Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 8,1999 PSA#2278

Regional Officer in Charge of Contract, Pearl Harbor, NAVFACENGCOM (R110), 4262 Radford Drive, Honolulu, HI 96818-3296

Z -- SPECIAL PROJECT CONSTRUCTION PACKAGE: PROJECT A- UPGRADE BULK FUEL TANKS; PROJECT B- UPGRADE VALVE PITS PMRF, KAUAI, HAWAII SOL N62742-98-R-1372 DUE 031899 POC Ms. Roxanne Vannatta, Procurement Technician, Ms. Jane Nishiguchi, Contract Specialist, Telephone No. (808) 474-6325, Facsimile No. (808) 474-7316 The scope of work includes two Special Projects. Project A involves upgrading nine underground storage tanks and includes cleaning, inspecting coating of tank interiors, providing high level alarms, and incidental related work. Project B involves removal of existing plug valves, wooden valve pit covers, and portions of concrete valve pit walls; provisions of new plug valves, pit ladders, and aluminum valve pit frames, covers and doors; concrete patching; and incidental related work. TECHNICAL EVALUATION FACTORS: The following evaluation factors and subfactors shall be used to evaluate the technical proposals. The major factors are listed in order of importance. Factor "A" is more important than Factor "B". The subfactors within the major factors are of equal importance. a. FACTOR A. Past Performance/Qualifications/Experience: The following information shall be submitted for evaluation to establish satisfactory past performance and qualifications/experience: (1) For Project A: R5-95, Upgrade Bulk Fuel Storage Tanks: Contractor must have successfully completed projects that require all of the following: (a) Past performance of successful completion of cleaning, inspection, and interior painting of underground fuel tanks in the past five years. (b) Experience in Tank modification work including welding done in accordance with API 650 and API 653. (c) Successful application of modified PTFE-pigmented fluoropolyurethane coating system on the interior of fuel oil storage tank under conditions similar to this projects specifications. (d) Demonstrated effectiveness of Quality Control Program and Accident Prevention Plan for underground fuel oil tank work. (2) For Project B: R7-95, Upgrade Bulk Tank Farm Valve Pits: Contractor must have successfully completed projects that require all of the following: (a) Past performance of successful completion of fuel piping modification including replacement of valves in the past five years. (b) Demonstrated effectiveness of Quality Control Program and Accident Prevention Planfor fuel piping repair work, including welding in POL areas. (3) Offeror shall submit the following information for evaluation: (a) List of applicable projects (Government and/or Private) by contract number, title, description (include specific work performed as described in paragraphs 2.a.(1) and (2) above), award amount, completion amount, award date, completion date, point of contact name, phone number/fax number, and any other information regarding problems encountered and how resolved. (b) Copy of Experience Modification Worksheet (obtained from insurance company). (c) Customers' satisfaction of Contractor's work on similar projects demonstrated by letters of appreciation, commendations, and past performance evaluations. Note: Factor A, Past Performance history that relates to projects similar to this project will receive more favorable consideration than past history that are not related to this project. Therefore, the lack of performance history would not disqualify an offeror, but that, among other things, the offeror could be considered less favorably than an offeror with a favorable performance history. b. FACTOR B. Key Personnel: Contractor's employee(s), or subcontractor(s), will be evaluated for qualifications and experience in being assigned to this project for cleaning, repairing, and inspecting underground fuel tanks; painting of tank interior for underground tanks, inspection of tank coating; and tank modification work. Submit personnel employment history, education, qualifications and resume to include description of projects within the last five years. Projects similar to Projects A and B will receive more favorable consideration. Provide information for the following personnel: (1) Individual(s) who will perform the following tank work: cleaning, inspection, interior coating, and modification work. (2) Project Superintendent (3) Quality Control Manager (4) Safety Manager. The estimated cost is $500,000.-$1,000,000. This Request for Proposal (RFP) is unrestricted. The Standard Industry Classification (SIC) code is 1629 and the annual size is $17.0 M. THE RFP WILL BE AVAILABLE ON OR ABOUT 16 FEBRUARY 1999 AT A NON- REFUNDABLE CHARGE OF $70.04. SEND YOUR REQUEST FOR THE RFP TO: DEFENSE AUTOMATED PRINTING SERVICE, PO BOX 126, PEARL HARBOR, HAWAII 96860-5120. CHECKS SHALL BE MADE PAYABLE TO "SUPERINTENDENT OF DOCUMENTS." IF USING VISA, MASTERCARD OR DISCOVER, BE SURE TO INCLUDE THE CARDHOLDER'S NAME, ACCOUNT NUMBER AND EXPIRATION DATE IN YOUR LETTER. THE LETTER MUST ALSO STATE YOUR COMPANY NAME, ADDRESS, TELEPHONE NUMBER, FACSIMILE NUMBER, RFP NO. AND PROJECT TITLE, AND WHETHER THE RFP WILL BE PICKED UP AT REGIONAL OFFICER IN CHARGE OF CONTRACTS (ROICC), NAVFACENGCOM, CONSTRUCTION CONTRACTS DIVISION, 4262 RADFORD DRIVE, HONOLULU, HAWAII 96818-3296. Allow at least ten days for receipt of solicitation. Companies wanting the RFP to be sent via air express service must furnish their express service's airbill label with the recipient's name, telephone no., company name, address,company's account no., and type of delivery filled in. Failure to provide any of the above information and check, as indicated, may delay the processing of the RFP and is at no fault of the Government. INDIVIDUAL CHECKS AND REQUESTS ARE TO BE SUBMITTED FOR EACH SOLICITATION. Planholders list may be obtained from the DAPS web page at http://www.hawaii.wnbt.daps.mil. If unable to access through the web page, you may fax a request for planholders list to (808) 474-7316. NOTICE TO ALL SOLICITATIONS ISSUANCE: Any request for solicitation(s) received within 10 working days prior to the bid opening date or request for proposal closing date will be processed in accordance with the above procedures. However, there is no guarantee that the recipient will receive the solicitation prior to the bid opening date or proposal closing date. Posted 02/04/99 (W-SN295299). (0035)

Loren Data Corp. http://www.ld.com (SYN# 0181 19990208\Z-0027.SOL)


Z - Maintenance, Repair or Alteration of Real Property Index Page