COMMERCE BUSINESS DAILY ISSUE OF JANUARY 27,1999 PSA#2270Commanding Officer, Southern Division,Naval Facilities Engineering
Command, 2155 Eagle Drive, P. O. Box 190010, North Charleston, SC
29419-9010 Z -- UPGRADE TANKS, FILLSTANDS & PIPING, NAS, KEY WEST, FL SOL
N62467-98-B-0964 DUE 030999 POC POC: David Pilarski, FAX Number (843)
820-5853 MODIFIED SOLICITATION NOTICE: THE COST FOR EACH SET OF PLANS
AND SPECIFICATIONS IS $50. THE POINT OF CONTACT IS PAULA BROOKS AT
843/743-4040, Ext, 24. THIS CHARGE IS NON-REFUNDABLE. To obtain plans
and specifications you may send company check payable to US Treasury
and send to the DEFENSE AUTOMATED PRINTING SERVICE, ATTN: PAULA BROOKS,
P O BOX 71359, CHARLESTON, SC 29405 OR FOR DIRECT OR EXPRESS MAIL
DELIVERY, ADDRESS YOUR REQUEST TO SUITE B 2825 AVENUE D. NORTH
CHARLESTON, SC 29405-1819. Please indicate if you are a Prime
Contractor, Subcontractor, Supplier, ETC. Please also include (1) A
Point of Contract, (2) A Telephone Number, and (3) a FAX Number. If
problems arise concerning your request, call PAULA BROOKS at
843/743-4040, Ext. 18. To obtain a plan holders list FAX your request
to 843/743-3027. Plan Holders List will be mailed. Plan Holders List
can be obtained from the Internet at http://www.chas.sebt.daps.mil. For
inquiries about RECEIPT OF PROPOSAL, NUMBER OF AMENDMENTS ISSUED,
CONTACT SUSANCLARK at (843) 820-5775. The work includes the following,
identified as Part A and Part B. The work includes a bid option,
exercised at the Government's discretion. Part A-Upgrade Boca Chica
Tank Farm ASTS. Work includes the provision of tank repairs and
modifications to one (1) 5,200 barrel, two- (2) 5,600 barrel and one
(1) 7,000 barrel, existing aboveground steel storage tanks. Tank
repairs include new cone down steel floors with leak detection and
underfloor liners, underfloor cathodic protection, shell insert plates
and nozzles, new tank internal piping, concrete ringwalls, and other
miscellaneous tank repairs. The work also includes providing new above
grade fuel piping, a truck offload facility, and abandoning the
existing below grade fuel piping. PART B Upgrade Fillstand and
underground Piping. Work includes providing a leak detection system for
the 2 fuel lines from the Boca Chica Tank Farm to the truck fillstand
(A-935); a truck refueler parking slab; modifications to the seven (7)
concrete valve pits for the two fuel lines; a drainage trench,
security lighting and new filter separators at truck fillstand A935; a
new level detection system at the truck fillstand and a new dedicated
level detection system signal line from truck fillstand A935 to the
Boca Chica Tank Farm. BID OPTION Work includes the provision of a
refueler truck parking slab, an oil/water separator, an infiltration
pond, and power to the security lights and truck fillstand from the
existing building A902. Contractor must show experience/competency in
the performance of upgrading existing above ground vertical petroleum
storage tanks to include new cone down steel floor with secondary
containment (Geomembrance Liner), underfloor leak detection and
cathodic protection in accordance with API 650, API 653 and Florida
Regulations. Contractor must show experience/competency in performing
underground pipeline leak detection which has been approved by the
state of Florida (FDEP). Estimated cost of project is $1,000,000 to
$5,000,000. Estimated duration of the contract is 460 calendar days for
completion. The SIC Code for this project is 1799. Size Standard is
$7,000,000.00. THIS SOLICITATION IS ADVERTISED AS UNRESTRICTED.****
Posted 01/25/99 (W-SN290909). (0025) Loren Data Corp. http://www.ld.com (SYN# 0118 19990127\Z-0006.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|