|
COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 1,1999 PSA#2273National Institute of Standards & Technology, Acquisition & Assistance
Div.,100 Bureau Drive Stop 3572, Bldg. 301, Rm B117, Gaithersburg, MD
20899-3572 68 -- LIQUID NITROGEN 1500-GALLON STORAGE TANK SOL 53SBNB960020 DUE
021199 POC Anita K. Tolliver, Contract Specialist/Contracting Officer,
#301/975-6308; Fax #301/963-7732 WEB: NIST Contracts Homepage,
http://www.nist.gov/admin/od/contract.htm. E-MAIL: NIST Contracts
Office, Contract@nist.gov. THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR
COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN FAR SUBPART
12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS
NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTES ARE
BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED.
SOLICITATION NUMBER 53SBNB960020 IS BEING ISSUED AS A REQUEST FOR
QUOTATIONS (RFQ) USING SIMPLIFIED ACQUISITION PROCEDURES. Incorporated
provisions and clauses are those in effect through Federal Acquisition
Circular 97-09. The National Institute of Standards and Technology has
a requirement for one liquid nitrogen 1500-gallon (5678 liters)
storage tank including piping, installation and testing. The Contract
Line Item Numbers (CLIN), quantities, and unit issues are as follows:
CLIN 0001, Liquid Nitrogen 1500-gallon (5678 liters) storage tank with
the following specifications: 9% nickel inner vessel, carbon steel
outer vacuum shell, dual inner tank relief valve and rupture disc with
diverter valve, fill line check valve and drain valve, and vacuum
annulus rupture disc. The tank will remain outside and shall be
manufactured to withstand ambient weather conditions, excluding acts of
God, Qty. 1 each; CLIN 0002, Digital liquid level gauge which reads
gallons, inches, and percentage volume and shall be located at tank
site, Qty. 1 each; CLIN 0003, Omega Transducer: PX605-060GI (4-20 mA
output), Qty. 1 each; CLIN 0004, Digital liquid level gauge reads
gallons, inches, and percent volume and shall be located at the
experiment console. The experiment console is the command station for
operation of the Electron Beam Ion Trap which includes readouts of many
different experiment data values; Qty. 1 each; CLIN 0005, Line relief
valves, Qty. 2 each; CLIN 0006, Non-vacuum insulated valves shall be
bronze and approved for cryogenic service, Qty. 1 each; CLIN 0007,
Stainless steel interconnective piping provided to complete
installation; CLIN 0008, Copper extended fill line that shall be 1-1/2"
diameter with 2' support provided to complete installation; CLIN 0009,
Concrete pad with dimensions, 10' x 10' and a thickness of 12 inches
shall be provided for installing the tank, Qty. 1 each; CLIN 0010,
Corner posts shall be installed surrounding the tank, Qty. 4 each; CLIN
0011, Installation, Qty. 1 job. Installation of the tank, which
includes gauges, valves, piping, and the copper fill line shall be
conducted in accordance with manufacturer's specifications, Regulations
and Code as specified below. Installation shall also include the
installation and integration to existing vacuum insulated pipe
stainless steel liquid nitrogen horizontal transfer line with matching
bayonet. As part of the installation, the foundation site, drainage,
soil conditions, reinforcing bars, anchor bolts, concrete mix design
and concrete cover shall be completed in accordance with manufacturer's
specifications, Regulations and Code as specified below. All
penetrations made during installation shall be sealed to prevent
uncontained liquids, vapors, and gases from entering the Physics
Building, Number 221. Installation shall be completed as such that the
tank is fully installed and operational. While installation is
occurring, the Contractor shall ensure that the area where the work is
being performed is secured to protect the tank, installation site and
persons from harm. A site visit of the installation site is encouraged
prior to submission of your quote and the site visit shall be completed
by February 9, 1999. The provision 52.237-1, Site Visit applies to this
acquisition. Offerors or quoters are urged and expected to inspect the
site where services are to be performed and to satisfy themselves
regarding all general and local conditions that may affect the cost of
contract performance, to the extent that the information is reasonably
obtainable. Questions must be submitted in writing to Anita Tolliver.
In no event shall failure to inspect the site constitute grounds for a
claim after contract award. The installation site is located at
Physics Building, Number 221. The hours of access to the site are from
8:30 a.m. to 5:00 p.m. local time, Monday through Friday, excluding
holidays. A drawing of the proposed installation site is available by
faxing your request to Anita Tolliver at (301) 963-7732; CLIN 0012, An
8-foot chain-link fence with a swing gate shall be provided by the
Contractor and installed by the Contractor around the storage tank,
Qty. 1 each; CLIN 0013, Testing, Qty. 1 job. Initial testing shall
occur before, during, and after installation on system components
integrated to Ebit phase separator with stainless steel vacuum
insulated pipe segment, including physical, pressure, flow, current,
and volume measurements. All testing shall be performed by the
Contractor resulting in no downtime for the experiment. The Division
One Certification from the American Society of Mechanical Engineers
Boiler and Pressure Vessel Code, Section VIII shall be provided to NIST
as verification of the proper testing including: hydrostatic testing
certification, maximum recommended operating pressure and maximum
operating pressure; and stamping or nameplate. The Contractor shall
provide subsequent testing throughout the warranty period at the
Government's request; CLIN 0014, Vessel shall be placarded to indicate
the product. Qty. 1 each; CLIN 0015, All manuals and documentation
shall be provided to the Government including that which addresses
manufacturer's specifications; CLIN 0016, Warranty shall be three (3)
years on the vacuum storage tank and one (1) year on accessories. The
Contractor shall deliver all line items FOB Destination, to NIST,
Physics Building, Number 221 at the installation site, 100 Bureau
Drive, Gaithersburg, MD 20899-0001. Required delivery time is 60 days
after award and installation shall be completed within 30 days after
delivery. This requirement shall be fulfilled in accordance with
Regulations and Code of the following: the Compressed Gas Association's
Pamphlet V-6 (latest edition) regarding Standard Cryogenic Liquid
Transfer Connections and Pamphlet P-12 (latest edition) regarding the
Safe Handling of Cryogenic Liquids, Occupational Safety and Health
Association, National Electric Code and National Fire Protection
Agency. The provisions at 52.212-1, Instructions to Offerors-Commercial
Items, applies to this acquisition. The provision 52.212-2, Evaluation
of Commercial Items applies to this acquisition. The Government will
award a contract resulting from this solicitation to the responsible
offeror whose offer conforming to the solicitation will be most
advantageous to the Government, price and other factors considered. The
following factors shall be used to evaluate offers: 1) Technical
capability including the following sub-factors: performance
capabilities, operation, and system reliability; and 2) Past
performance including references. Price will be evaluated for
reasonableness. The Government requires a delivery time of 60 days
after award and the offeror shall indicate if they can meet this
delivery time. The clause at 52.212-4, Contract Terms and
Conditions-Commercial Items applies to this acquisition. The clause at
52.212-5, Contract Terms and Conditions Required to Implement Statutes
or Executive Orders-Commercial Items, applies to this acquisition,
including subparagraphs (9) 52.222-26, (10) 52.222-35, (11) 52.222-36,
(12) 52.222-37, (18)(i) 52.225-21 (Alternate I), and Department of
Commerce Agency-Level Protest Procedures Level Above the Contracting
Officer, download from the NIST Web Page located at
http://www.nist.gov/admin/od/contract/protest.htm. The following
clauses also apply to this acquisition: 52.237-2 Protection of
Government Buildings, Equipment, and Vegetation; and 52.228-5,
Insurance -- Work on a Government Installation. Pursuant to the clause
"Insurance -- Work on a Government Installation (FAR 52.228-5), "the
Contractor will be required to present evidence to show, as a minimum,
the following amounts of insurance coverage: (a) Workers Compensation
and Employer's Liability. The Contractor is required to comply with
applicable Federal and State worker's compensation and occupational
disease statutes. If occupational diseases are not compensable under
those statutes, they shall be covered under the employer's liability
section of the insurance policy, except when contract operations are so
commingled with a Contractor's commercial operations that it would not
be practical to require this coverage. Employer's liability coverage
of at least $100,000 shall be required, except in States with exclusive
or monopolistic funds that do not permit workers' compensation to be
written by private carriers. (b) General Liability: (1) The Contractor
shall have bodily injury liability insurance coverage written on the
comprehensive form of policy of at least $500,000 per occurrence. (2)
Property Damage liability insurance shall be required in the amount of
$100,000. (c) Automobile Liability. The Contractor shall have
automobile liability insurance written on the comprehensive form of
policy. The policy shall provide for bodily injury and property damage
liability covering the operation of all automobiles used in connection
with performing the contract. Policies Covering Automobiles operated in
the United States shall provide coverage of at least $200,000 per
person and $500,000 per occurrence for bodily injury and $20,000 per
occurrence for property damage. For this requirement, the applicable
Standard Industrial Classification Code is 5047 and the related small
business size standard is 500 employees, however, this requirement is
unrestricted. Offerors shall submit the following: 1) Three (3) copies
of their quotation which addresses CLINs 0001-0016; 2) Technical
description and/or product literature addressing performance
capabilities, operation, and system reliability; 3) Two (2) copies of
the most recent published price list(s); 4) A list of at least three
references for contracts/purchase orders completed within the past
three years for similar requirements. Please provide a contact name,
phone number, contract number, and a brief description of the contract;
and 5) A completed copy of the provision at 52.212-3, Offeror
Representations and Certifications-Commercial Items, download from
http://www.nist.gov/admin/od/contract/repcert.htm. All offers should be
sent to the National Institute of Standards and Technology, Acquisition
and Assistance Division, Attn: Anita K. Tolliver, Building 301, Room
B117, 100 Bureau Drive, Stop 3572 Gaithersburg, MD 20899-3572. For
information, call the POC identified above. Submission must be received
by 3:00 p.m. local time on February 11, 1999. Faxed offers will be
accepted to (301) 963-7732. Posted 01/28/99 (W-SN292443). (0028) Loren Data Corp. http://www.ld.com (SYN# 0302 19990201\68-0008.SOL)
68 - Chemicals and Chemical Products Index Page
|
|