COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 13,1998 PSA#2221Department of the Army, Baltimore District, Corps of Engineer, 10 South
Howard Street, Room 7000, Baltimore, MD 21201-1715 C -- INDEFINITE DELIVERY-TYPE (ARCHITECTURAL LEAD) CONTRACT, FT.
GEORGE G. MEADE, MD BUT MAY BE USED THROUGHOUT THE BALTIMORE DISTRICT
SOL DACA31-98-R-0061 DUE 121498 POC Patty Hensley (410) 962-7718 1.
CONTRACT INFORMATION: A-E services are required at Ft. George G. Meade,
MD, but may be used throughout the Baltimore District. Contract will be
for a base period not to exceed one year and two option periods. The
amount of work in each contract period will not exceed $1,000,000.00.
An option period may be exercised when the contract amounts for the
base period or preceding option period has been exhausted or nearly
exhausted. Contract will be firm fixed price. The announcement is open
to all businesses regardless of size. Standard Industrial Code (SIC)
is 8712. The anticipated award is March 1999. SUBCONTRACTING PLAN
REQUIREMENTS: If the selected firm is a large business concern, a
subcontracting plan with the final fee proposal will be required,
consistent with Section 806(b) of PL 100-180, PL 95-507, and PL 99-661.
A minimum of 65% of the total planned subcontracting dollars shall be
placed with small business concerns. At least 15% of the total planned
subcontracting dollars shall be placed with small disadvantaged
businesses (SDB), including Historically Black Colleges and
Universities or Minority Institutions, and 8% with Women Owned Small
Businesses (WOSB). The plan is not required with this submittal. 2.
PROJECT INFORMATION: Preparation of reports, studies, design criteria,
design and other general architect-engineer services for alterations,
renovation, maintenance and repair, and minor architectural. Work may
also include renovation of administrative building, medical
facilities, troop living facilities (barracks), and utilities systems.
3. SELECTION CRITERIA: See Note 24 for general A-E selection process.
The selected firm shall have the capability to provide architectural,
structural, mechanical, electrical, and environmental engineering;
topographic surveying and cost estimating. Staff shall include
registered or certified personnel, including certified industrial
hygienist. Firm shall have experience in storm water management,
wetlands hydrology, sediment and erosion control, and National
Pollutant Discharge Elimination System (NPDES) permitting (includes
obtaining all necessary state permits, etc.); HAZMAT in the form of
asbestos containing materials (ACM), lead paint, etc., may be
encountered. Firms must demonstrate capability to conduct appropriate
characterization assessment, remedial planning and design to identify
and formulate corrective measures for these HAZMAT's. Firms must
demonstrate capability of responding to multiple task orders
concurrently. The products (deliverables) are not required to be
performed using a specific CADD system; however, the selected firm
shall be required to provide any digitizing and/or translation services
necessary to deliver the final design product(s) in AutoCAD Rel. 14 on
3 1/2 inch HD diskettes formatted for 1.44 MB. Specifications will be
prepared using SPECSINTACT. Cost estimates will be prepared using the
MicroComputer Aided Cost Estimating System (MCACES). 4. SUBMISSION
REQUIREMENTS: See Note 24 for general submission requirements.
Interested firmshaving the capabilities to perform this work must
submit one copy of SF 255. A SF 255 must be submitted for prime and
joint ventures and a SF 254 must be submitted for prime, joint
ventures, and consultants, to the above address, not later than the
close of business on December 14, 1998. Include ACASS number on the SF
255, Block 3b. For ACASS information, call (503) 808-4591. The SF 255
and SF 254 shall clearly indicate the staffing of the office indicated
to do the work. Street address: City Crescent Building, ATTN: Patty
Hensley, Room 7000, 10 South Howard Street, Baltimore, MD 21201.
Solicitation packages are provided only to the selected firm after
selection approval. Results of selection will be mailed to non-selected
firms approximately 70 days after closing of this announcement.
Contracting questions can be directed to patty.hensley@nab02.usace.
army.mil. Technical questions can be directed to Ms. Faith McNamee,
(301) 677-9354. "In order to comply with the Debt Collection
Improvement Act of 1996, all contractors must be registered in the
Central Contractor Registration (CCR) to be considered for an award of
a Federal contract. The initial registration date expired 31 May 1998.
For information regarding future registration, contact: (1) CCR Web
site at http://www.acq.osd.mil/ec.; (2) Dial up modem at (614) 692-6788
(User ID: ccrpub; Password: pub2ccri); (3) through any DoD Certified
Value Added Network. To review the database the web site is http://www.
fedecnavigator.disa.mil. Additionally, a paper form for registration
may be obtained from the DoD Electronic Commerce Information Center at
1-800-334-3414." Solicitation packages are not provided on this
project. This is not a request for proposal. Posted 11/10/98
(W-SN270233). (0314) Loren Data Corp. http://www.ld.com (SYN# 0033 19981113\C-0011.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|