Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JANUARY 29,1999 PSA#2272

USPFO For Wisconsin, F/B/O Volk Field CRTC, Attn: Contracting Office, 8 Madison Blvd., Camp Douglas, WI 54618-5002

54 -- FUEL STORAGE TANK, 25,000 GALLON JP-8 FUEL STORAGE TANK SOL DAHA47-99-Q-0307 DUE 022599 POC MSgt Neal Hause at (608)427-1235 Contracting Officer, SMSgt Kelly Clark at (608)427-1234 Contracting Officer. E-MAIL: click here to contact the point of contact via e-mail, nhause@wivok.ang.af.mil. Numbered Notes:1, This ia a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation;proposals are being requested and a written solicitation will not be issued. DAHA47-99-Q-307 Request For Quotation. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 97-09. The request is set-aside for Small Business, Standard Industrial Classification Code: 3499, Size Standard 500. Item 0001, Quantity: 2,Unit of Issue: Each, Tank, Fuel Storage, used to store aircraft fuel, Size: 25,000 gallon(minimum), Fuel to be stored: JP-8, Size of containment area: 76 feet in length x 73 feet in width (divided by a 12" wall), Requirements:1 Each(per tank) 4" male camlock fitting with dust covers, fitting to be centered on tank 6" from bottom of tank on one end, 1 Each 4" female cam lock fitting with dust plugs, fitting to be centered on tank 6" from bottom of tank(opposite end of tank then the male fitting), tank will be mounted on skids to leave tank 24" off the ground, interior walls of the tank shall be non-ferrous material and epoxy coated, tank is to be sloped bellied or have a center sump to drain water, tank is to have a 1" pipe from the bottom center of the tank running from there to the front of the tank(the end with the male fitting)with a gate valve for water draining, the tank will be capable of reading the fuel level from the ground outside the tank(external gauge mounted on the front of the tank(2.5"Diameter Minimum)) as well as a means of manual gauging(gauging hatch on the top of the tank)with a gauging chart,a manhole cover to allow access to the inside for cleaning purposes,steps to the top of the tank with a catwalk system and safety railing, the tank will have a maximum exterior size capable of fitting in the containment area allowing a minimum of 2.5 feet of clearence on the sides and 4 feet of clearence at either end,the tank will be capable of being lifted with a overhead crane, the tank, catwalk,railing, piping,etc is to be delivered painted a flat white. The tank(s) are to be delivered and setup in the containment area on Volk Field CRTC, Camp Douglas, WI,FOB point: Destination, Include a completed copy of FAR 52.212-3,Offeror Representations and Certifications -- Commercial Items, The clause FAR 52.212-4, Contract Terms and Conditions -- Commercial Items and FAR 52.212-5 Contract Terms and Conditions Required To Implement Statutes or Executive Orders -- Commercial Items applies to the quotation. This quotation will be evaluated using lowest price and past expirience as a bases for award.Offers are due on 25 FEB 99, 4:00 P.M. local time, at Base Contracting Office, 100 Independence Dr, Bldg 17, Camp Douglas, WI, 54618-5001. You may contact MSgt Neal Hause at (608)427-1235, Fax (608)427-1261. Posted 01/27/99 (W-SN292049). (0027)

Loren Data Corp. http://www.ld.com (SYN# 0233 19990129\54-0002.SOL)


54 - Prefabricated Structures and Scaffolding Index Page