Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 8,1999 PSA#2278

HQ, INDUSTRIAL OPERATIONS COMMAND, ATTN AMSIO-ACI, BLDG 350 5TH FLOOR MIDDLE BAY, ROCK ISLAND IL 61299-6000

66 -- RETROFIT/UPGRADE OF CONTROL SOL DAAA09-99-B-3021 DUE 032699 POC Contract Specialist Carol A. Lofgren (309) 782-8664 E-mail: lofgrenc@ioc.army.mil FAX: (309) 782-4955 (Site Code DAAA09) E-MAIL: lofgrenc@ioc.army.mil, lofgrenc@ioc.army.mil. RIA SN: 662500X988099. Retrofit/Upgrade of existing control and UMESS-UX or equal software for one each CNC Coordinate Measuring Machine manufactured by Carl Zeiss, Inc., model PMC850, SN 74419 with 60847/75 controller, consisting of the following: new C90 controller cabling and standard operator panel; new Y-axis cable (120mm); new Z-axis cable (600mm); new X-axis cable (850mm); UMESS-UX or equal Universal Measurement Software with the following: UX1-Enhanced Result Presentation; UX2-Extended Form/Position Evaluation; UX3-Best Fit Function; UX4-CNC Data Converter; UX5-Autorun Automatic Operation; UX6-Contour Points; UX8-Catalog/Data Bank; UX10-Measuring Program Library; new computer consisting of, but not limited to the following: HP 715/100 LAN UX workstation; 100 Mhz PA-RISC Co-Processor, 32 MB ECC RAM, 121.8 MIPS, 2 Gbyte hard drive, 3.5 inch disk drive, keyboard, mouse centronics, (2) RS232-C, SE SCSI-2, IEEE 802.3, Ethernet ThickLAN (AUI), EISA-Slot UX-Runtime graphics license; 17" color monitor, 1280 x 1024 resolution or better; 1.3 Gbyte digital data storage tape drive backup; 1.3 Gbyte HP DDS tapes (box of 5); HP LaserJet 5 or equal printer with 4MB RAM and cable (12 ppm). The contractor shall perform accuracy verification, installation of retrofit, adjustment of drives and probing system and calibration of the coordinate measuring machine, and certify its accuracy. A preventative maintenance shall be performed/completed no more than 3 months prior to the retrofit. The retrofit shall be complete within 30 consecutive days from the start period to limit the machine down time. One complete set of technical data is required. 1 Each. FOB: Destination, Rock Island Arsenal, Rock Island, IL 61299-5000. Delivery time 120 days. Approximate issue date 25 Feb 99 with opening date 30 days from issue. Firms interested in receiving solicitation package should FAX (309) 782-4955 and include cage code, taxpayer identification number, and business size. All responsible sources may submit a bid which shall be considered by the agency. The proposed contract listed here is unrestricted. NOTICE: All contractors who provide goods/services to the Department of Defense (DoD) must be registered in the Central Contractors Register (CCR) to be awarded DoD contracts. Further information may be obtained through the Internet at http://www.acq.osd.mil/ec/faqs. The Internet site for registering in the CCR is: http://ccr.edi.disa.mil. If you do not have Internet access and want to register, you may contact the CCR Registration Assistance Center at 1-888-227-2423, customer service, and request the registration form and assistance packet for completion.***** Posted 02/04/99 (A-SN295309). (0035)

Loren Data Corp. http://www.ld.com (SYN# 0492 19990208\66-0027.SOL)


66 - Instruments and Laboratory Equipment Index Page