed to receive the RJ-45 connector inside = the =
case located under the access cover. NOTE: Standard Characteristics for
C= ases = "B" through "E": (1) Cases will be of the same manufacturer
and design. = (2) = Water resistant to keep interior and components dry
under sustained wet w= eather = conditions. (3) Dimensions. The case
will be of sufficient size to prote= ct and = contain the equipment
identified to be transported/stored in each case. = Each = case shall
be designed to maintain a low center of gravity and equal weig= ht =
distribution. Not to exceed minimum size required for content
protection= =2E (4) = Exterior color will be Forest Green and flat or
matte finish. (5) Access= will = be top opening. (6) Material: Shell:
Non-metallic, synthetic, molded, r= ibbed = for stacking. Hardware;
Handles will be of sufficient strength to lift an= d = support case
fully integrated with components. Location: 1 each on all s= ides =
(spring return bale type is preferred). Latches: Sufficient all sides.
= (7) = Interior. Non-residual, high density, non-absorbent foam with
custom cut= = cavities. (B) CASE B: Case B will be engineered to
transport the followin= g = equipment: 10 Base-T Hub (est. size 14x6x3"
2 lbs.), additional cables, p= rinter = cartridges, battery charger for
IBM 770, additional batteries for IBM 770=, = technical manuals, laptop
softcase, inverter (Mfg. and model TBD. Est. s= ize = 14x4x6" 8-15
lbs), inverter cable (Est. size 18 C.I., 10 lbs.). (C) CASE= C: = Case
C will follow the same specifications as listed above. Case C will =
be used to safely store and transport a Liquid Crystal Display.
Manufacturer NEC= =2E = Model LCD 2000. (D) CASE D: Case D will follow
the same specifications as= listed above. Case D will be used to
safely store and transport a printer. = Manufacturer Hewlett Packard.
Model 890C. Space for a 6' printer cable = and = spare ink cartridges
will also be required. (E) CASE E: Case E will follo= w the = same
specifications as listed above. Case E will be used to safely store=
and = transport a projector. Manufacturer Toshiba. Model TLP-511A and
spare b= ulb. = (F) Estimated quantities as follows: Case A 500-900,
Case B 500-900, Case= C = 100-500, Case D 75-250, and Case E 120-350.
(G) Delivery: DELIVERY IS CRI= TICAL. = Following is the most lenient
schedule allowed. Dates stated are ARO. D= ates = are cumulative,
quantities are NOT. Improved delivery is desired. CASE = A: 50 = ea in
30 days, 50 ea in 45 days, 100 ea in 60 days, 100 ea in 90 days, 10=
0 ea in 120 days, 100 ea in 150 days, and Balance in 180 days; CASE B:
50 ea in 3= 0 days, 50 ea in 45 days, 100 ea in 60 days, 100 ea in 90
days, 100 ea in 120 day= s, 100 = ea in 150 days, and Balance in 180
days; CASE C: 20 ea in 30 days, 20 ea = in 45 = days, 20 ea in 60 days,
20 ea in 90 days, 20 ea in 120 days, and Balance = in 180 = days; Case
D: 25 in 30 days, 25 in 45 days, 25 in 60 days, Balance in 180= days;
= and CASE E: 20 ea in 30 days, 20 ea in 45 days, 40 ea in 60 days, 40
ea i= n 90 = days, and Balance in 180 days. (H) Control Drawings: The
contractor shal= l = furnish control drawings within 60 days ARO, in
compliance with ASME Y14.= 24M, = for items not covered by a
military/industry specification and items for = which = the Government
has not paid for the design development. This includes = commercial
off-the-shelf (COTS), non-developmental items (NDI), and contr= actor
= limited rights items. Sufficient information shall be provided to
enable= = competitive reprocurement of a physically and functionally
interchangeabl= e item. (I) Special Considerations: Due to the
complexity of CASE A, and the crit= icality of meeting the specified
delivery schedule, the contractor must be willin= g to = allow a
Government Technical Representative to be present during initial =
design = and fabrication. This will alleviate the possibility of
unnecessary dela= ys due = to communication "lag" times. INFORMATION
SOUGHT: General -- Firms are in= vited = to submit appropriate
technical documentation, general drawings, digital = pictures,
literature, brochures, and references to support that they poss= ess
the required capabilities necessary to meet or exceed the required case
= specifications and critical delivery schedule. Pertinent information
shou= ld = address current capabilities and practices, quality
assurance procedures,= = production quantity, delivery considerations,
years of corporate experien= ce in = the production of transit cases,
and current association(s) with case sup= pliers. Specific --
Responses must include the following: (1) name and address of = firm;
= (2) size of business: average annual revenue for past 3 years and
number = of = employees; (3) ownership: Large, Small, Small
Disadvantaged, 8(a); and/or= = Woman-Owned; (4) number of years in
business; (5) two points of contact: = name, = title, phone, fax and
e-mail; (6) DUNS Number; (7) affiliate information:= parent
corporation, joint venture partners, potential teaming partners, prime
= contractor (if potential sub) or subcontractors (if potential
prime), (8)= a list of at least 5 customers (contracts) covering the
last 3 to 5 years: highl= ight = relevant work including a summary of
work performed, contract number, con= tract = type, dollar value for
each customer reference, and customer point of con= tact = with phone
number(s). Past performance MUST identify similar contract aw= ards in
both technical expertise and scope. WHERE TO SUBMIT INFORMATION:
Mailed = responses shall be submitted to SPAWARSYSCEN Charleston, Code
1116PM, PO = Box = 190022, North Charleston, SC 29419-9022; Shipped
responses shall be deli= vered = to Receiving Officer, SPAWARSYSCEN
Charleston, 1639 Avenue "B", North = Charleston, SC 29405-1639; Hand
carried responses shall be delivered to = SPAWARSYSCEN Charleston,
Naval Weapons Station South Side Annex, Attn: Co= de = 1116PM, Bldg.
3147, One Innovation Drive, Hanahan, SC 29406; or by elect= ronic =
mail to mccrackp@spawar.navy.mil. WHEN TO SUBMIT: No later than 3 p.m.,
E= astern = Standard Time, 26 June 1998. NOTICE REGARDING SOLICITATION:
This notice = is for = information and planning purposes only and is
not to be construed as a = commitment by the Government. This is not a
solicitation announcement fo= r = proposals and no contract will be
awarded from this announcement. If = satisfactory responses are
received, a solicitation may be issued for an = indefinite delivery,
indefinite quantity type contract with Firm Fixed-Pr= ice = delivery
orders. NOTICE REGARDING PROPRIETARY INFORMATION: All submitted= =
materials will be designated for Government use only. Respondents will
n= ot be = notified of the results of the evaluation. Respondents
deemed fully qual= ified = will be considered in any resulting
solicitation for the requirement. The= = Government reserves the right
to consider a Small Business Set-Aside Or 8= (A) = Set-Aside based on
responses hereto. The applicable FSC Code is 8145 and= the = SIC Code
is 3089 with a size standard of 500 employees. OTHER: NO REIMBU=
RSEMENT WILL BE MADE FOR ANY COSTS ASSOCIATED WITH PROVIDING
INFORMATION IN RESPO= NSE TO = THIS ANNOUNCEMENT AND ANY FOLLOW-UP
INFORMATION REQUESTS. = (0170) Loren Data Corp. http://www.ld.com (SYN# 0354 19980623\81-0003.SOL)
81 - Containers, Packaging and Packing Supplies Index Page
|
|