COMMERCE BUSINESS DAILY ISSUE OF JANUARY 22,1999 PSA#2267Commercial Acquisition Department, Bldg 11, Naval Undersea Warfare
Center Division, Newport, Code 59, Simonpietri Dr., Newport, RI
02841-1708 70 -- MODIFICATION TO PERFORMANCE SPECIFICATION FOR HIGH SPEED WINDOWS
NT BASED ANALOG RECORD AND PLAYBACK SYSTEM SOL N66604-99-Q-0949 DUE
012699 POC J. Clermont, Contract Negotiator at (401) 832-1460; J.
Masterson, Contracting Officer at (401) 832-1585; FAX (401) 832-4820.
WEB: Naval Undersea Warfare Center Division, Newport,
http://www.npt.nuwc.navy.mil/contract/. E-MAIL: Jeannie Clermont,
Contract Negotiator, clermontjm@npt.nuwc.navy.mil. This modification is
to amend the performance specification. This was originally published
on 8 December 1998 in the Commerce Business Daily. Paragraphs 1 through
4 of the Performance Specification are hereby modified. 1. General: The
requirement is for a high speed Windows NT based analog recording and
playback system (data recorder) with a minimum of 8 analog input
channels with each channel being recorded at 16 bits and with a maximum
bandwidth of up to 90 kHz (kilohertz) per channel. 2. The system shall
come with programmable gain amplifiers, simultaneous sampling and
programmable anti-aliasing filters, and a minimum of 18 gigabytes of
storage disk. The system shall record data from the eight channels
gap-free onto the storage disk for up to the time required to fill the
entire disk. 3. The analog input channels shall be sampled at 16 bit
resolution with conversion rates sufficient to achieve 90 kHz analog
bandwidth per channel. Sampling shall be simultaneous on the input
channels. The sampling rates shall be software selectable over the
range of sampling frequencies. It is understood that at the lower
sampling frequencies the bandwidth of the input channels will decrease
in accordance with the Nyquist Sampling Theorem. To achieve the 90 kHz
bandwidth on each channel, the sampling must be 180 kHz or higher. 4.
The input voltage range shall be software selectable in ranges between
+/- 40 volts down to +/- 1 volt with an amplifier frequency response
that is flat to 90 kHz. Our department no longer issues solicitations
or amendments in paper form. Instead, they may be accessed at our web
site http://www.npt.nuwc.navy.mil/contracts. We also provide electronic
access in our Bid Room. Estimated RFP release date: 1/19/99; SIC Code:
3825. Posted 01/20/99 (W-SN289463). (0020) Loren Data Corp. http://www.ld.com (SYN# 0278 19990122\70-0002.SOL)