COMMERCE BUSINESS DAILY ISSUE OF JULY 23,1998 PSA#2143Sacramento Alc/Pkxd, 3237 Peacekeeper Way/Suite 17, Mcclellan Air Force
Base Ca 95652-1060 58 -- REPLACEMENT OF AUTO MESSAGE SYSTEM DUE 090998 POC For copy,
contact the info office indicated., For additional information contact
Pullen.0kd/Pkl-2/[916]643-3571 Request industry comments on the
following proposed salient characteristics for the acquisition of a
replacement air traffic control tower voice recorder for the AN/GSH-59
Automatic Terminal Information System (ATIS). The current ATIS is the
CDD-1000, formerly manufactured by Granite Bay, which is now out of
business. The replacement for the ATIS voice storage and announcement
system shall meet the following characteristics: 1) The system shall
contain a Main Control Unit (MCU) (FAA Type #10012) and a Remote
Control Unit (RCU)(FAA Type #10012/2). The two assemblies shall operate
in parallel and have identical functions. Recording, monitoring and
continuous on-line modes shall be controlled from either the main
assembly or the remote assembly. 2) The system shall be capable of
digitally storing a 30-second announcement. The storage device shall
not be a disc drive nor a tape mechanism. 3) The system shall be
capable of continuously transmitting a recorded announcement to
broadcast facilities and telephone lines. Announcements shall repeat
automatically at the end of the announcement. 4) Announcements shall be
recorded through a push-to-talk, plug-in telephone-like handset (FAA
Type #10012/5). There shall be automatic squelch circuitry to mute
background noise while recording announcements. 5) A front panel
monitor volume control shall be available. 6) The input power shall be
117 VAC +/-10%, 50-60 Hz. A removable, 6-foot minimum, three-prong,
power cord shall be supplied. 7) Battery back-up shall be provided to
sustain the recorded announcement during brief power outages of up to
five minutes. An internal automatic battery recharging circuitry shall
be incorporated. Rechargeable batteries shall be Nickel-Cadmium type.
Batteries shalll be provided and be a commercial off-the-shelf type.
8) No Preventive Maintenance shall be required. 9) A "Users Operations
and Maintenance Manual" per TM 86-01 shall be provided. [The following
apply to the MCU only.] 10) The MCU shall be capable of being mounted
in a standard19-inch rack. The MCU shall be capable of connecting a
minimum of 3 each 600 ohm telephone connections. 11) The MCU shall
incorporate exterior terminals for remote connection. 12) The MCU shall
be capable of full operation with battery reserve for up to five
minutes. The MCU shall have an internal battery charging capability.
The MCU shall have a visual alarm when going to battery. The MCU shall
have the capability to remove/install batteries while the system is on
and operating. [The following apply to the RCU only.] 13) The RCU shall
be capable of all recording, monitoring and control functions present
in the MCU. 14) The RCU shall be capable of remote operation up to a
minimum of 1000 feet with standard shielded cable connections. 15) The
RCU shall be capable of being mounted on a panel or console. Comments
may be faxed to (916)643-6356, Attn: Donald C. Pullen. The approximate
issue/response date will be 20 Aug 98. Posted 07/21/98 (I-SN226076).
(0202) Loren Data Corp. http://www.ld.com (SYN# 0346 19980723\58-0012.SOL)
58 - Communication, Detection and Coherent Radiation Equipment Index Page
|
|