|
COMMERCE BUSINESS DAILY ISSUE OF JANUARY 7,1999 PSA#2257U.S. Coast Guard Engineering Logistics Center, 2401 Hawkins Point Road,
Mail Stop #26, Baltimore, MD 21226-5000 35 -- REQUIREMENTS TYPE CONTRACT FOR THE PROCURMENT OF CG-P6 PORTABLE
DEWATERING AND ASSISTANCE PUMP UNITS FOR A BASE AND OPTIONS TO RENEW
FOR FOUR ADDITIONAL YEARS SOL DTCG40-99-R-70014 DUE 041999 POC Point of
Contact -- Contact Catherine Baskin, Contract Specialist (410)
762-6483. James McGuirk, Contracting Officer (410) 762-6486. Please fax
request to Telefax Number (410) 762-6008 35 -- 1) ACN 4320-01-F99-0342,
Pump, Dewatering, estimated quantity 390 each the base year and a
quantity of 90 for each option year. Pump units are to be manufactured
in accordance with Specification P-503-0330 dated 10/31/98, which is
available now upon request to all interest parties. Accessories and
Additional Accessories as stated in Specification P-503-0330 shall also
be provided with Pump unit as follows: 1) ACN 4320-01-F99-0442, Suction
hose and Strainer (minimum length of 15 feet), estimated quantity 390
each for base year and 90 for each option year, 2) ACN
4320-01-F99-0444, Discharge Hose (20-foot length for dewatering),
estimated quantity 390 each for base year and 90 for each option year,
3) ACN 4320-01-F99-0446, Removable fuel tank(s) with tank level gauge
and fuel, estimated quantity 390 each for base year and 90 for each
option year, 4) ACN 4320-01-F99-0447, Secondary starting method
apparatus, estimated quantity 390 each for base year and 90 for each
option year, 5) NSN 6230-00-299-3035, Flashlight (Explosion proof),
estimated quantity 390 each for base year and 90 for each option year,
6) ACN 4320-01-F99-0445, Instruction Card, estimated quantity 390 each
for base year and 90 for each option year, 7) ACN 4320-01-F99-0443,
Suction hose and Strainer (minimum length of 25 feet), estimated
quanity 390 each for base year and 90 for each option year, 8) ACN
4320-01-F99-0446, Extra Fuel Tank, estimated quantity 390 each for base
year and 90 for each option year. 9) ACN 4320-01-F99-0448, Suction
Inlet Adapter, estimated quantity 390 each for base year and 90 for
each option year. The solicitaiton will be on the street for 60 f days
to allow for testing and submission of proposals. An application for
Scheduling of Testing and Shipment of Containers must be requested at
least 2 weeks prior to testing. All testing will be done in accordance
with Specification P-503-0330. delivery for the CG-P6 Pump untis shall
be F.O.B. Destination, 60/90 days ARO to USCG Engineering Logistics
Center, Warehouse Annex, 6751 Alexandria Bell Drive, Columbia, MD
21046-2102. All responsible and responsive sources are invited to
express their interest and ability to provide the described item, via
fax and in writing. Also, responsive and responsible sources may submit
a proposal which will be considered by this agency. Attention:
Minority, Women-Owned and Disadvantaged Business Enterprises (DBEs)!
The Department of Transportation (DOT), Short-Term Lending Program
(STLP) offers working capital financing in the form of lines of credit
to fiance accounts receivable for transportation related contracts,
call (800) 532-1169. Internet address: http://osdbuweb.dot.gov. See
Note 26 (AC0105006-01) Posted 01/05/99 (I-SN285325). (0005) Loren Data Corp. http://www.ld.com (SYN# 0175 19990107\35-0001.SOL)
35 - Service and Trade Equipment Index Page
|
|