Bureau of Reclamation, Lower Colorado Regional Office, 400 Railroad Ave, Boulder City, NV 89005-2422

61 -- ELECTRICAL DISTRIBUTION PANELS WITH STARTERS AND BREAKERS SOL 98-SQ-30-00038 DUE 082098 POC Albert J Richard 702-293-8601 E-MAIL: contracting officer via e-mail, arichard@lc.usbr.gov. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. Solicitation 98-SQ-30-0038 is issued as a Request for Quote (RFQ) and incorporates provisions and clauses in effect through Federal Acquisition Circular 97-06. This solicitation is issued under the Simplified Acquisition Procedures (SAP) for Small Business-Small Purchase Set-Aside (100%). Standard Industrial Classification is 5063 and the Business Size Standard is 500 employees. The following items are required to replace out-dated original equipment in two intake towers at Hoover Dam. The following two electrical distribution panels must fit in an existing concrete recess which is 6 feet wide horizontally, 1 foot 4-1/4 inches deep, and 4 feet 1-1/4 inches high vertically, one per intake tower. The 480 VAC distribution panel will be mounted sideways with the main breaker on the left side and over half of all the subbreakers will be feeding loads downward towards existing conduits in the concrete intake towers. A single phase 120/240VAC distribution panel will be mounted on the right side. All the equipment shall be of the same manufacturer for all distribution panels, creating a uniform and UL protected product. All panels are for surface mount type. All breaker shall be of the bolt on type. All parts shall be Siemens or equal. 1. 480VAC Main Breaker 3-Pole @225 Amps with interchangeable trip setting features (5 required, 1 uninstalled) Siemens catalog No. FXD63B225 with padlocking device Siemens catalog No. FD6PL1 2. 480VAC 200 Amp Breaker 3-Pole @ 200 Amps with interchangeable trip setting features. (13 required, 9 uninstalled with lugs) Siemens catalog No. FXD63B200 with padlocking device Siemens catalog No. FD6PL1 3. 480VAC 70 Amp Branch Breaker 3-Pole @ 70 Amps (8 required) Siemens catalog No. ED42B070 with padlocking device Siemens catalog No. ED2HPL 4. 480VAC 100Amp Branch Breaker 3-Pole @ 100 Amps (8 required) Siemens catalog No. ED43B100 with padlocking device Siemens catalog No. ED2HPL 5. 480VAC 15 Amp Branch Breaker 2-Pole @ 15 Amps (8 required) Siemens catalog No. ED42B015 with padlocking device Siemens catalog No. ED2HPL 6. 120/240VAC Distribution Panel Siemens catalog No.S3A18E4100CBS 7. 120/240VAC Main Breaker 2-Pole @ 100 Amps Siemens catalog No. ED42B100 with padlocking device Siemens catalog No. ED2HPL 8. 240VAC 20 Amp Branch Breaker 2-Pole @ 20 Amps (8 required total) Siemens catalog No.ED42B20 with padlocking device Siemens catalog No. ED2HPL 9. 240VAC 35 Amp Branch Breaker 2-Pole @ 35 Amps (4 required) Siemens catalog No.ED42B35 with padlocking device Siemens catalog No. ED2HPL 10. 240VAC 25 Amp Branch Breaker 2-Pole @25 Amps (8 required) Siemens catalog No. ED42B25 with padlocking device Siemens catalog No. ED2HPL 11. 240VAC 20 Amp Branch Breaker 2-Pole @20 Amps (12 required) Siemens catalog No. ED41B020 with padlocking device Siemens catalog No. ED2HPL 12. 240VAC 30 Amp Branch Breaker 2-Pole @30 Amps (8 required) Siemens catalog No. ED41B030 with padlocking device Siemens catalog No. ED2HPL 13. 120VAC 20 Amp Branch Breaker 1-Pole @20 Amps (8 required) Siemens catalog No. BE120 14. 240VAC 20 Amp Branch Breaker 2-Pole @20 Amps (8 required) Siemens catalog No. BE220 15. Control Power Transformers (5 required) 1000Va 240/480 primary to 120/240 secondary, K1000D31 manufactured by square D 16. Fuse Holders Gould Shawmut Part Number USCC2I 2-Pole (20 each) 17. Fuse Gould Shawmut Part Number ATQR5 5AMP (20 each) 18. Fuse Gould Shawmut Part Number ATQR10 10AMP (20 each) 19. Full voltage Reversing HP Rates Starters (9 required) Siemens part NO. SRLHL22403H with extra contacts 10 NO and 10 NC for a total of 20 For any questions on this RFQ or for salient characteristics, or a copy of the power plant distribution panels layout. FAX Albert Richard at 702 293 8050. Quote should be all inclusive for delivery to Bureau of Reclamation, Hoover Dam Warehouse, Highway 93, Boulder City, Nevada 89005. This award will be made on an all or nothing basis. The following FAR provisions and clauses apply to this acquisition: 52.212-1, Instructions to Offerors-Commercial (Jun 97). Offerors must include with their offer a completed copy of the provisions at FAR 52.212-3, Offeror Representation and Certifications-Commercial Items (Jan 97); 52.212-4, Contract Terms and Conditions-Commercial Items (May 97); Clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items (Aug 96); 52.222-26, Equal Opportunity (Apr 84); 52.222-35, Affirmative Action for Special Disabled and Vietnam Era Veterans (Apr 84); 52.222-36, Affirmative Action for Handicapped Workers (Apr 84); 52.222-37, Employment reports on special disabled Veterans and Veterans of the Vietnam Era (Jan 88). Offers must be sent in writing or faxed to the Contracting Officer listed above no later than 1630 20 August 1998.. Posted 07/30/98 (W-SN230840). (0211)

Loren Data Corp. http://www.ld.com (SYN# 0431 19980803\61-0004.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page