COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 16,1998 PSA#2243US Army Armament And Chemical Acquisition And Logistics Activity
(ACALA) Attn: AMSTA-AC-PCC Rock Island, IL 61299-7630 99 -- MISCELLANEOUS POC Linda Hultman, 782-3392 DESC: The U.S. Army,
TACOM-ACALA, Rock Island, IL is seeking sources for LP Compressors. The
compressors must provide divers with breathable air and effectively
support the Recompression Chamber, Diving Equipment Set Deep Sea
(DES-DS), Diving Equipment Set-Lightweight, and the Underwater
Construction set (USC). The requirements of the Compressors are as
follows: 1. Provides 44-50 SCFM at 300 PSI. 2. Compressor cycles
between 250-300 PSIG. 3. 60-gallon stainless steel volume tank with a
300-315 PSI working pressure. 4. Filter rack attached to volume tank
frame; all drain valves are manually operated, including filters. 5.
Air distribution manifold equipped with 3 "outlet valves"/17thread
female deepsea fitting with rotating nut. 6. Air meets purity standards
outlined in FM 20-11-1 diving manual as follows: Oxygen % by volume 20
22%; carbon Dioxide by volume 1000 ppm (max); Carbon Monoxide by
volume 20 ppm (max); Total Hydro carbons (as CH4) by volume 25 ppm
(max); Oil Mist, Particulates by weight/volume5mg/m3 (max), for divers
breathing air. 7. Two 100' and two 50' deepsea hoses will be provided
with each compressor and stored in their own container box. 8.
Air-cooled diesel engine that runs JP8 as its primary fuel. 9. Ambient
temperature operating range from 120F to 10 F. 10. Minimum 4-hour fuel
supply. 11. Engine equipped to start with hand crank and air start. 12.
All components except air hoses packaged in a single frame that can be
lifted by forklift and hoist. Must also have tie down securing points
to allow transport by air, sea or rail. 13. Frame is equipped with a
retractable hydraulic wheel system so compressor can be pushed around
by hand on hard surfaces. 14. Total package must weigh less than 2000
lbs. 15. Minimum one year warranty on complete package, starting from
delivery date. 16. Compressor system must be able to operate 300 hours
without failure. Anything correctable within 10 minutes with standard
tools will not be considered a failure. 17. Contractor will provide
technical manuals which detail safe and efficient operations and
maintenance procedures. 18. Contractor will supply training guides and
conduct new equipment training for each gaining unit. Training will
cover operating procedures and operator level maintenance. It should be
noted that this is not a Request for Proposal; the purpose of the
sources sought notice is to seek commercial sources that will meet the
U.S. Government's requirement. Interested parties may submit written
information to ACALA, AMSTA-AR-EST-P, Richard Koenig, Rock Island, IL
61299-7630. Posted 12/14/98 (W-SN280091). (0348) Loren Data Corp. http://www.ld.com (SYN# 0289 19981216\99-0006.SOL)
99 - Miscellaneous Index Page
|
|