COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 16,1998 PSA#2222Commander, U.S. Army Aviation and Missile Command, Acquisition Center,
Research Development and Engineering Center, Redstone Arsenal, AL
35898-5000 66 -- SIX DEGREE OF FREEDOM SERVO-HYDRAULIC EXCITER SYSTEM DUE 112498
POC (RDPC)Contract Specialist, Melinda E. Dodson, AMSAM-AC-RD-AX,
256-842-7403, Contracting Officer, Richard Williams, 256-876-5207 The
Dynamic Test Branch of the Redstone Technical Test Center, USA TECOM is
seeking information from industry regarding capabilities to provide a
commercial six degree-of-freedom (6-dof) servo-hydraulic exciter
system. The system will be used as a general-purpose platform for
performing 6-dof vibration testing on an array of military hardware.
The system will be used in conjunction with an acoustic chamber;
therefore, physical dimensions will be a major factor in the selection
process. The system will be powered by an existing pressure
compensated hydraulic power supply, which is rated at 100 GPM
continuous flow at 3000 PSI (Mobil DTE-26 oil). The following
paragraphs outline the "basic" system requirements. A specification
will be developed subsequent to this source synopsis. All hardware and
software required to meet the requirements outlined below must be
commercially available. External dimensions shall have a nominal
footprint of 48"(L) x 48"(W) x 64"(H) with a moving element with
nominal dimensions of 32"(L) x 32"(W) x 32"(H). The moving element
shall be configured such that any of the three mutually orthogonal 32"
x 32" surfaces may be used as general purpose mounting surface. Each
surface shall have a four-inch grid of threaded inserts. The exciters
shall be integrated such that the system is capable of simultaneously
producing motion in each of 6-dof (vertical, lateral, longitudinal,
roll, pitch, and yaw). Each actuator shall be configured with minimum
linear and angular motion capabilities of 2 inches DA and 6.5 degrees
respectively. The force rating of each exciter shall be no less than 14
thousand pounds force (klbf). The moving portion of the exciter system
shall have a first mode of no less than 300 Hz and a useable frequency
bandwidth of DC -- 250 Hz. All power amplifiers, servos, and display
units required to stabilize the system shall be included and configured
by the supplier. A control system capable of performing 6-dof
motion-replication and 6-dof spectrum/coherence referenced control
shall also be included. The bandwidth of the control system shall be
user selectable with a bandwidth of not less than 2000 Hz. The control
system shall be configured with a graphical user interface for
efficient user entry of reference profiles and user selectable
parameters such as frequency resolution, test times, etc. The control
system shall be configured with sufficient DAC channels to control each
of the individual exciters (6 minimum) and 18 ADC feedback channels
configurable as either control, limit, or measurement channels.
Potential offerors should also provide information to the following: 1)
Size and status of your company. 2) Catalog or printed information,
including specifications, of commercially available product capable of
meeting requirements. 3) Commercial pricing and cost of integration.
4) Approximate delivery time. The information contained herein is for
planning purposes only and does not constitute a request for proposal.
Solicitation documents are not available. Technical point of contact
is Sharon Mueller-Myers, 256/876-5642. Proprietary data will be
protected when properly marked. Interested offerors should respond by
submitting answers to the questions and company information to the
contracting officer. Responses are requested no later than 24 November
1998. Please provide information to U.S. Army Aviation and Missile
Command, AMSAM-AC-RD-AX/MELINDA E. DODSON, Redstone Arsenal, Alabama
35898-5275. Posted 11/09/98 (W-SN269634). (0313) Loren Data Corp. http://www.ld.com (SYN# 0450 19981116\66-0015.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|