COMMERCE BUSINESS DAILY ISSUE OF JULY 21,1998 PSA#214145CONS, 1201 Edward H. White II St, MS 7200, Patrick AFB, FL
32925-3237 66 -- XRF SPECTROMETER SYSTEM SOL F08650-98-TB-132 POC Ms Lear Matus,
Contract Specialist (407) 494-9512/Mr Jimmy McDaniel, Contracting
Officer (407) 494-7227 A market survey is being conducted to identify
firms to provide and install an XRF Spectrometer System, Philips
Electronic Instruments Model PW2400 or equal. System should be
compatible with existing multiple analysis crystals. System and options
as follows: 1 each Sequential X-ray Spectrometer 3KW, 60kV, 125mA; 1
each X-ray Tube: Ceramic SST 3kW, 6kV, 125mA, 150 micro BE End Window;
2 each sets of 5 flow Counter Windows 2 micron PP; 2 each Primary Beam
filter 100 micron Brass; 3 each Primary Beam Filter 200 micron A1; 1
each Primary Beam Filter 300 micron Brass;1 each Primary Beam Filter
750 micron A1; 1 each Beam Stop 1mm Pb; 1 each Primary Collimator, High
Resolution, 0.15mm Spacing; 1 each Primary Collimator, Medium
Resolution, 0.30mm Spacing; 1 each Primary Collimator, High Intensity,
0.70mm Spacing; 1 each Analyzing Crystal LiF200; 1 each Analyzing
Crystal PE; 1 each Synthetic Multilayered Monochromator PX1; 1 each
SuperQ Analytical Software MS Windows ; 1 each Computer, Gateway 2000,
GPS-200 MHz(with prescribed options); 1 each HP Deskjet 870Cxi with
Cable; 1 each R175 Water Cooled Water Chiller; 1 each Air Preparation
Kit; 1 each Switch Box and Modem F/Remote Diagnostics; 1 each 47
Element 40mm Monitor disk; 1 each He Tank Adapter; 1 each He Flush
System for Liquids; 1 each Set of 5 He Liquid Cups, 2400/2600; 1 each
Inserts (includes 100 KAT P-2 cells); 1 each Semi-Q Software with
Standards; 1 each Be Filter (substitute at install for one of above);
On-site Training (approximately 2.5 days); Shipping FOB Destination.
The applicable SIC code and size standard are 3826/500. Firms
responding to this synopsis should provide contract numbers,
descriptions of items ordered, and points of contact/phone numbers for
contracts under which identical/similar items are being provided to
other commercial or government customers, along with any other
pertinent information which would enable the government to assess your
firm's products. Firms must respond to this announcement within 10
days from the date of publication and (1) state whether they are a
small or large business based on the size standard above, and (2)
indicate if a small disadvantaged or woman-owned business, or 8(a)
firm. The government reserves the right to set this acquisition aside
for small businesses or 8(a) firms based on the responses received.
This synopsis is for planning purposes only and does not commit the
government to pay for the information requested, issue a solicitation,
or award a contract. No technical or solicitation documents exist now.
Submit written responses to 45 CONS/LGCSA, Attn: Ms Lear Matus, 1201
Edward H. White II St, Patrick AFB, FL 32925-3237. Phone calls will not
be accepted. ***** Posted 07/17/98 (W-SN224776). (0198) Loren Data Corp. http://www.ld.com (SYN# 0426 19980721\66-0016.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|