COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 16,1998 PSA#2202MEDCOM CONTRACTING CENTER, ATTN MCAA BLDG 4197, 2107 17TH STREET, FORT
SAM HOUSTON TX 78234-5015 34 -- BULK STORAGE SYSTEM FOR LIQUID NITROGEN, NITROGEN, AND CARBON
DIOXIDE SOL DADA10-99-Q-0005 DUE 111398 POC Contract Specialist Craig
Stark (210) 221-4088 (Site Code DADA10) THE U.S. ARMY MEDICAL COMMAND
(MEDCOM) CONTRACTING CENTER, FORT SAM HOUSTON, TEXAS HAS A REQUIREMENT
FOR A BULK STORAGE SYSTEM FOR LIQUID NITROGEN (LN2), NITROGEN (N2),
AND CARBON DIOXIDE (CO2) TO BE INSTALLED AT THE WALTER REED ARMY
INSTITUTE OF RESEARCH, FOREST GLEN, MARYLAND. THIS IS A COMBINED
SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH
THE FORMAT IN FAR SUBPART 12.6, AS SUPPLEMENTED WITH THE ADDITIONAL
INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE
ONLY SOLICITATION; PROPOSALS ARE BEING REQUESTED AND A WRITTEN
SOLICITATION WILL NOT BE ISSUED. THE SOLICITATION NUMBER IS
DADA10-99-Q-0005 AND IS ISSUED AS A REQUEST FOR QUOTATION (RFQ). THE
RFQ INCORPORATES PROVISIONS AND CLAUSES IN EFFECT THROUGH FEDERAL
ACQUISITION CIRCULAR 97-05. THE APPLICABLE SIC CODE IS 3443 AND THE
SMALL BUSINESS SIZE STANDARD IS 500 EMPLOYEES. THIS REQUIREMENT IS
UNRESTRICTED. THE EQUIPMENT PART NUMBERS (PN) GIVEN ARE FOR THE MVE
CRYOGENICS SYSTEM MANUFACTURED BY CRYO ASSOCIATES, ROCKVILLE, MARYLAND.
THE GOVERNMENT INTENDS TO AWARD A CONTRACT FOR THE ACQUISITION AND
INSTALLATION OF THE FOLLOWING EQUIPMENT ON A BRAND NAME OR EQUAL BASIS
(FOB DESTINATION). CONTRACT LINE ITEM (CLIN) 0001: ONE (1) EACH LIQUID
NITROGEN BULK TANK (LIQUID USE) 6000 GALLON, PN VS-6000-NC-175-WOL,
WITH ONE (1) EACH VACUUM INSULATED LIQUID WITHDRAW, ONE (1) EACH BACK
PRESSURE REGULATOR, ONE (1) EACH EXTENDED FILL, ONE (1) EACH LOW LEVEL
ALARM, ONE (1) EACH VACUUM INSULATED PIPE SYSTEM, ONE (1) EACH VJ APPS
160, ONE (1) EACH INSTALLATION PIPE SYSTEM, LN2 LIQUID USE, ONE (1)
EACH INSTALLATION BULK TANK, LN2, ONE (1) EACH PAINT COLOR OPTION, ONE
(1) EACH CONCRETE PAD AND FENCING, AND SIX (6) EACH OXYGEN ALARM, SAFE
T NET 100 W/BEACON LIGHT. CLIN 0002: ONE (1) EACH LIQUID NITROGEN BULK
TANK (GAS USE) 6000 GALLON, PN VS-6000-NC-250-WOL, WITH TWO (2) EACH
VAPORIZER, ONE (1) EACH DEFROST SWITCHING SYSTEM, TWO (2) EACH FINAL
LINE ASSEMBLY, 1" TEMP CONTROLLED, ONE (1) EACH EXTENDED FILL, ONE (1)
EACH LOW LEVEL ALARM, ONE (1) EACH AUTOMATIC DEWAR FILL STATION, AND
ONE (1) EACH INSTALLATION BULK TANK AND SYSTEM, LN2 GAS USE. CLIN 0003:
ONE (1) EACH LIQUID CO2 BULK TANK, VACUUM INSULATED, PN VC02-14, WITH
ONE (1) EACH ELECTRIC VAPORIZER, 310 LBS/HR, ONE (1) EACH PRESSURE
BUILDING SYSTEM, ONE (1) EACH EXTENDED FILL, ONE (1) EACH FINAL LINE
ASSEMBLY, ONE (1) EACH LOW LEVEL ALARM, ONE (1) EACH LOW PRESSURE
ALARM, AND ONE (1) EACH INSTALLATION BULK TANK AND SYSTEM, CO2. PROVIDE
PRICING PER PIECE OF EQUIPMENT OR INSTALLATION, NOT PER CLIN. THE
INSTALLATION WILL INCLUDE TESTING OF THE BULK STORAGE TANKS AND RELATED
ACCESSORIES. THE INSTALLATION SHALL INCLUDE A THREE (3) YEAR WARRANTY
ON ALL PARTS AND LABOR. OFFERORS INTERESTED IN SUBMITTING A PROPOSAL
SHOULD CONTACT THE PERSON LISTED BELOW TO REQUEST A COPY OF THE SALIENT
CHARACTERISTICS AND DRAWINGS. ALL PRODUCTS OFFERED OTHER THAN THAT
SPECIFICALLY REFERENCED BY BRAND NAME WILL BE REQUIRED TO MEET THE
NEEDS OF THE GOVERNMENT IN THE SAME MANNER AS THE BRAND NAME PRODUCT.
IF PROPOSING OTHER THAN THE BRAND NAME LISTED, YOU MUST SUBMIT
SPECIFICATIONS AND MANUFACTURER'S TECHNICAL DATA TO PROVE TO THE
EVALUATORS THAT THE PRODUCT YOU ARE PROPOSING IS IN FACT AN "EQUAL" TO
THE LISTED BRAND. THE COMMERCIAL ITEM FAR CLAUSES AND PROVISIONS
APPLICABLE TO THIS REQUIREMENT ARE 52.212-1, 52.212-2, 52.212-3,
52.212-4, AND 52.212-5. THE FAR CLAUSES AND PROVISIONS ARE ON THE
INTERNET AT http://www.armymedicine.army.mil/ medcom/mcaa/ FAR
PROVISION 52.212-1, INSTRUCTIONS TO OFFEROR-COMMERCIAL ITEMS (FOR THIS
SOLICITATION OFFERORS SHALL SUBMIT QUOTES ON LETTERHEAD STATIONERY TO
INCLUDE ALL INFORMATION REQUIRED BY THIS PROVISION AS WELL AS NAME OF
MANUFACTURER IF OTHER THAN BRAND NAME, MODEL NUMBER, WARRANTY
INFORMATION, DELIVERY TIME AFTER RECEIPT OF AWARD, UNIT AND EXTENDED
PRICES, AND A LISTING OF THREE (3) CUSTOMERS WITH PHONE NUMBERS THAT
HAVE PURCHASED THE MODEL BULK STORAGE SYSTEM YOU PROPOSE TO INSTALL).
FAR PROVISION 52.212-2, EVALUATION-COMMERCIAL ITEMS (AWARD OF THIS RFQ
WILL BE MADE TO THE RESPONSIBLE OFFEROR WHOSE OFFER CONFORMS TO THE
RFQ REQUIREMENTS AND WILL PROVIDE THE BEST VALUE TO THE GOVERNMENT, ALL
FACTORS CONSIDERED. FOR THIS SOLICITATION THE FACTORS TO BE USED FOR
EVALUATION OF PROPOSALS ARE: TECHNICAL CAPABILITY, PAST PERFORMANCE,
AND PRICE. TECHNICAL CAPABILITY IS MORE IMPORTANT THAN PAST PERFORMANCE
AND PRICE. THE SUCCESSFUL OFFEROR MUST BE REGISTERED IN THE CENTRAL
CONTRACTOR REGISTRATION PRIOR TO OBTAINING A GOVERNMENT CONTRACT. FOR
INFORMATION CALL 1-888-227-2423) FAR PROVISION 52.212-3, OFFEROR
REPRESENTATIONS AND CERTIFICATIONS -- COMMERCIAL ITEMS (FOR THIS
SOLICITATION OFFERORS SHALL PRINT, AND PROVIDE ALL INFORMATION REQUIRED
BY THIS PROVISION. THE COMPLETED AND SIGNED REPRESENTATIONS AND
CERTIFICATIONS SHALL BE SUBMITTED WITH OFFERORS PROPOSAL. OFFERORS THAT
FAIL TO FURNISH REQUIRED REPRESENTATIONS AND CERTIFICATIONS OR REJECT
THE TERMS AND CONDITIONS OF THE SOLICITATION, MAY BE EXCLUDED FROM
CONSIDERATION.) FAR 52.212-4, CONTRACT TERMS AND CONDITIONS-COMMERCIAL
ITEMS APPLIES TO THIS REQUIREMENT. FAR 52.212-5, CONTRACT TERMS AND
CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE
ORDERS-COMMERCIAL ITEMS (THIS CLAUSE APPLIES TO THIS SOLICITATION WITH
THE FOLLOWING ADDENDA: PARAGRAPH (B) -- THE FOLLOWING FAR CLAUSES ARE
INCORPORATED BY REFERENCE: 52.203-6 ALT 1, 52.203-10, 52.219-8,
52.222-26, 52.222-35, 52.222-36, 52.222-37, AND 52.225-3. DFARS
252.211-7003, BRAND NAME OR EQUAL, IS INCORPORATED BY REFERENCE).
QUOTES MUST BE RECEIVED NOT LATER THAN 1:00 PM ON NOVEMBER 13, 1998.
OFFERORS SHALL MAIL QUOTES TO: MEDCOM CONTRACTING CENTER, ATTN:
MCAA-C-FAC (CRAIG STARK), 2107 17TH STREET, BLDG 4197, FT SAM HOUSTON,
TX 78234-5015. QUOTES RECEIVED AFTER THE DATE AND TIME STIPULATED MAY
NOT BE ACCEPTED. FOR INFORMATION REGARDING THIS SOLICITATION CONTACT
CRAIG STARK, PHONE 210-221-4088 OR FAX 210-221-4123. Posted 10/14/98
(I-SN261874). (0287) Loren Data Corp. http://www.ld.com (SYN# 0178 19981016\34-0001.SOL)
34 - Metalworking Machinery Index Page
|
|