Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 26,1998 PSA#2167

Dahlgren Division, Naval Surface Warfare Center, 17320 Dahlgren Road, Dahlgren, VA 22448-5100

70 -- AUTO SYSTEM GC AND ACCESSORIES SOL N00178-98-Q-0083 DUE 090898 POC Wanda Chamberlain, 540-653-4404, Code SD18 or Roberta Moss 540-653-4303 Code SD18 E-MAIL: Naval Surface Warfare Center, Dahlgren Division, chamberlainwg@nswc.navy.mil. The Naval Surface Warfare Center, Dahlgren Division, Dahlgren, Virginia intends to purchase on a sole source basis one each of the following system and accessories. This is an AutoSystem XL Gas Chromatograph. The liquid autosampler must have the capability of injecting into either injection port automatically; i.e. no physical change required to switch the autosampler. The operator must be able to change the injector septa without removing the autosampler. The autosampler syringe must be designed so that is not left over a heated injection port when not in use. The operator must be able to make manual injections without having to remove the autosampler. The carrier gas pneumatics must be able to be programmed in pressure, flow or linear gas velocity. Programmable detector pneumatics must provide direct setting in mL/min, Psig, or kPa. All programmable pneumatics must compensate for variations in ambient temperature. The system must have a sleep mode to conserve carriergas by shutting off the carrier, detector & split vent gas flows. The new data system must be able to read all existing data files and methods from the existing data system. The data system must be able to control & take data from the gas chromatograph as well as take date or control the existing PE AutoSystem GC. The system must run under Windows NT. The software must be expandable to collect data from up to 8 instruments. The Nitrogen Phosphorus Detector must be of a modular design. The Flame Ionization Detector should not require makeup gas for operation with narrow bore capillary columns. Gas chromatograph must be serviced on site. All interfaces must have buffered memory to allow up to 99 chromatogram to be collected & stored even in the event of a computer failure or hard disk crash; i.e. the interface must be external of the computer. The System shall consist of one each of the following: (1) P/N N6119100 AutoSystem GC,(2) P/N N0207263 Installation AutoSystem, (3)P/N S2700049 Upgrade Software Tubochrom 4.0 to TCWS,(4) P/NS2000126 Dell OptiPlex GXA/M Workstation,(5)P/N S2701009 Turbochrom Workst IPM PE ASGC & ASLXGC, (6)P/N 65105102 IEEE-488 Cable 2M, (7) P/N N0207443 Install Turbochrom with PE Computer, (8) P/N 03328000 Installation Kit, (9) P/N N6101473 Preset Pressure Regulator, (10) P/N S2700134 Upgrade SW Turbochrom Workst SI to DI, (11) P/N N6120093 NPD Replacement Bead (5-pack), (12) P/N N9302945 Screw Top Vial Clear AutoSystem (100/pkg), (13) P/N N9303441 Screw Top Vial AutoSystem (100/pkg), (14) P/N N9303442 Septa-PTFE Red Rubber Screw Top (100/pkg), (15) P/N N9302780 Septa Waste/Wash, (16) P/N S2000121 Kit HP LaserJet, (17) P/N QSPECIAL 1 B Jazz Drive/SCSI Drive. Reference NSWC Quote N00178-98-Q-0083. Questions may be addressed to Wanda Chamberlain, phone 540-653-4404, fax number 540-653-6812 or 7016. All items shall be shipped FOB Destination to the Naval Surface Warfare Center, Attn: Receiving Officer, Bldg 125, 17320 Dahlgren Rd.,Dahlgren, VA 22448. Closing date of this synopsis/submittal of bids shall be 08 September 1998. This award is made under Simplified Acquisition procedures, Award anticipated on or before 25 September 1998. SIC code 3826 applies. Posted 08/24/98 (W-SN240935). (0236)

Loren Data Corp. http://www.ld.com (SYN# 0358 19980826\70-0008.SOL)


70 - General Purpose ADP Equipment Software, Supplies and Support Eq. Index Page