Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 8,1998 PSA#2237

DHHS/FDA/NCTR, Contracts Branch, HFT 322, 3900 NCTR Road, Jefferson, AR 72079-9502

66 -- HAMILTON THORNE RESEARCH NO. 790500 MULTI-SPECIES SPERM ANALYSIS SYSTEM SOL R-5007-00-9-00 DUE 012199 POC Contact Karen Moore, Contract Administrator, 870/543-7479/Priscella Thomas Sullivan, Contracting Officer, 870/543-7271 66-It is the Government's intention to negotiate on a Sole Source basis with Hamilton Thorne Research for a 790500 Multi-Species Sperm Analysis System which includes; 1 EA. Multi Species Sperm Analysis System, 1 EA. Oval Head Sperm Motility Software, 1 EA. Metrix Morphology Software, 1 EA. Rat Metrix Morphology Software, and 1 EA. 40x Fluorescent Objective. The system must have the following minimum specifications: Specimen Holder; Temperature Control must range from Room Temperature to 45 deg. C, Temperature stepsize of 0.1 deg.C, Temperature stability of 0.5 deg. C, Programmable Stage Position. Specimen Chambers; Cannula with depth of 100 micron and >30 fields, slide with 20 and 50 microns and 30 fields, programmable user definition. Internal Optical System; Imaging device, high resolution CCD array, objective minimum of 4x, 10x, 10 UV, image type, dark field, bright field, phase contrast, negative and positive, image output, NTSC, RS-170 60Hz. Illumination System; light source, stroboscopic, photometer with an on screen scale, exposure to include source on only during acquisition and focus, pulse 1.3 millisecond, intensity, computer controlled, monitor, digitized image with 640 x 480 pixels, spectra-indent fluorescent light source, illumination, epifluorescent, source strobe Xenon, pulse, 5-8 millisecond, intensity, computer controlled, filter, double bandpass, 450 mm and 660 mm. Data Acquisition, frame rate, 60, 30, 15, 7.5 Hz, frames from 5 minimum and 100 maximum, system must have 1-20 fileds, designation, automatic or selected. Analyzing System; Input signal, NTSC, RS-170, control from a mouse and keyboard, analysis time, 30 seconds for 200 cells, software to measure count (total, motile, progressive, % motile, % progressive), concentrations (total, motile, progressive (m/mL), distributions (LIN, STR, VCL, VSL, VAP, ALH, BCF, head size-elongation), and total sperm count from homogenized samples. System has a Quality Check Playback and Quality Control Graphs, Analysis Sets to include two preset and five user defined. Video Capability; Able to analyze both 50 Hz (PAL) and 60 Hz (NTSC). Standard Toxicology Software; Includ software that does "counts", "concentrations", "mean values", "distributions", and "Graphics". Data Output; Internal hard drive, floppy disk drive and an external monitor. Internal Computer System; This system must have 200 MHz Pentium CPU, 32 MB RAM, 2 serial and 1 parallel ports, 1.44 MB 3.5" high density floppy drive, 2.5 gigabyte hard drive, 17" Super VGA color monitor and must be year 2000 compliant. This system must also come with the following; Spectra Ident automated sperm concentration analysis of homogenized cauda samples using DNA specific fluorescent stain and integrated fluorescent illumination. Sort function which determines fraction of cells within user specified limits on VCL, VSL, LIN, STR, ALH, BCF, Head size and Head Shape. Track editing, which allows you to view and store detailed data for individual sperm tracks (used for validation procedures). HDATA ASCII exportwhich allows the transfer of summary data and/or individual track to ASCII compatible spreadsheets for database programs. Clinical filing which provides the ability to design three one page reports and store analysis reports to file. INFORMATION RECEIVED IN RESPONSE TO THIS NOTICE WILL BE USED FOR DETERMINING WHETHER TO CONDUCT A COMPETITIVE PROCUREMENT. WRITTEN SUBMISSIONS OF INTEREST SHOULD BE SPECIFIC IN IDENTIFYING THE PROSPECTIVE OFFEROR'S CAPABILITY TO PERFORM. See numbered note 22***** Posted 12/04/98 (W-SN277356). (0338)

Loren Data Corp. http://www.ld.com (SYN# 0293 19981208\66-0017.SOL)


66 - Instruments and Laboratory Equipment Index Page