Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JANUARY 19,1999 PSA#2264

Fleet and Industrial Supply Center, Puget Sound, Bldg 467 W Street, Code 200 Bid Desk, Bremerton, WA 98314-0051

66 -- LOAD BANKS REACTIVE SOL N00406-99-R-5078 DUE 030199 POC Maureen Renville (360)476-7174 E-MAIL: Contracting Officer, maureen_renville@puget.fisc.navy.mil. Load Banks Reactive, 1 EACH 1000KW. Transportable, electical load bank designed and costructed for post overhaul testing of sundry shipboard electrical machinery. Equipment shall perform continuously under any load condition including full rated load. Overall size and weight shall not exceed 8 ft wide, 16 ft long and 8.5 ft high maximum; 18,000 lbs max. Load bank shall provide the minimum, continuous duty, ungounded load capacities: 1000KW -- 460V, 3 phase 3 wire; 500 KW, 460V, 1 phase 2 wire 60 Hertz; 284 KW, 240V, 3 phase 3 wire; 500 KW, 460V, 1 phase 2 wire 60 Hertz; 71 KW, 120V, 3 phase 3 wire 60 Hertz; 213 KW 120V, 3 phase 3 wire 60 Hertz; 925 KW, 250V Direct Current, 2 wire; 617 KW, 500V, Direct Current, 2 wire. Load Banks Reactive, 1 EACH 500KW. Transportable, electical load bank designed and constructed for post overhaul testing of sundry shipboard electrical machinery. Equipment shall perform continuously under any load condition including full rated load. Overall size and weight shall not exceed 8 ft wide, 16 ft long and 8.5 ft high maximum; 18,000 lbs max. Load bank shall provide the minimum, continuous duty, ungounded load capacities: 500 KW, 460V 3 phase 3 wire, 60 Hertz; 426 KW, 120V, 3 phase 3 wire 60 Hertz; 35 KW, 120V, 3 phase 3 wire 60 Hertz; 106KW, 120V, 1 phase, 2 wire 60 Hertz; 460V 250 direct current, 2 wire; 398 KW, 500V direct current, 2 wire. For both load banks, design and construction shall be considerate of operating and storing the equipment, without added protection, under any combination of the following ambient conditions without loss of capacity: Elev 50 ft below to 100 ft above mean seal level; temp 32 to 104 degrees F; Relative humidity 0 to 100%; wind 0 to 100 MPH; unusual service conditions: salt water spray, direct exposure to sunlight, contaminated industrial environment including dust, fumes, smoke, blast grit and inclement weather wind driven rain and snow. This is a 100%_Small Business Set-Aside. Required delivery is 180 days after effective date of contract. Inspection at source, acceptance at destination. FOB Puget Sound Naval Shipyard, Bremerton WA 98314-5000. For Foreign Military Sales. NOTES: _1, 9, 12, 26__ apply. All responsible sources may submit offer/bid which shall be considered by FISC Puget Sound. Telephone requests will not be honore. Fax requests will be accepted at 360-476-2931. Posted 01/14/99 (W-SN288103). (0014)

Loren Data Corp. http://www.ld.com (SYN# 0242 19990119\66-0004.SOL)


66 - Instruments and Laboratory Equipment Index Page