COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 8,1999 PSA#2278HQ, INDUSTRIAL OPERATIONS COMMAND, ATTN AMSIO-ACI, BLDG 350 5TH FLOOR
MIDDLE BAY, ROCK ISLAND IL 61299-6000 66 -- RETROFIT/UPGRADE OF CONTROL SOL DAAA09-99-B-3021 DUE 032699 POC
Contract Specialist Carol A. Lofgren (309) 782-8664 E-mail:
lofgrenc@ioc.army.mil FAX: (309) 782-4955 (Site Code DAAA09) E-MAIL:
lofgrenc@ioc.army.mil, lofgrenc@ioc.army.mil. RIA SN: 662500X988099.
Retrofit/Upgrade of existing control and UMESS-UX or equal software for
one each CNC Coordinate Measuring Machine manufactured by Carl Zeiss,
Inc., model PMC850, SN 74419 with 60847/75 controller, consisting of
the following: new C90 controller cabling and standard operator panel;
new Y-axis cable (120mm); new Z-axis cable (600mm); new X-axis cable
(850mm); UMESS-UX or equal Universal Measurement Software with the
following: UX1-Enhanced Result Presentation; UX2-Extended Form/Position
Evaluation; UX3-Best Fit Function; UX4-CNC Data Converter; UX5-Autorun
Automatic Operation; UX6-Contour Points; UX8-Catalog/Data Bank;
UX10-Measuring Program Library; new computer consisting of, but not
limited to the following: HP 715/100 LAN UX workstation; 100 Mhz
PA-RISC Co-Processor, 32 MB ECC RAM, 121.8 MIPS, 2 Gbyte hard drive,
3.5 inch disk drive, keyboard, mouse centronics, (2) RS232-C, SE
SCSI-2, IEEE 802.3, Ethernet ThickLAN (AUI), EISA-Slot UX-Runtime
graphics license; 17" color monitor, 1280 x 1024 resolution or better;
1.3 Gbyte digital data storage tape drive backup; 1.3 Gbyte HP DDS
tapes (box of 5); HP LaserJet 5 or equal printer with 4MB RAM and cable
(12 ppm). The contractor shall perform accuracy verification,
installation of retrofit, adjustment of drives and probing system and
calibration of the coordinate measuring machine, and certify its
accuracy. A preventative maintenance shall be performed/completed no
more than 3 months prior to the retrofit. The retrofit shall be
complete within 30 consecutive days from the start period to limit the
machine down time. One complete set of technical data is required. 1
Each. FOB: Destination, Rock Island Arsenal, Rock Island, IL
61299-5000. Delivery time 120 days. Approximate issue date 25 Feb 99
with opening date 30 days from issue. Firms interested in receiving
solicitation package should FAX (309) 782-4955 and include cage code,
taxpayer identification number, and business size. All responsible
sources may submit a bid which shall be considered by the agency. The
proposed contract listed here is unrestricted. NOTICE: All contractors
who provide goods/services to the Department of Defense (DoD) must be
registered in the Central Contractors Register (CCR) to be awarded DoD
contracts. Further information may be obtained through the Internet at
http://www.acq.osd.mil/ec/faqs. The Internet site for registering in
the CCR is: http://ccr.edi.disa.mil. If you do not have Internet access
and want to register, you may contact the CCR Registration Assistance
Center at 1-888-227-2423, customer service, and request the
registration form and assistance packet for completion.***** Posted
02/04/99 (A-SN295309). (0035) Loren Data Corp. http://www.ld.com (SYN# 0492 19990208\66-0027.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|