Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 18,1998 PSA#2245

Huntington District Corps of Engineers, 502 Eighth Street, Huntington, WV 25701-2070

43 -- STORMWATER PUMPS FOR THE WEST COLUMBUS, OHIO, IIID PROJECT POC Ronald F. Vest, CONTRACT SPECIALIST (304)529-5040, John B. Roberts, CONTRACTING OFFICER This is a Sources Sought Announcement is essentially for firms having the capability to provide stormwater pumps for the West Columbus, Ohio, IIID project. The 4 pumps which shall also include (1ea 20,000 GPM @ approx. 33 feet TDH and 3ea 40,000 GPM @ approx. 33 feet TDH) we also want to include purchase of the Formed Suction Intakes (FSI), the pump tubes, elbows, and flap valves for each of the four pumps. Construction work at West Columbus will not start until sometime in 2000. However, the Government is anticipating delivering of the pumps by September 1,1999. Pumps are to be submersible electric type. The vertical axial or mixed flow pumps shall have direct coupled electric motors that operate from 2,400 VAC, 3 phase power. The pumps will be set in vertical pipes supported from operating floor above. Discharge will be out the side of the pipe or tube through a horizontal wall pipe and flap valve into the discharge chamber. Intakes to the pumps will be mated to Formed Suction Inlets (FSI). The design of the FSIs will be in accordance with Corps standards where all dimensions relate to pump inlet diameter. Critical elevations are stated below: Top of Discharge Chamber 718 Pump Station Operating Floor 703 Ground Elevation 702 Centerline Discharge From Tube 698 Approx. Pump Station Floor (Sump) 669 Note these values are approximate and subject to change as our design evolves. Purchase, testing and receipt of these items within the next 9 months is ambitious and will require persistent attention. In order to quickly produce the specifications, advertise and award can proceed, detailed information is being solicited from typical vendors. The intent is to make the specifications unrestrictive and having detailed input from vendors should help. GIVEN Design Requirement for Pump -- 20,000 GPM @ 33 feet TDH (1 each required) address the following: What is your suggested pump model? What is the motor horsepower and available voltage? What is it's deliver (in GPM) at 33 feet of head? What is it's delivery (in GPM) at 13 feet of head? What is it's delivery (in GPM) at 38 feet of head? What are the pump NPSHRs @ of these three points? Also furnish hard copy (not fax) of pump curves: Are there head losses in your pumps that are not accounted for on your pump curves? Quantify those losses in feet of head. Is the pump American made in accordance with the Buy American Act? What would be the time to manufacture? GIVEN Design Requirement for Pump -- 40,000 GPM @ 32 TDH (3 each required) What is your suggested pump model? What is the motor horsepower and available voltage? What is it's deliver (in GPM) at 33 feet of head? What is it's delivery (in GPM) at 13 feet of head? What is it's delivery (in GPM) at 38 feet of head? What are the pump NPSHRs @ of these three points? Also furnish hard copy (not fax) of pump curves: Are there head losses in your pumps that are not accounted for on your pump curves? Quantify those losses in feet of head. Is the pump American made in accordance with the Buy American Act? What would be the time to manufacture? Provide drawing details of your pump(s) tube at the top, bottom and where the horizontal discharge occurs. We need to see how your pump is mounted in the tube and how it might be connected to an FSI. Details on 8 1/2 x 11 will be accepted. A Preliminary Sketch of the pump location will be provided upon request. Fax your request to Ronald F. Vest at (304)529-5281. Questions can be addressed by Fax also. Per this request, provide all drawings, documents, literature, or other pertinent information that describes the above request and mail hard copy to the Huntington District, Corps of Engineers, 502 8th Street, Huntington, West Virginia 25701-2070, Attn: Ronald F. Vest, Contracting Division. This is not a solicitation for bids or quotes. Posted 12/16/98 (W-SN280980). (0350)

Loren Data Corp. http://www.ld.com (SYN# 0203 19981218\43-0004.SOL)


43 - Pumps and Compressors Index Page