COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 1,1998 PSA#2171Fleet & Industrial Supply Center, Regional Contracts Dept, Attn: Bid
Officer/Code 210A94, 937 N. Harbor Drive, Suite 212, San Diego, CA
92132-0212 59 -- DRAWOUT BREAKERS SOL N00244-98-Q-0405 DUE 091898 POC Point of
Contact is Gwen Young, Contract Specialist/Contracting Officer at
619-532-2890; FAX 619-532-2347 WEB: Click here to learn more about FISC
San Diego and additional, http://www.sd.fisc.navy.mil. E-MAIL: Click
here to contact the Contracting Officer via,
gwen_young@sd.fisc.navy.mil. IMPORTANT NOTICE: DFARS 252.204-7004
"Required Central Contractor Registration" applies to all solicitations
issued on/after 6/1/98. Lack of registration in the CCR database will
make an offeror/quoter INELIGIBLE FOR AWARD. Please ensure compliance
with this regulation when submitting your quote. Call 1-888-227-2423 or
visit the Internet at http://ccr.edi.disa.mil for more information.
FISC San Diego is announcing its intent to issue a directed sole source
procurement to CanAm Circuit Breakers Services Inc., Brampton, Ontario,
under authority of FAR 6.302-1 for the following items. This is a
synopsis/solicitation is prepared in accordance with FAR 13. A
formal/separate written solicitation/RFQ will be issued 9/14/98, with
quotes due by 3 p.m. (PDT) 9/18/98 . Solicitation number/RFQ
N00244-98-Q-0405 applies. This solicitation document and incorporated
provisions and clauses are those in effect through Federal Acquisition
Circular 97-05 and Defense Acquisition Circular 91-13. The standard
industrial code is 3625 and the business size standard is 750
employees. This requirement is for a fixed priced contract for two (2)
lines items as follows. Line Item 0001: Supply, install and test one
(1) each 100H-3 4000 AMP, electrically operated drawout breaker
identical to the P.T.O. and SSDG air circuit breaker with CHED
40-sensor and USDM 231R relay. Line Item 0002: Supply one (1) each
50HL-3 2000 AMP, electrically operated drawout breaker. This breaker is
identical to the a) Emergency Switchboard Bus Tie 1SA and 1SB; b) Group
Control Center A and C {vital}; 450 volts Bus 1SA Group Control Center
Sta No. 3 & 4. This breaker will have 3/4x3 copper per phas and not
3/8x3. This breaker consists of CSD 20 sensor and USDM 231R relays. All
items are to be delivered to: USNS Pecos, San Diego, CA. Acceptance
shall be made at destination. PLEASE NOTE: Specifications for these
items are NOT available for release from the office issuing this
announcement. Companies interested in obtaining specifications must
contact the Military Sealift Command, Washington Navy Yard, 914 Charles
Morris Court SE, Washington, DC 20398-5540. Phone 1-888-SEALIFT,
Website http://www.msc.navy.mil. Quotes must be received no later than
3:00 PM, local time, 9/18/98. Parties interested in receiving the
formal RFQ must submit their request IN WRITING and will be accepted
via fax (619-532-2347) or via e-mail gwen_young@sd.fisc.navy.mil) ONLY.
DO NOT mail. See Numbered Note(s) 13. Posted 08/28/98 (W-SN243234).
(0240) Loren Data Corp. http://www.ld.com (SYN# 0271 19980901\59-0005.SOL)
59 - Electrical and Electronic Equipment Components Index Page
|
|