Navy Public Works Center, 2730 McKean St, Ste 1, San Diego, CA 92136-5294

61 -- MEDIUM VOLTAGE CABLE SOL N63387-99-Q-P014 DUE 120298 POC Cynthis Horriatt, Purchasing Agent, (619)556-9051, FAX: (619)556-7775 3600 Feet Medium Voltage cable. Size 4/0. Medium voltage cable shall be single conductor, ehtylene propylene rubber (EPR) insulated; and shielded power cable shall be rated at 15kv, 133 percent insulation level. The cable shall be capable of operating continuously in both wet and dry locations at 90 degree C for normal operation, 130 degree C under emergency operating conditions and 250 degree C under short circuit conditions. The conductor shield, insulation and insulation shield shall be applied continuously in the same pass by an in-line triple extrusion process. The cable shall be insulated, jacketed, and tested in accordance with AEIC CS6, in the same plant by the same manufacturer. Certified AEIC qualification data shall be required prior to order placement. Cable ends must be sealed. Conductor shall be class B stranded annealed copper per part 2 of ICEA S-68-516. Conductor shield shall be extruded black, semi-conducting thermosetting compound thermally and chemically compatible with the conductor and the insulation applied over the conductor. Conductor shield shall be uniformly and firmly bonded to the overlying insulation and be free stripping from the conductor. The thickness of the conductor shield shall conform to AEIC CS6. Insulation shall be EPR conforming to AEIC CS6 and shall have a minimum average thickness of 220 mils. The ethylene content of the EP compound shall not exceed 72 percent by weight. Insulation shield shall be extruded black, semi-conducting thermosetting compound thermally and chemically compatible with the insulation and the copper tape applied directly over the insulation. The insulation shield shall be free stripping, leaving no conductor particles or other residual on the insulation surface. The thickness of the insulation shield shall conform to AEIC CS6. Copper tape shield shall have a thickness of 5 mils, helicaly applied over the insulation shield with a minimum of 12 percent overlap. Jacket shall be chlorosulfinated polyethylene (HYPOLON) with a minimum thickness of 80 mils. Cable to be supplied on three reels of 1200 feet each. 3600 FEET Medium voltage cable. Size 350 MCM. Medium voltage cable shall be single conductor, ehtylene propylene rubber (EPR) insulated; and shielded power cable shall be rated at 15kv, 133 percent insulation level. The cable shall be capable of operating continuously in both wet and dry locations at 90 degree C for normal operation, 130 degree C under emergency operating conditions and 250 degree C under short circuit conditions. The conductor shield, insulation and insulation shield shall be applied continuously in the same pass by an in-line triple extrusion process. The cable shall be insulated, jacketed, and tested in accordance with AEIC CS6, in the same plant by the same manufacturer. Certified AEIC qualification data shall be required prior to order placement. Cable ends must be sealed. Conductor shall be class B stranded annealed copper per part 2 of ICEA S-68-516. Conductor shield shall be extruded black, semi-conducting thermosetting compound thermally and chemically compatible with the conductor and the insulation applied over the conductor. Conductor shield shall be uniformly and firmly bonded to the overlying insulation and be free stripping from the conductor. The thickness of the conductor shield shall conform to AEIC CS6. Insulation shall be EPR conforming to AEIC CS6 and shall have a minimum average thickness of 220 mils. The ethylene content of the EP compound shall not exceed 72 percent by weight. Insulation shield shall be extruded black, semi-conducting thermosetting compound thermally and chemically compatible with the insulation and the copper tape applied directly over the insulation. The insulation shield shall be free stripping, leaving no conductor particles or other residual on the insulation surface. The thickness of the insulation shield shall conform to AEIC CS6. Copper tape shield shall have a thickness of 5 mils, helicaly applied over the insulation shield with a minimum of 12 percent overlap. Jacket shall be chlorosulfinated polyethylene (HYPOLON) with a minimum thickness of 80 mils. Cable to be supplied on three reels of 1200 feet each. Price to include shipping to 32nd Street Naval Station in San Diego, CA. This is a combination synopsis/RFQ; no solicitations will be sent out. Acceptance of bids for this announcement will close on 2 December 1998 at 4:00 PM PST. FAX or mail quotes will be accepted. Mail quotes will not be accepted. See Numbered Note(s): 1. Posted 11/16/98 (W-SN271820). (0320)

Loren Data Corp. http://www.ld.com (SYN# 0255 19981118\61-0002.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page