Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JULY 21,1998 PSA#2141

Fleet & Industrial Supply Center, Regional Contracts Dept, Attn: Bid Officer/Code 210A94, 937 N. Harbor Drive, Suite 212, San Diego, CA 92132-0212

59 -- TRANSIENT VOLTAGE SURGE SUPPRESSORS SOL N00244-98-R-0113 DUE 082198 POC david_chesnut@fmso.navy.mil (619) 532-3955 WEB: Click here for information on FISC San Diego, including, http://www.sd.fisc.navy.mil. E-MAIL: Click here to request a hard copy of the solicitation, fiscsd_bid_officer@fmso.navy.mil. The Fleet and Industrial Supply Center San Diego (FISCSD) intends to negotiate a fixed price supply contract for internally fused Transient Voltage Surge Suppressors (TVSS) with parallel threshold suppression network of low impedance surge path circuit design. TVSS units shall provide the following minimum performance parameters: (1) Remote Alarm -- Form C, N/O or N/C contacts, internally mounted terminal strips, weatherproof fitting provided. Contact rating: power -- 60W, 100VA max, voltage -- 150VDC or 220 VAC max. Current -- 4 amps max; (2) Input Power Frequency -- 50-420Hz; (3) Response Time -- less than or equal to 1 nonosecond; (4) Protection Modes -- Enhanced All: Dedicated L-L (normal mode) dedicated L-G (common mode); (5) Circuit Diagnostics -- LED indicators (green), 1 per phase, normally on; (6) Circuit Interrupt -- Internal, replaceable class J fuses, 3 each; (7) Enclosure -- NEMA 4 -- weatherproof (hinged lid) seam welded brackets and mounting feet; (8) Connection Method -- Internal wire clamping box terminals: phases, neutral and ground #6-1/0 wire; (9) Mounting Method -- multi-point feet and conduit fitting (conduit fitting placed at time of installation to assure minimum parallel lead length; (10) Shipping Weight -- 14 kg (30 pounds) max; (11) Dimensions -- Approximately 11.5H x 9W x 7D. 480V TVSS units shall have continuous operating voltage (rms) of 550 L-L/550 L-G; surge current rating (amps/phase) of 200kA; energy dissipation (joules/phase) of 4,800; and ANSI/IEEE C62.41-1991 Let-Through Voltage Test (Cat B3/C1 Impulse 6,000V, 3000A static) of 1,750 L-L/1,750 L-G. 120V TVSS units shall have continuous operating voltage (rms) of 150 L-L/150 L-G; surge current rating (amps/phase) of 200kA; energy dissipation (joules/phase) of 1,800; and ANSI/IEEE C62.41-1991 Let-Through Voltage Test (Cat B3/C1 Impulse 6,000V, 3000A 90 degree phase angle) of 675 L-L/675 L-G. TVSS units shall be manufactured under UL 1449/CUL standards for shipboard and shore based power distribution applications. FISCSD anticipates approximately 39 each 480 volt units and 168 each 120 volt units. Manufacturers that have not passed MIL-SPEC-1399 testing will be required to propose an additional 1 each 480 volt unit and 1 each 120 volt unit for destructive first article testing. Manufacturer must be certified to ISO 9001 standards. The UNRESTRICTED commercial solicitation (FAR Part 12) will be issued on or around 04 August 1998. Posted 07/17/98 (W-SN225248). (0198)

Loren Data Corp. http://www.ld.com (SYN# 0383 19980721\59-0012.SOL)


59 - Electrical and Electronic Equipment Components Index Page