Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 4,1999 PSA#2276

Bureau of Reclamation, Contracts Group, 1150 N. Curtis Road, Suite 100, Boise, Idaho 83706-1234

46 -- POTABLE WATER TREATMENT EQUIPMENT FOR GRAND COULEE DAM SOL 1425-99-SP-10-14360 DUE 040899 POC Contact Thomas M. Haynes, Contract Specialist 208-378-5034/D.Scott Shelley Contracting Officer 208-378-5111 WEB: Click here to contact Contract Specialist via e-mail, thaynes@pn.usbr.gov. The due date for proposals has been changed to 8 April, 1999. The Facility demand, previously listed as 5,000-gpd is corrected to maximum facility demand of 380,000-gpd. Design, Manufacture, Furnish, Install and Test Potable Water Treatment facilities capable of meeting Washington State Department of Health requirements for surface water (Lake Roosevelt) source. A Firm, Fixed Price Contract shall be awarded based on best value to the Government. Solicitation issue date is scheduled for 02/18/99. Proposal due date is 04/15/99. Award of contract is scheduled prior to 09/01/99. Offerors responding to this solicitation must provide information showing that they meet the small business size standard of 500-employees or less. The standard industrial classification code is 3589. Telephone requests for this solicitation will not be accepted, requests for this solicitation must be in writing: U.S. Bureau of Reclamation, Attn: PN-3708, 1150 North Curtis Road, Suite 100, Boise ID 83706-1234, by fax: (208) 378-5108, or by E-mail: thaynes@pn.usbr.gov. All Responsible sources are encouraged to submit a proposal. A Diatomaceous Earth (DE) filtration system that operates on demand is required. System shall be semi-automatic. Disinfection shall be post filtration. The government has only one source for the disinfection portion of this requirement. In accordance with FAR 6.302-1 the disinfection system shall be model SAL-80 manufactured by MIOX Corporation, 5500 Midway Park Place, Albuquerque, NM 87109, Telephone No. (505) 343-0090. The contractor shall design, furnish, and install detention tanks adequate to meet code requirements. System shall have fully integrated monitoring, and control capability. System shall provide suitable warning and alarm out-puts to facility SCADA system. Site restrictions include: 1. Dry' waste, suitable for disposal in landfills is acceptable, liquid waste streams requiring treatment before disposal must be minimized. 2. Maximum facility demand is 380,000-gpd. 3. Inlet pressure ranges from 100 to 135-psi. 4. System discharge shall be of 350-gpm, at 280-psi. 5. Facility will be enclosed within a 55-foot by 33-foot by 15-foot high area. 6. Equipment shall be skid-mounted with no individual foot-print larger than 15-feet by 20-feet. 7. System shall be simple and inexpensive to operate and maintain. Work includes design, manufacture, delivery, installation completed no later than 10/01/00, and operational testing and reports complete no later than 02/01/01. See Numbered Notes 1, and 26. Posted 02/02/99 (W-SN293647). (0033)

Loren Data Corp. http://www.ld.com (SYN# 0254 19990204\46-0001.SOL)


46 - Water Purification and Sewage Treatment Equipment Index Page