COMMERCE BUSINESS DAILY ISSUE OF JUNE 30,1998 PSA#2127Defense Special Weapons Agency, Acquisition Office (FCA), 1680 Texas
St., SE, Kirtland, AFB, NM 87117-5669 66 -- DIGITIZERS SOL DSWA02-98-Q-0072 DUE 071398 POC Toni Sandoval,
Contract Specialist, (505) 846-8830 or Patricia M. McDaniel,
Contracting Officer, (505) 846-8799 This is combined
synopsis/solicitation for commercial items prepared in accordance with
the format in Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; quotations are being requested and a written
solicitation will not be issued. Solicitation Number DSWA02-98-Q-0072
is being issued as a Request for Quotation. The Standard Industrial
Code is 3825 and the business size standard is 500. This solicitation
incorporates provisions and clauses effective through Federal
Acquisition Circular 97-04. This requirement is for a fixed-price
contract for the following: CLIN 001: 1 GHz Digitizer, 4 ea; CLIN 002:
250 MHz Digitizer, 11 ea; CLIN 003: 200 KHz Digitizer, 1 ea; CLIN 004:
VXI Mainframe, 3 ea; CLIN 005: MXI Computer Interface, 1 ea; CLIN 006:
VXI-GPIB Computer Interface, 2 ea, CLIN 007: Five year calibration
service for CLINs 001 thru 003, CLIN 008: All units shall come complete
with Owner's service manuals containing operating instructions,
maintenance information, and programming references and complete
specifications. DESCRIPTION: CLINs 001-006 shall conform to the
following minimum salient characteristics: CLIN 001: Analog Bandwidth
= DC-1GHz per channel, Format: VXI, C-size, no more than double wide,
Number of Channels per Unit: 4 or greater, Sample Rate: Programmable
sample rate variable & selectable from 5 samples/second t o 5
Gsamples/second or greater per channel, Full Scale Ranges: From 10
millivolts to 100 volts per channel selectable in certain increment
sequence, Vertical ADC resolution >= 8 bit per channel, Input
Impedance: 50 ohms, 1 Mohm selectable, Input Offset: Full scale
minimum, Input Accuracy: +/-2%, Input Filter: Selectable low pass
filters, Record Length: Programmable from 256 points to 15 Kpoints per
channel, Time Base: 10 MHz internal and external, Pre-trigger up to
the record length, Post-Trigger delay from 0 to 200 seconds or greater
& selectable, Acquisition Modes: Normal and auto-advance. Number of
records programmable with each record time stamped, Trigger Sources:
Internal, external, and VXI bus, Trigger Types: Edge delayable by time
and number of events, Trigger Modes: normal, single, and auto, Trigger
Level: Programmable +/- full scale internal and +/- 1 volt external,
Trigger Coupling: DC and AC internal trigger and DC with a 50 ohm
impedance external trigger input, Trigger Slope: Programmable positive
and negative, Trigger Width: 1 nanosecond to 1 second or greater,
selectable, Internal calibration capable, Delay Between Channels: Not
greater than 100 picoseconds, Fiducial Input: External input allows a
signal to be superimposed on the channel 1 data, Arm: Internal,
External or from VXI bus, Completely programmable, Power Consumption:
110 Watts less per unit, Operating Temp: 32-120 degree F, Operating
Humidity: 95% relative (non-condensing), Software Drivers: 1) VXI
plug&play in WINNT framework: 16 bit an 32 bit. Soft front panel. 2)
Multi Digitizing System (MDS) developed by MIT (ifavailable), Built in
Signal Processing & Calculation functions & function library. CLIN
002: Analog Bandwidth: DC-250 MHz, Format: VXI, C-size, no more than
double wide, Number of Channels per Unit: 4 or greater, Sample Rate:
Programmable sample rate variable & selectable from 5 samples/second to
1 Gsamples/second or greater, Full Scale Ranges: From 10 millivolts to
100 volts per channel selectable in certain increment sequence,
Vertical ADC resolution >= 8 bit per channel, Input Impedance: 50
ohms, 1 Mohm selectable, Input Offset: Full scale minimum, Input
Accuracy: +/-2%, Input Filter: Selectable low pass filters, Record
Length: Programmable from 256 points to 15 Kpoints per channel, Time
Base: 10 MHz internal and external, Pre-trigger up to the record
length, Post-Trigger delay from 0 to 200 seconds or greater &
selectable, Acquisition Modes: Normal and auto-advance. Number of
records programmable with each record time stamped, Trigger Sources:
Internal, external, and VXI bus, Trigger Types: Edge delayable by time
and number of events, Trigger Modes: normal, single, and auto, Trigger
Level: Programmable +/- full scale internal and +/- 1 volt external,
Trigger Coupling: DC and AC internal trigger and DC with a 50 ohm
impedance external trigger input, Trigger Slope: Programmable positive
and negative, Trigger Width: 1 nanosecond to 1 second or greater,
selectable, Internal calibration capable, Delay Between Channels: Not
greater than 100 picoseconds, Fiducial Input: External input allows a
signal to be superimposed on the channel 1 data, Arm: Internal,
External or from VXI bus, Completely programmable, Power Consumption:
85 Watts or less per unit. CLIN 003: Analog Bandwidth = DC-200KHz per
channel, Format: VXI, C-size, no more than Double wide, Number of
Channels per Unit: 16 or greater, Sample Rate: Programmable sample rate
variable & selectable from 1 samples/second to 200K samples/second or
greater, Full Scale Ranges: From +/-200 millivolts to +/-20 volts per
channel selectable in certain increment sequence, Vertical ADC
resolution >= 16 bit per channel, Signal Input Type: Differential,
and Single ended by grounding the negative side of the input, Input
Impedance: 100 Kohms, +/-1% each side, Input Offset: Full scale
minimum, Input Accuracy: +/-1%, Record Length: programmable, 64K points
or greater per channel, Pre-Trigger and Post-Trigger: Pre-Trigger &
Post-Trigger up to the record length, Acquisition Modes: Normal and
auto-advance. Number of records programmable with each record time
stamped for each 4 channel group. Trigger Sources: Internal, external,
and VXI bus, Trigger Types: Edge delayable by time and number of
events, Trigger Modes: Normal, single, and auto, Trigger Level:
Programmable +/- full scale internal and +/- 1 volt external minimum,
Trigger Coupling: DC & AC internal trigger and DC external with 50 ohm
impedance trigger input, Trigger Slope: Programmable positive and
negative, Trigger Width: 1 nanosecond to 1 second or greater,
selectable, Internal calibration capable, Delay Between Channels: Not
greater than 100 picoseconds, Front Panel Inputs: one each of external
clock, trigger, sync, & Arm, Arm: Internal, External or from VXI bus,
Completely programmable, Software Drivers: 1) VXI plug&play in WINNT
framework: 16 bit and 32 bit. Soft front panel, 2) Multi Digitizing
System (MDS) developed by MIT (if available), Built in Signal
Processing & Calculation functions & function library, Power
Consumption: 50 Watts less per unit, Operating Temp: 32-120 degree F,
Operating Humidity: 95% relative(non-condensing). CLIN 004: Size: C,
Compliant with VXIbus Specifications Revision 1.4, Backplane: Solid
state auto-configure, Usable Power: 875 watts, Cooling: Automatic fan
control, shutters automatically close to prevent air flow to unused
slots, Monitoring: Front panel display and computer monitoring of
critical parameters, Rack Mount: All necessary hardware for mounting in
a standard 19 inch equipment rack, Operating Temp: 32 to 120 degrees F,
Power: US standard (115v +/- 10%), 60 Hz. CLIN 005: Type: Multisystem
Extension Interface bus (MXI), Components: Computer PCI plug-in board,
VXI C-size slot 0 module, Cable for connecting PCI card to slot 0
module, Interface software, Features: VXI resource manager,
Message-based and register-based communications, Block transfers from
VXI memory to computer memory, Direct access to VXI memory, Slot 0
module has inputs for external trigger and external 10 MHz clock. CLIN
006: Type: General Purpose Interface Bus (GPIB), IEEE 488.2
Compatible, Single Wide VXI C-size slot 0 module, Interface software,
Features: VXI resource manager, Links the industry-standard IEEE 488
bus an the VXIbus by transparently converting GPIB signals and
protocols to VXI bus signals and protocols, Message & register based
communications, VXI commander and/or servant functionality, Block
transfers from VXI memory & GPIB at high speeds, This slot 0 module
controls VXI trigger lines. These items are for delivery to Kirtland
AFB, NM within five weeks ARO. The following FAR clauses apply to this
acquisition and are incorporated by reference: FAR 52.212-1,
Instructions to Offerors-Commercial Items; FAR 52.212-2,
Evaluation-Commercial Items: The specific evaluation factors are (1)
technical capability of the items offered to meet the Government
requirement, (2) price and (3) past performance -- each offeror shall
provide the name and points of contacts of the last three sales to whom
they have provided the same or similar items. FAR 52.212-3, Offeror
Representations and Certifications-Commercial Items -- OFFEROR MUST
INCLUDE A COMPLETED COPY OF THIS PROVISION WITH ITS OFFER; FAR
52.212-4, Contract Terms and Conditions-Commercial Items; and FAR
52.212-5, Contract Terms and Conditions Required to Implement Statutes
of Executive Order-Commercial Items. Contractor shall provide a copy
of their commercial warranty for CLINS 004-006. Contractor shall
provide, with their quote, any descriptive literature, brochures, or
adequate information to determine whether the offered items will meet
the terms and conditions cited above. The offer must: (1) be for the
items described above; (2) be FOB Destination to this agency; (3)
included a delivery schedule and the discount/payment terms; (4)
include name of and be signed by an authorized company representative
along with telephone number, facsimile number. (5) include their
taxpayer identification number (TIN), Cage Code Number, and DUNS
number. This acquisition will be processed in accordance with the
Simplified Acquisition Procedures. This will be a DO-A70 rated order.
Offers are due by 13 JUL 98 no later than 2:00 p.m. (local time) to:
Toni Sandoval, FCDSWA/FCA, 1680 Texas Street SE, Kirtland AFB, NM
87117-5669. All responsible sources may submit an offer which shall be
considered by this agency. For solicitations issued after 31 May 1998,
DoD will no longer award contracts to contractors not registered in the
Central Contractor Registration (CCR) data base. Registration may be
done by accessing the CCR via the Internet at http://ccr.edi.disa.mil/.
Posted 06/26/98 (0177) Loren Data Corp. http://www.ld.com (SYN# 0331 19980630\66-0015.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|